TMP117 Temperature Sensor ========================= .. seo:: :description: Instructions for setting up the TMP117 Temperature sensor. :image: tmp117.jpg :keywords: TMP117 The TMP117 Temperature sensor allows you to use your TMP117 (`datasheet `__, `sparkfun `__) sensors with ESPHome. .. figure:: images/tmp117.jpg :align: center :width: 30.0% TMP117 Temperature Sensor. (Credit: `Sparkfun `__, image cropped and compressed) .. _Sparkfun: https://www.sparkfun.com/products/15805 The TMP117 is a high precision temperature sensor that communicates over I²C. Each sensor is tested on a NIST tracable test setup during Texas Instruments' production process. Accuracy should be at worst 0.1C across the -20C to +50C temperature range. To use the sensor, first set up an :ref:`I²C Bus ` and connect the sensor to the specified pins. If accuracy is a must, see section 8.2.2.2 of the `datasheet `__. .. code-block:: yaml # Example configuration entry sensor: - platform: tmp117 name: "Living Room Temperature" update_interval: 60s Configuration variables: ------------------------ - **name** (**Required**, string): The name for the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for lambdas/multiple sensors. - **address** (*Optional*, int): The I²C address of the sensor. See :ref:`I²C Addresses ` for more information. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. The sensor component sets the maximum possible averaging in the sensor based on this. .. _tmp117_i2c_addresses: I²C Addresses ------------- In order to allow multiple sensors to be connected to the same I²C bus, the creators of this sensor hardware have included some options to change the i²c address. - If the address pin is pulled to GND, the address is ``0x48`` (Default). - If the address pin is pulled to VCC, the address is ``0x49``. - If the address pin is tied to SDA, the address is ``0x4A``. - If the address pin is tied to SCL, the address is ``0x4B``.