PMWCS3 Capacitive Soil Moisture and Temperature Sensor ====================================================== .. seo:: :description: Instructions for setting up PMWCS3 capacitive soil moisture sensor in ESPHome. :image: pmwcs3.jpg :keywords: PMWCS3 The ``pmwcs3`` sensor platform allows you to use your PMWCS3 (`informations `__) capacitive soil moisture and temperature sensor with ESPHome. The :ref:`I²C bus ` is required to be set up in your configuration for this sensor to work. Wiring scheme: red is 3.3V, black & shield is GND, green is SDA and white is SCL. 2.2kOhm resistors are advised to pullup both SDA & SDA lines. .. figure:: images/pmwcs3.jpg :align: center :width: 80.0% PMWCS3 Capacitive Soil Moisture and Temperature Sensor. .. code-block:: yaml # Example configuration entry sensor: - platform: pmwcs3 e25: name: "pmwcs3 e25" ec: name: "pmwcs3 ec" temperature: name: "pmwcs3 temperature" vwc: name: "pmwcs3 vwc" Configuration variables: ------------------------ - **e25** (*Optional*): Electrical Conductivity, reference at 25°C in dS/m. All options from :ref:`Sensor `. - **ec** (*Optional*): Electrical Conductivity in mS/m. All options from :ref:`Sensor `. - **temperature** (*Optional*): Soil temperature in °C. All options from :ref:`Sensor `. - **vwc** (*Optional*): Volumetric Water Content in cm3cm−3. All options from :ref:`Sensor `. - **address** (*Optional*, int): Manually specify the I²C address of the sensor. Defaults to ``0x63``. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. .. _sensor-PMWCS3AirCalibrationAction: ``pmwcs3.air_calibration`` Action ----------------------------------- The pmwcs3 probe can to be calibrated in dry/air conditions. The air calibration is a 30s procedure. .. code-block:: yaml # Example configuration entry sensor: - platform: pmwcs3 id: pmwcs3_id # ... # in some trigger on_...: - sensor.pmwcs3_id.air_calibration: id: pmwcs3_id Configuration option: - **id** (**Required**, :ref:`config-id`): The ID of the pmwcs3 sensor. .. _sensor-PMWCS3WaterCalibrationAction: ``pmwcs3.water_calibration`` Action ----------------------------------- The pmwcs3 probe can to be also calibrated in water saturated conditions. Install the probe into a glass of water. The water calibration is also a 30s procedure. .. code-block:: yaml # Example configuration entry sensor: - platform: pmwcs3 id: pmwcs3_id # ... # in some trigger on_...: - sensor.pmwcs3_id.water_calibration: id: pmwcs3_id Configuration option: - **id** (**Required**, :ref:`config-id`): The ID of the pmwcs3 sensor. .. _sensor-PMWCS3NewI2cAddressAction: ``pmwcs3.new_i2c_address`` Action --------------------------------- A new I2C address can be set (for multi-probes cases for example) .. code-block:: yaml # Example configuration entry sensor: - platform: pmwcs3 id: pmwcs3_id # ... # in some trigger on_...: - sensor.pmwcs3_id.new_i2c_address: id: pmwcs3_id address: 0x65 Configuration options: - **id** (**Required**, :ref:`config-id`): The ID of the pmwcs3 sensor. - **address** (**Required**, int): New I2C address. See Also -------- - :ref:`sensor-filters` - :apiref:`pmwcs3/pmwcs3.h` - `Temperature Compensation for Conductivity `__ - `PMWCS3 Library `__ by `@tinovi `__ - :ghedit:`Edit`