TMP1075 Temperature Sensor ========================== .. seo:: :description: Instructions for setting up the TMP1075 Temperature sensor. :image: tmp1075.jpg :keywords: TMP1075 The TMP1075 Temperature sensor allows you to use your TMP1075 (`datasheet `__) sensors with ESPHome. .. figure:: images/tmp1075.jpg :align: center :width: 30.0% TMP1075 Temperature Sensor. (Credit: `Texas Instruments `__, image cropped and compressed) The TMP1075 is a high precision temperature sensor that communicates over I²C. Each sensor is tested on a NIST tracable test setup during Texas Instruments' production process. Accuracy is typically ±0.25°C across the -55°C to +125°C range, with a maximum error of ±2°C in that same range and ±1°C in the -40°C to +110°C range. To use the sensor, first set up an :ref:`I²C Bus ` and connect the sensor to the specified pins. .. code-block:: yaml # Example configuration entry sensor: - platform: tmp1075 name: "Temperature TMP1075" update_interval: 10s i2c_id: i2c_bus conversion_rate: 27.5ms alert: function: comparator polarity: active_high limit_low: 50 limit_high: 75 fault_count: 1 Configuration variables: ------------------------ - **name** (**Required**, string): The name for the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for lambdas/multiple sensors. - **address** (*Optional*, int): The I²C address of the sensor. See :ref:`I²C Addresses ` for more information. Defaults to ``0x48``. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor temperature. Defaults to ``60s``. - **conversion_rate** (*Optional*): The interval at which the IC performs a temperature measurement. This setting also determines how fast the alert pin responds to temperature changes, and is thus independent of how often ESPHome checks the sensor. Possible values are ``27.5ms``, ``55ms``, ``110ms``, and ``220ms``. Defaults to ``27.5ms``. - **alert** (*Optional*): Configure the alert pin behaviour. - **function** (*Optional*, enum): Function of the alert pin, either ``comparator`` or ``interrupt``. Defaults to ``comparator``. - **polarity** (*Optional*, enum): Polarity of the alert pin, either ``active_high`` or ``active_low``. Defaults to ``active_high``. - **limit_low** (*Optional*, int): Lower temperature limit, in °C. Defaults to ``-128`` (the lowest possible limit value). - **limit_high** (*Optional*, int): Higher temperature limit, in °C. Defaults to ``127.9375`` (the highest possible limit value). - **fault_count** (*Optional*, int): Number of measurements. required for the alert pin to act. Must be between ``1`` and ``4``, inclusive. Defaults to ``1``. .. _tmp1075_i2c_addresses: I²C Addresses ------------- In order to allow multiple sensors to be connected to the same I²C bus, the creators of this sensor hardware have included some options to change the I²C address. Three address pins can be connected to GND, VCC, SDA, or SCL, creating 32 possible addresses. See section 9.3.2.2 of the `datasheet `__ for the mapping table. When all address pins are connected to GND, the address is ``0x48``, which is the default address for this sesnsor component.