mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-12-30 18:09:26 +01:00
425 lines
18 KiB
ReStructuredText
425 lines
18 KiB
ReStructuredText
DSMR Component
|
||
==============
|
||
|
||
.. seo::
|
||
:description: Instructions for setting up DSMR Meter component in ESPHome.
|
||
:image: dsmr.svg
|
||
|
||
Component/Hub
|
||
-------------
|
||
|
||
The DSMR component connects to Dutch Smart Meters which comply to DSMR (Dutch Smart Meter
|
||
Requirements), also known as ‘Slimme meter’ or ‘P1 port’.
|
||
|
||
This integration supports plain non encrypted telegrams and also encrypted as used in Luxembourg.
|
||
In case your equipment has encryption you must get a 32 character long encryption key from your energy company.
|
||
|
||
This component is passive, it does not transmit any data to your equipment, the equipment always transmits
|
||
data which this component decodes and updates the configured sensors at the pace the data is received.
|
||
|
||
- For official information about DSMR refer to: `DSMR Document <https://www.netbeheernederland.nl/dossiers/slimme-meter-15>`__
|
||
- For official information about the P1 port refer to: `P1 Companion Standard <https://www.netbeheernederland.nl/_upload/Files/Slimme_meter_15_a727fce1f1.pdf>`__
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Example configuration entry
|
||
dsmr:
|
||
decryption_key: !secret decryption_key
|
||
|
||
sensor:
|
||
- platform: dsmr
|
||
energy_delivered_tariff1:
|
||
name: Energy Consumed Tariff 1
|
||
|
||
text_sensor:
|
||
- platform: dsmr
|
||
identification:
|
||
name: "DSMR Identification"
|
||
p1_version:
|
||
name: "DSMR Version"
|
||
|
||
|
||
Configuration variables:
|
||
|
||
- **decryption_key** (*Optional*, string, :ref:`templatable <config-templatable>`, 32 characters, case insensitive): The key to decrypt the
|
||
telegrams. Used in Lux only.
|
||
- **gas_mbus_id** (*Optional*, int): The id of the gas meter. Defaults to ``1``.
|
||
- **crc_check** (*Optional*, boolean): Specifies if the CRC check must be done. This is required to be set to false for
|
||
older DSMR versions as they do not provide a CRC. Defaults to ``true``.
|
||
- **max_telegram_length** (*Optional*, integer): The size of the buffer used for reading DSMR telegrams. Increase
|
||
if you are reading from a smart meter that sends large telegrams. Defaults to ``1500``.
|
||
- **uart_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the UART hub.
|
||
- **request_pin** (*Optional*, :ref:`Pin Schema <config-pin_schema>`): The pin that can be used for controlling
|
||
the P1 port's Data Request pin. Defaults to not using a Data Request pin.
|
||
See :ref:`Using the P1 Data Request pin <sensor-dsmr-request_pin>`.
|
||
- **request_interval** (*Optional*, :ref:`config-time`): The minimum time between two telegram readings.
|
||
Defaults to ``0ms``, meaning that the pace at which the smart meter sends its data determines the update frequency.
|
||
This works best in combination with a ``request_pin``, but this option will work without one too.
|
||
- **receive_timeout** (*Optional*, :ref:`config-time`): The timeout on incoming data while reading a telegram.
|
||
When no new data arrive within the given timeout, the device will consider the current telegram a loss and
|
||
starts looking for the header of the next telegram. Defaults to ``200ms``.
|
||
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID of the DSMR if you have multiple components.
|
||
|
||
Sensor
|
||
------
|
||
|
||
.. note:: Not all sensors are available on all devices.
|
||
|
||
Country specific sensors are listed last.
|
||
|
||
Configuration variables:
|
||
|
||
- **energy_delivered_tariff1** (*Optional*): Energy Consumed Tariff 1.
|
||
|
||
- **name** (**Required**, string): The name for the energy_delivered_tariff1 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **energy_delivered_tariff2** (*Optional*): Energy Consumed Tariff 2.
|
||
|
||
- **name** (**Required**, string): The name for the energy_delivered_tariff2 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **energy_returned_tariff1** (*Optional*): Energy Produced Tariff 1.
|
||
|
||
- **name** (**Required**, string): The name for the energy_returned_tariff1 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **energy_returned_tariff2** (*Optional*): Energy Produced Tariff 2.
|
||
|
||
- **name** (**Required**, string): The name for the energy_returned_tariff2 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **power_delivered** (*Optional*): Power Consumed.
|
||
|
||
- **name** (**Required**, string): The name for the power_delivered sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **power_returned** (*Optional*): Power Produced.
|
||
|
||
- **name** (**Required**, string): The name for the power_returned sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **electricity_failures** (*Optional*): Electricity Failures.
|
||
|
||
- **name** (**Required**, string): The name for the electricity_failures sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **electricity_long_failures** (*Optional*): Long Electricity Failures.
