Pulse Meter Sensor ================== .. seo:: :description: Instructions for setting up pulse meter sensors. :image: pulse.png The pulse meter sensor allows you to count the number and frequency of pulses on any pin. It is intended to be a drop-in replacement for :doc:`integration sensor `, but offering better resolution. It measures the time between rising edges on a pin, for each pulse it outputs the frequency in pulses/min. .. code-block:: yaml # Example configuration entry sensor: - platform: pulse_meter pin: 12 name: "Pulse Meter" Configuration variables: ------------------------ - **pin** (**Required**, :ref:`config-pin`): The pin to count pulses on. - **name** (**Required**, string): The name of the sensor. - **internal_filter** (*Optional*, :ref:`config-time`): If a pulse shorter than this time is detected, it’s discarded and no pulse is counted. Defaults to ``13us``. For S0 pulse meters that are used to meter power consumption 50-100 ms is a reasonable value. - **timeout** (*Optional*, :ref:`config-time`): If we don't see a pulse for this length of time, we assume 0 pulses/sec. Defaults to ``5 min``. - **total** (*Optional*, :ref:`Sensor `): An additional sensor that outputs the total number of pulses counted. - All other options from :ref:`Sensor `. Converting units ---------------- The sensor defaults to units of “pulses/min”. You can change this by using :ref:`sensor-filters`. For example, if you’re using the pulse meter with a photodiode to count the light pulses on a power meter that outputs 1000 pulses per kWh, you can use the following to output instantaneous usage in kW: .. code-block:: yaml # Example configuration entry sensor: - platform: pulse_meter pin: 12 unit_of_measurement: 'kW' name: 'Electricity Usage' filters: - multiply: 0.06 Counting total pulses --------------------- When the total sensor is configured, pulse_meter also reports the total number of pulses measured. When used on a power meter, this can be used to measure the total consumed energy in kWh. .. code-block:: yaml # Example configuration entry sensor: - platform: pulse_meter pin: 12 unit_of_measurement: 'kW' name: 'Electricity Usage' filters: - multiply: 0.06 total: name: "Electricity Total" unit_of_measurement: "kWh" accuracy_decimals: 0 filters: - multiply: 0.001 See Also -------- - :ref:`sensor-filters` - :doc:`/components/sensor/pulse_counter` - :apiref:`pulse_meter/pulse_meter_sensor.h` - :ghedit:`Edit`