TCL112 Remote Climate
=====================
.. seo::
:description: Controls a TCL112-compatible Climate via IR
:image: air-conditioner.png
The ``tcl112`` climate platform allows you to control a TCL112-compatible AC unit by sending IR signals
as your remote unit would do.
This component requires that you have setup a :doc:`/components/remote_transmitter`.
Due to the unidirectional nature of IR remote controllers, this component cannot determine the
actual state of the device, and will assume the state of the device is the latest state requested.
.. figure:: images/climate-ui.png
:align: center
:width: 60.0%
.. code-block:: yaml
# Example configuration entry
remote_transmitter:
pin: GPIO32
carrier_duty_percent: 50%
climate:
- platform: tcl112
name: "Living Room AC"
Configuration variables:
------------------------
- **name** (**Required**, string): The name for the climate.
- **supports_cool** (*Optional*, boolean): Enables setting cool mode for this climate device. Defaults to ``True``.
- **supports_heat** (*Optional*, boolean): Enables setting heat mode for this climate device. Defaults to ``True``.
- **sensor** (*Optional*, :ref:`config-id`): The sensor that is used to measure the ambient
temperature. This is only for reporting the current temperature in the frontend.
- **receiver_id** (*Optional*, :ref:`config-id`): The remote_receiver id, see: :ref:`tcl112-receiver_id`.
- All other options from :ref:`Climate <config-climate>`.
Advanced options:
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
- **transmitter_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the remote transmitter.
.. _tcl112-receiver_id:
Using a receiver
----------------
When using a receiver it is recommended to put the IR receiver as close as possible to the equipment's
IR receiver.
.. code-block:: yaml
# Example configuration entry
remote_receiver:
id: rcvr
pin:
number: GPIO14
inverted: True
mode: INPUT_PULLUP
tolerance: 45 # high tolerance required for some remote control units
climate:
- platform: tcl112
name: "Living Room AC"
receiver_id: rcvr
See Also
--------
- :doc:`/components/climate/index`
- :doc:`/components/remote_transmitter`
- :apiref:`tcl112/tcl112.h`
- :ghedit:`Edit`