|
||
|
||
- **name** (**Required**, string): The name for the electricity_long_failures sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **voltage_l1** (*Optional*): Voltage Phase 1.
|
||
|
||
- **name** (**Required**, string): The name for the voltage_l1 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **voltage_l2** (*Optional*): Voltage Phase 2.
|
||
|
||
- **name** (**Required**, string): The name for the voltage_l2 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **voltage_l3** (*Optional*): Voltage Phase 3.
|
||
|
||
- **name** (**Required**, string): The name for the voltage_l3 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **current_l1** (*Optional*): Current Phase 1.
|
||
|
||
- **name** (**Required**, string): The name for the current_l1 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **current_l2** (*Optional*): Current Phase 2.
|
||
|
||
- **name** (**Required**, string): The name for the current_l2 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **current_l3** (*Optional*): Current Phase 3.
|
||
|
||
- **name** (**Required**, string): The name for the current_l3 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **power_delivered_l1** (*Optional*): Power Consumed Phase 1.
|
||
|
||
- **name** (**Required**, string): The name for the power_delivered_l1 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **power_delivered_l2** (*Optional*): Power Consumed Phase 2.
|
||
|
||
- **name** (**Required**, string): The name for the power_delivered_l2 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **power_delivered_l3** (*Optional*): Power Consumed Phase 3.
|
||
|
||
- **name** (**Required**, string): The name for the power_delivered_l3 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **power_returned_l1** (*Optional*): Power Produced Phase 1.
|
||
|
||
- **name** (**Required**, string): The name for the power_returned_l1 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **power_returned_l2** (*Optional*): Power Produced Phase 2.
|
||
|
||
- **name** (**Required**, string): The name for the power_returned_l2 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **power_returned_l3** (*Optional*): Power Produced Phase 3.
|
||
|
||
- **name** (**Required**, string): The name for the power_returned_l3 sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **gas_delivered** (*Optional*): Gas Consumed.
|
||
|
||
- **name** (**Required**, string): The name for the gas_delivered sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
Belgium
|
||
|
||
- **gas_delivered_be** (*Optional*): Gas Consumed Belgium.
|
||
|
||
- **name** (**Required**, string): The name for the gas_delivered_be sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
Luxembourg
|
||
|
||
- **energy_delivered_lux** (*Optional*): Energy Consumed Luxembourg
|
||
|
||
- **name** (**Required**, string): The name for the energy_delivered_lux sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
- **energy_returned_lux** (*Optional*): Energy Produced Luxembourg
|
||
|
||
- **name** (**Required**, string): The name for the energy_returned_lux sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
Text Sensor
|
||
-----------
|
||
|
||
Configuration variables:
|
||
|
||
- **identification** (*Optional*): DSMR Identification
|
||
|
||
- **name** (**Required**, string): The name for the identification text sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **p1_version** (*Optional*): DSMR Version
|
||
|
||
- **name** (**Required**, string): The name for the p1_version text sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **timestamp** (*Optional*): Timestamp
|
||
|
||
- **name** (**Required**, string): The name for the timestamp sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **electricity_tariff** (*Optional*): The current tariff. According to the specs value
|
||
'0001' means 'normal tariff' and value '0002' means 'low tariff'. Your meter may report differently.
|
||
|
||
- **name** (**Required**, string): The name for the electricity_tariff sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **electricity_failure_log** (*Optional*): Electricity Failure Log
|
||
|
||
- **name** (**Required**, string): The name for the electricity_failure_log sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **message_short** (*Optional*): Message Short
|
||
|
||
- **name** (**Required**, string): The name for the message_short sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **message_long** (*Optional*): Message Long
|
||
|
||
- **name** (**Required**, string): The name for the message_long sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **gas_equipment_id** (*Optional*): Gas Equipment ID.
|
||
|
||
- **name** (**Required**, string): The name for the gas_equipment_id sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **water_equipment_id** (*Optional*): Water Equipment ID
|
||
|
||
- **name** (**Required**, string): The name for the water_equipment_id sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **sub_equipment_id** (*Optional*): Sub Equipment ID
|
||
|
||
- **name** (**Required**, string): The name for the sub_equipment_id sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
- **gas_delivered_text** (*Optional*): A text sensor which unformatted gas data. You need to
|
||
apply a custom parsing of this value depending on your meter format.
|
||
|
||
- **name** (**Required**, string): The name for the p1_version text sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
Belgium
|
||
|
||
- **p1_version_be** (*Optional*): DSMR Version Belgium
|
||
|
||
- **name** (**Required**, string): The name for the p1_version_be text sensor.
