mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-12-27 17:37:45 +01:00
198 lines
6.5 KiB
ReStructuredText
198 lines
6.5 KiB
ReStructuredText
Pylontech Battery
|
|
=================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up Pylontech Battery in ESPHome.
|
|
:image: pylontech.jpg
|
|
|
|
The Pylontech component allows you to pull data from Pylontech Batteries into ESPHome.
|
|
It uses :ref:`UART <uart>` for communication.
|
|
|
|
Once configured, you can use sensors as described below for your projects.
|
|
|
|
.. figure:: images/pylontech.jpg
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
Pylontech Batteries
|
|
|
|
Hardware Setup
|
|
--------------
|
|
|
|
You can connect to Pylontech Batteries using the port labeled "Console".
|
|
Any connections via CAN or RS485 (e.g. to an inverter) are untouched and remain functional.
|
|
|
|
The console port offers a RS232 interface using a RJ10 or RJ45 connector.
|
|
The voltage levels are *not* TTL-compatible. A RS232 transceiver must be placed between the Batteries and the ESPHome device.
|
|
MAX3232-based transceivers have been tested and work well.
|
|
|
|
If you have multiple batteries you need to connect to the master battery's console port.
|
|
|
|
.. list-table:: Pylontech RJ45 Console Port (US2000C, US3000C)
|
|
:header-rows: 1
|
|
|
|
* - RJ45 Pin
|
|
- Function
|
|
- Connect to
|
|
* - 3
|
|
- Pylontech TX
|
|
- ESPHome RX via transceiver
|
|
* - 6
|
|
- Pylontech RX
|
|
- ESPHome TX via transceiver
|
|
* - 8
|
|
- GND
|
|
- GND
|
|
|
|
.. figure:: images/rj45_pinout.jpg
|
|
:align: center
|
|
:width: 70.0%
|
|
|
|
RJ45 pinout
|
|
|
|
.. list-table:: Pylontech RJ10 Console Pinout (US2000B)
|
|
:header-rows: 1
|
|
|
|
* - RJ410 Pin
|
|
- Function
|
|
- Connect to
|
|
* - 2
|
|
- Pylontech RX
|
|
- ESPHome TX via transceiver
|
|
* - 3
|
|
- Pylontech TX
|
|
- ESPHome RX via transceiver
|
|
* - 4
|
|
- GND
|
|
- GND
|
|
|
|
Component/Hub
|
|
-------------
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
pylontech:
|
|
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- **id** (**Required**, :ref:`config-id`): The id to use for this Pylontech component.
|
|
- **uart_id** (*Optional*): The uart Bus ID
|
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
|
|
|
Sensor
|
|
------
|
|
|
|
All values are reported for every Pylontech battery individually.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: pylontech
|
|
battery: 1
|
|
|
|
voltage:
|
|
name: "Battery1 Voltage"
|
|
current:
|
|
name: "Battery1 Current"
|
|
coulomb:
|
|
name: "Battery1 State of Charge"
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- **pylontech_id** (*Optional*): Manually specify the ID of the pylontech instance if there are multiple.
|
|
- **battery** (**Required**): Which battery to monitor. 1 stands for the main battery, 2..6 for child batteries.
|
|
- **voltage** (*Optional*): Voltage of the battery. All options from :ref:`Sensor <config-sensor>`.
|
|
- **current** (*Optional*): Current flowing into the battery. Negative when discharging. All options from :ref:`Sensor <config-sensor>`.
|
|
- **coulomb** (*Optional*): State of Charge in percent. All options from :ref:`Sensor <config-sensor>`.
|
|
- **temperature** (*Optional*): Temperature. All options from :ref:`Sensor <config-sensor>`.
|
|
- **temperature_low** (*Optional*): Historic minimum temperature. All options from :ref:`Sensor <config-sensor>`.
|
|
- **temperature_high** (*Optional*): Historic maximum temperature. All options from :ref:`Sensor <config-sensor>`.
|
|
- **voltage_low** (*Optional*): Voltage of the lowest cell. All options from :ref:`Sensor <config-sensor>`.
|
|
- **voltage_high** (*Optional*): Voltage of the highest cell. All options from :ref:`Sensor <config-sensor>`.
|
|
- **mos_temperature** (*Optional*): Temperature of the mosfets. All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
Text Sensor
|
|
-----------
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
text_sensor:
|
|
- platform: pylontech
|
|
pylontech_id: pylontech0
|
|
battery: 1
|
|
|
|
base_state:
|
|
id: bat1_base_state
|
|
name: "Battery1 Base State"
|
|
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- **pylontech_id** (**Optional**): Manually specify the ID of the pylontech instance if there are multiple.
|
|
- **battery** (**Required**): Which battery to monitor. 1 stands for the main battery, 2..6 for child batteries.
|
|
- **base_state** (*Optional*): Base state. Usually reads ``Dischg``, ``Charge`` or ``Idle``. All options from :ref:`Text Sensor <config-text_sensor>`.
|
|
- **voltage_state** (*Optional*): Voltage state. Usually reads ``Normal``. All options from :ref:`Text Sensor <config-text_sensor>`.
|
|
- **current_state** (*Optional*): Current state. Usually reads ``Normal``. All options from :ref:`Text Sensor <config-text_sensor>`.
|
|
- **temperature_state** (*Optional*): Temperature state. Usually reads ``Normal``. All options from :ref:`Text Sensor <config-text_sensor>`.
|
|
|
|
Energy Monitoring
|
|
-----------------
|
|
|
|
By combining :doc:`template sensors </components/sensor/template>` and :doc:`integration sensors </components/sensor/integration>`
|
|
one can monitor the energy flowing into and out of all batteries combined, ready for `Homeassistant Energy Monitoring <https://www.home-assistant.io/docs/energy/battery/>`__.
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
- platform: template
|
|
id: pylontech_power
|
|
name: "Pylontech power"
|
|
unit_of_measurement: W
|
|
lambda: |-
|
|
auto pwr1 = id(bat1_voltage).state * id(bat1_current).state;
|
|
auto pwr2 = id(bat2_voltage).state * id(bat2_current).state;
|
|
auto pwr = pwr1 + pwr2;
|
|
id(combined_charge_power).publish_state(max(pwr, 0.0f));
|
|
id(combined_discharge_power).publish_state(max(-pwr, 0.0f));
|
|
return pwr;
|
|
update_interval: 5s
|
|
device_class: power
|
|
state_class: measurement
|
|
|
|
- platform: template
|
|
id: combined_charge_power
|
|
|
|
- platform: template
|
|
id: combined_discharge_power
|
|
|
|
- platform: integration
|
|
name: "Pylontech charging"
|
|
sensor: combined_charge_power
|
|
time_unit: h
|
|
state_class: total_increasing
|
|
device_class: energy
|
|
unit_of_measurement: "Wh"
|
|
|
|
- platform: integration
|
|
name: "Pylontech discharging"
|
|
sensor: combined_discharge_power
|
|
time_unit: h
|
|
state_class: total_increasing
|
|
device_class: energy
|
|
unit_of_measurement: "Wh"
|
|
|
|
See Also
|
|
--------
|
|
|
|
- `Pylontech-Battery-Monitoring <https://github.com/irekzielinski/Pylontech-Battery-Monitoring>`__
|
|
- `nodered-pylontech-console-reader <https://github.com/juanhaywood/nodered-pylontech-console-reader>`__
|
|
- :ref:`uart`
|
|
- :ghedit:`Edit`
|