Tuya Number =========== .. seo:: :description: Instructions for setting up a Tuya device integer or enum datapoint.. :image: upload.svg The ``tuya`` number platform allows you to create a number that controls a tuya serial component. This platform requires :doc:`/components/tuya` to be configured. When :doc:`/components/tuya` has been properly configured, it will output a list of valid data points to the log after start-up. .. code-block:: text [21:37:14][C][tuya:028]: Tuya: [21:37:14][C][tuya:045]: Datapoint 101: enum (value: 4) [21:37:14][C][tuya:045]: Datapoint 102: enum (value: 1) [21:37:14][C][tuya:041]: Datapoint 103: int value (value: 5) [21:37:14][C][tuya:039]: Datapoint 104: switch (value: OFF) [21:37:14][C][tuya:041]: Datapoint 105: int value (value: 229) [21:37:14][C][tuya:041]: Datapoint 106: int value (value: 37) [21:37:14][C][tuya:041]: Datapoint 107: int value (value: 10) [21:37:14][C][tuya:041]: Datapoint 108: int value (value: 35) [21:37:14][C][tuya:041]: Datapoint 109: int value (value: 30) [21:37:14][C][tuya:041]: Datapoint 110: int value (value: 80) [21:37:14][C][tuya:039]: Datapoint 112: switch (value: OFF) [21:37:14][C][tuya:039]: Datapoint 113: switch (value: OFF) [21:37:14][C][tuya:039]: Datapoint 114: switch (value: OFF) [21:37:14][C][tuya:045]: Datapoint 115: enum (value: 4) [21:37:14][C][tuya:045]: Datapoint 116: enum (value: 2) [21:37:14][C][tuya:055]: Product: '{"p":"ymf4oruxqx0xlogp","v":"1.0.3","m":0}' The example output above from a Tuya Siren with temperature and humidity sensors. The ``tuya`` number platform can be used to control all of the integer and enum datapoints. On this device, datapoint 116 represents the volume control, with valid values being 0=High, 1=Medium, 2=Low. Based on this, you can create a number as follows: .. code-block:: yaml - platform: "tuya" name: "Volume" number_datapoint: 116 min_value: 0 max_value: 2 step: 1 Configuration variables: ------------------------ - **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation. - **name** (**Required**, string): The name of the switch. - **number_datapoint** (**Required**, int): The datapoint id number of the number. - **min_value** (**Required**, float): The minimum value this number can be. - **max_value** (**Required**, float): The maximum value this number can be. - **step** (**Required**, float): The granularity with which the number can be set. - All other options from :ref:`Number `. See Also -------- - :doc:`/components/number/index` - :apiref:`tuya/number/tuya_number.h` - :ghedit:`Edit`