|
||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||
|
||
Older DSMR meters support
|
||
-------------------------
|
||
|
||
Version 2.2 is supported with the following configuration:
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Custom uart settings for DSMR v2.2
|
||
uart:
|
||
baud_rate: 9600
|
||
data_bits: 7
|
||
parity: NONE
|
||
stop_bits: 1
|
||
|
||
dsmr:
|
||
crc_check: false
|
||
|
||
sensor:
|
||
- platform: dsmr
|
||
energy_delivered_tariff1:
|
||
name: dsmr_energy_delivered_tariff1
|
||
energy_delivered_lux:
|
||
name: dsmr_energy_delivered_tarifflux
|
||
|
||
text_sensor:
|
||
- platform: dsmr
|
||
identification:
|
||
name: "dsmr_identification"
|
||
p1_version:
|
||
name: "dsmr_p1_version"
|
||
gas_delivered_text:
|
||
name: "gas delivered raw"
|
||
|
||
|
||
.. _sensor-dsmr-request_pin:
|
||
|
||
P1 Data Request pin
|
||
-------------------
|
||
|
||
From the P1 companion guide: The P1 port is activated (start sending data) by setting "Data Request" line high
|
||
(to +5V). While receiving data, the requesting OSM must keep the "Data Request" line activated (set to +5V).
|
||
To stop receiving data OSM needs to drop "Data Request" line (set it to "high impedance" mode). Data transfer
|
||
will stop immediately in such case.
|
||
|
||
**Advantages when using a request pin:**
|
||
|
||
- After reading a telegram, the dsmr component will stop the data transfer until the telegram has been
|
||
fully processed. This separates retrieving and processing data and can thus be seen as a form of
|
||
hardware flow control.
|
||
- The interval at which sensor readings must be updated can be controlled cleanly by only starting a data
|
||
transfer when needed. This configuration option ``request_interval`` can be used to define this interval.
|
||
|
||
**Required hardware support**
|
||
|
||
Many DSMR reader circuits link the +5V pin of the P1 port directly to its Data Request pin. Doing this will
|
||
make the smart meter send telegrams at a pace as defined by the smart meter firmware. For example many
|
||
DSMR v5 meters will send a telegram every second.
|
||
*Circuits that use this type of wiring cannot make use of the* ``request_pin`` *option.*
|
||
|
||
However, when a circuit is used that allows switching the Data Request pin between +5V and high impedance
|
||
mode from a GPIO, then this GPIO can be configured as the ``request_pin``.
|
||
|
||
Best results have been achieved by using an optocoupler circuit to handle the switching. Direct GPIO output
|
||
or a transistor-based circuit are not feasible options. Here's an example circuit design:
|
||
|
||
.. figure:: images/dsmr-request-pin-circuit-example.png
|
||
|
||
.. _sensor-dsmr-improving_reader_results:
|
||
|
||
Improving reader results
|
||
------------------------
|
||
|
||
When telegrams are sometimes missed or when you get a lot of CRC errors, then you might have to do some
|
||
changes to get better reader results.
|
||
|
||
It is recommended to set the ``rx_buffer_size`` option of the UART bus to at least the maximum telegram size,
|
||
which defaults to 1500 bytes. The default UART read buffer is quite small an can easily overflow, causing
|
||
bytes of data getting lost.
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Example configuration
|
||
uart:
|
||
pin: D7
|
||
baud_rate: 115200
|
||
rx_buffer_size: 1700
|
||
|
||
dsmr:
|
||
max_telegram_length: 1700
|
||
|
||
It's best when a hardware UART is used for reading the P1 data. Whether or not hardware UART is used can
|
||
be checked in the config dump that you get when connecting to the API logger. Example logging output:
|
||
|
||
.. code-block:: text
|
||
|
||
[02:38:37][C][uart.arduino_esp8266:095]: UART Bus:
|
||
[02:38:37][C][uart.arduino_esp8266:097]: RX Pin: GPIO13
|
||
[02:38:37][C][uart.arduino_esp8266:099]: RX Buffer Size: 1500
|
||
[02:38:37][C][uart.arduino_esp8266:101]: Baud Rate: 115200 baud
|
||
[02:38:37][C][uart.arduino_esp8266:102]: Data Bits: 8
|
||
[02:38:37][C][uart.arduino_esp8266:103]: Parity: NONE
|
||
[02:38:37][C][uart.arduino_esp8266:104]: Stop bits: 1
|
||
[02:38:37][C][uart.arduino_esp8266:106]: Using hardware serial interface.
|
||
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||
|
||
When using an ESP8266, then GPIO13 (e.g. pin D7 on a D1 Mini) can be used for hardware RX. However, to
|
||
actually make it work, serial logging must be disabled to keep the hardware UART available for D7.
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Example configuration for ESP8266
|
||
logger:
|
||
baud_rate: 0
|
||
level: DEBUG
|
||
|
||
uart:
|
||
pin: GPIO13
|
||
baud_rate: 115200
|
||
|
||
See Also
|
||
--------
|
||
|
||
- :apiref:`dsmr/dsmr.h`
|
||
- :ghedit:`Edit`
|