CT Clamp Current Sensor ======================= .. seo:: :description: Instructions for setting up ct clamp sensors. :image: ct_clamp.jpg The Current Transformer Clamp (``ct_clamp``) sensor allows you to hook up a CT Clamp to an analog voltage sensor (like the :doc:`ADC sensor `) and convert the readings to measured single phase AC current. First, you need to set up a voltage sensor source (:doc:`ADC sensor `, but for example also :doc:`ADS1115 `) and pass it to the CT clamp sensor with the ``sensor`` option. Please also see `this guide `__ as an introduction to the working principle of CT clamp sensors and how to hook them up to your device. .. figure:: images/ct_clamp-ui.png :align: center :width: 80.0% .. code-block:: yaml # Example configuration entry sensor: - platform: ct_clamp sensor: adc_sensor name: "Measured Current" update_interval: 60s # Example source sensor - platform: adc pin: A0 id: adc_sensor Configuration variables: ------------------------ - **name** (**Required**, string): The name of the sensor. - **sensor** (**Required**, :ref:`config-id`): The source sensor to measure voltage values from. - **sample_duration** (*Optional*, :ref:`config-time`): The time duration to sample the current clamp with. Higher values can increase accuracy. Defaults to ``200ms`` which would be 10 whole cycles on a 50Hz system. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. The **update_interval** for ``ct_clamp`` has to be greater than **sample_duration**. - **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation. - All other options from :ref:`Sensor `. Calibration ----------- This sensor needs calibration to show correct values, for this you can use the :ref:`calibrate_linear ` sensor filter. First, hook up a known current load like a lamp that uses a known amount of current. Then switch it on and see what value the CT clamp sensor reports. For example in the configuration below a 4.0 A device is showing a value of 0.1333 in the logs. Now go into your configuration file .. code-block:: yaml # Example configuration entry sensor: - platform: ct_clamp sensor: adc_sensor name: "Measured Current" update_interval: 60s filters: - calibrate_linear: # Measured value of 0 maps to 0A - 0 -> 0 # Known load: 4.0A # Value shown in logs: 0.1333A - 0.1333 -> 4.0 Recompile and upload, now your CT clamp sensor is calibrated! See Also -------- - `EMonLib `__ - `CT Clamp Guide `__ - :doc:`adc` - :doc:`ads1115` - :apiref:`sensor/ct_clamp.h` - :ghedit:`Edit`