The Grove - Laser PM2.5 Sensor (HM3301) ======================================= .. seo:: :description: Instructions for setting up HM3301 Particulate matter sensor :image: hm3301.png The ``HM3301`` sensor platform allows you to use your HM3301 particulate matter sensor (`more info `__) sensors with ESPHome. The sensor communicate with board by :ref:`I²C ` protocol, and requires 3.3v. .. code-block:: yaml # Example configuration entry i2c: sensor: - platform: hm3301 pm_1_0: name: "PM1.0" pm_2_5: name: "PM2.5" pm_10_0: name: "PM10.0" aqi: name: "AQI" calculation_type: "CAQI" Configuration variables: ------------------------ - **pm_1_0** (*Optional*): Use the concentration of particulates of size less than 1.0µm in µg per cubic meter. - **name** (**Required**, string): The name for the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **pm_2_5** (*Optional*): Use the concentration of particulates of size less than 2.5µm in µg per cubic meter. - **name** (**Required**, string): The name for the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **pm_10_0** (*Optional*): Use the concentration of particulates of size less than 10.0µm in µg per cubic meter. - **name** (**Required**, string): The name for the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **aqi** (*Optional*): AQI sensor. Requires the ``pm_2_5`` and ``pm_10_0`` sensors defined. See below. - **calculation_type** (**Required**): One of: ``AQI`` or ``CAQI``. - **name** (**Required**, string): The name for the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. Air Quality Sensor: ------------------- There is a sensor which calculates quality of air based on PM 2.5 and PM 10.0 values. There are two implementations: - AQI: USA air quality standard - CAQI: Europe air quality standard .. code-block:: yaml sensor: - platform: hm3301 pm_2_5: name: "PM2.5" pm_10_0: name: "PM10.0" aqi: name: "AQI" calculation_type: "CAQI" See Also -------- - :doc:`/components/sensor/sds011` - :ref:`sensor-filters` - :apiref:`hm3301/hm3301.h` - :ghedit:`Edit`