esphome-docs/components/sensor/pulse_counter.rst
RoboMagus 194c8e429f
Esp32 pulsecounter optional pcnt (#2212)
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
2022-09-02 13:41:09 +12:00

142 lines
4.7 KiB
ReStructuredText
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

Pulse Counter Sensor
====================
.. seo::
:description: Instructions for setting up pulse counter sensors.
:image: pulse.svg
The pulse counter sensor allows you to count the number of pulses and the frequency of a signal
on any pin.
On the ESP32, this sensor is even highly accurate because it's using the hardware `pulse counter
peripheral <https://docs.espressif.com/projects/esp-idf/en/latest/api-reference/peripherals/pcnt.html>`__
on the ESP32. However, due to the use of the pulse counter peripheral, a maximum of 8 channels can be used!
.. figure:: images/pulse-counter.png
:align: center
:width: 80.0%
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: pulse_counter
pin: 12
name: "Pulse Counter"
Configuration variables:
------------------------
- **pin** (**Required**, :ref:`config-pin`): The pin to count pulses on.
- **name** (**Required**, string): The name of the sensor.
- **count_mode** (*Optional*): Configure how the counter should behave
on a detected rising edge/falling edge.
- **rising_edge** (*Optional*): What to do when a rising edge is
detected. One of ``DISABLE``, ``INCREMENT`` and ``DECREMENT``.
Defaults to ``INCREMENT``.
- **falling_edge** (*Optional*): What to do when a falling edge is
detected. One of ``DISABLE``, ``INCREMENT`` and ``DECREMENT``.
Defaults to ``DISABLE``.
- **use_pcnt** (*Optional*, boolean): Use hardware ``PCNT`` pulse counter. Only supported on ESP32. Defaults to ``true``.
- **internal_filter** (*Optional*, :ref:`config-time`): If a pulse shorter than this
time is detected, its discarded and no pulse is counted. Defaults to ``13us``. On the ESP32, when using the hardware pulse counter
this value can not be higher than ``13us``, for the ESP8266 or with ``use_pcnt: false`` you can use larger intervals too.
If you enable this, set up the ``count_mode`` to increase on the falling edge, not leading edge. For S0 pulse meters that are used to meter power consumption 50-100 ms is a reasonable value.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
- **total** (*Optional*): Report the total number of pulses.
- All other options from :ref:`Sensor <config-sensor>`.
.. note::
See :doc:`integration sensor </components/sensor/integration>` for summing up pulse counter
values over time.
Converting units
----------------
The sensor defaults to measuring its values using a unit of measurement
of “pulses/min”. You can change this by using :ref:`sensor-filters`.
For example, if youre using the pulse counter with a photodiode to
count the light pulses on a power meter, you can do the following:
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: pulse_counter
pin: 12
unit_of_measurement: 'kW'
name: 'Power Meter House'
filters:
- multiply: 0.06 # (60s/1000 pulses per kWh)
Counting total pulses
---------------------
When the total sensor is configured, the pulse_counter also reports the total
number of pulses measured. When used on a power meter, this can be used to
measure the total consumed energy in kWh.
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: pulse_counter
pin: 12
unit_of_measurement: 'kW'
name: 'Power Meter House'
filters:
- multiply: 0.06 # (60s/1000 pulses per kWh)
total:
unit_of_measurement: 'kWh'
name: 'Energy Meter House'
filters:
- multiply: 0.001 # (1/1000 pulses per kWh)
(Re)Setting the total pulse count
---------------------------------
Using this action, you are able to reset/set the total pulse count. This can be useful
if you would like the ``total`` sensor to match what you see on your meter you are
trying to match.
.. code-block:: yaml
# Set pulse counter total from home assistant using this service call:
api:
services:
- service: set_pulse_total
variables:
new_pulse_total: int
then:
- pulse_counter.set_total_pulses:
id: pulse_counter_id
value: !lambda 'return new_pulse_total;'
.. note::
This value is the raw count of pulses, and not the value you see after the filters
are applied.
See Also
--------
- :ref:`sensor-filters`
- :doc:`/components/sensor/pulse_meter`
- :doc:`rotary_encoder`
- `esp-idf Pulse Counter API <https://docs.espressif.com/projects/esp-idf/en/latest/api-reference/peripherals/pcnt.html>`__.
- :apiref:`pulse_counter/pulse_counter_sensor.h`
- :ghedit:`Edit`