mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-11-16 10:55:21 +01:00
c305a836f9
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
307 lines
12 KiB
ReStructuredText
307 lines
12 KiB
ReStructuredText
VBus Component
|
|
==============
|
|
|
|
.. seo::
|
|
:description: Instructions for integrating a solar energy collector controller using VBus protocol in ESPHome.
|
|
:image: resol_deltasol_bs_plus.jpg
|
|
:keywords: VBUS RESOL SOLAR
|
|
|
|
The ``VBus`` Component provides status reading connectivity to solar heat energy collector controllers using VBus
|
|
protocol. These devices are mainly produced by Resol, often also found under different brand names like Viessmann,
|
|
Kioto, Wagner etc. The component currently supports natively the models in the table below
|
|
but any device can be added via lambda by knowing `its packet structure <https://danielwippermann.github.io/resol-vbus>`__.
|
|
|
|
.. figure:: ../images/resol_deltasol_bs_plus.jpg
|
|
:align: center
|
|
|
|
Supported Models
|
|
----------------
|
|
|
|
The following table shows the currently supported models of Vbus devices.
|
|
|
|
.. csv-table:: Supported Models
|
|
:header: "Name", "Config Value", "Hex Address", "Notes"
|
|
|
|
"DeltaSol BS Plus","deltasol_bs_plus","4221"
|
|
"DeltaSol BS 2009","deltasol_bs_2009","427B","DeltaSol BS Plus V2"
|
|
"Dux H3214","deltasol_bs_2009","427B", "Pump 2 unsupported"
|
|
"DeltaSol C","deltasol_c","4212"
|
|
"DeltaSol CS2","deltasol_cs2","1121"
|
|
"DeltaSol CS2 Plus","deltasol_cs2_plus","2211"
|
|
|
|
The ``Config Value`` should be used for the ``model`` parameter in your ``sensor`` and ``binary_sensor`` entries.
|
|
|
|
The ``Hex Address`` field is the value sent by a device in the ``from`` field of a message. To identify an unknown
|
|
model, set the logger level to ``VERBOSE`` and look for lines like this in the log output:
|
|
|
|
``[10:53:48][V][vbus:068]: P1 C0500 427b->0000: 0000 0000 (0)``
|
|
|
|
The value before the ``->`` symbol is the device source address. If it matches one of the entries in the table above
|
|
then that model should work with your unit.
|
|
|
|
|
|
Hardware Connection
|
|
-------------------
|
|
|
|
The device must be connected via a :doc:`UART bus </components/uart>` supporting the receiving line only. The UART bus
|
|
must be configured at the same speed of the module which is by default 9600bps. The controller outputs data every second.
|
|
|
|
To connect to this and read data from the bus a level shifting is needed as the voltage is around 8V (direct connection
|
|
would damage the MCU). For our read-only purposes it's
|
|
sufficient to adapt the level appropriately to 3.3V using a circuit like below:
|
|
|
|
.. figure:: ../images/resol_vbus_adapter_schematic.png
|
|
:align: center
|
|
|
|
An electrically isolated version using an opto-coupler:
|
|
|
|
.. figure:: images/vbus_serial_optocoupler.png
|
|
:align: center
|
|
|
|
Another approach, with PCB design ready to be manufactured `can be found here <https://github.com/FatBeard/vbus-arduino-library/tree/master/pcb>`__.
|
|
|
|
.. warning::
|
|
|
|
Do not connect the GND pin of your module with the ground of Resol unit as that may damage the output port of it.
|
|
The output of the device is symmetric, meaning that the signal is not referenced to the ground, but rather it's a
|
|
differential signal between the two wires. However, the MCU references the signal against the ground, so the two
|
|
grounds are not supposed to be connected to each other as can be seen in the circuit depicted above.
|
|
|
|
|
|
Component
|
|
---------
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
uart:
|
|
id: resol
|
|
rx_pin: GPIO3
|
|
baud_rate: 9600
|
|
|
|
vbus:
|
|
uart_id: resol
|
|
|
|
logger:
|
|
baud_rate: 0 # disable uart logger on ESP8266
|
|
|
|
.. warning::
|
|
|
|
If you are using the :doc:`logger` make sure you are not using the same pins for it or otherwise disable the UART
|
|
logging with the ``baud_rate: 0`` option.
|
|
|
|
Configuration variables:
|
|
|
|
- **uart_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the UART hub used to connect to the device.
|
|
|
|
.. note::
|
|
|
|
Functionality of the sensors depends on the type of the device and the scheme arrangement of the hydraulic
|
|
system it controls. The actual arrangement number set up can be determined from the settings of the device. Please
|
|
check the user manual and assess your arrangement to determine the functionality of each sensor and name them
|
|
accordingly.
|
|
|
|
|
|
Sensor
|
|
------
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: vbus
|
|
model: deltasol_bs_plus
|
|
temperature_1:
|
|
name: Temperature 1
|
|
temperature_2:
|
|
name: Temperature 2
|
|
temperature_3:
|
|
name: Temperature 3
|
|
temperature_4:
|
|
name: Temperature 4
|
|
pump_speed_1:
|
|
name: Pump Speed 1
|
|
pump_speed_2:
|
|
name: Pump Speed 2
|
|
operating_hours_1:
|
|
name: Operating Hours 1
|
|
operating_hours_2:
|
|
name: Operating Hours 2
|
|
heat_quantity:
|
|
name: Heat Quantity
|
|
time:
|
|
name: Device Time
|
|
version:
|
|
name: Device firmware version
|
|
|
|
|
|
Configuration variables:
|
|
|
|
- **model** (**Required**): Specify the model of the connected controller. Choose one of the config values listed in the table of supported models above.
|
|
|
|
Supported sensors:
|
|
|
|
- for **deltasol_bs_plus** and **deltasol_bs_2009**: ``temperature_1``, ``temperature_2``, ``temperature_3``, ``temperature_4``, ``pump_speed_1``, ``pump_speed_2``, ``operating_hours_1``, ``operating_hours_2``, ``heat_quantity``, ``time``, ``version``.
|
|
- for **deltasol_c**: ``temperature_1``, ``temperature_2``, ``temperature_3``, ``temperature_4``, ``pump_speed_1``, ``pump_speed_2``, ``operating_hours_1``, ``operating_hours_2``, ``heat_quantity``, ``time``.
|
|
- for **deltasol_cs2**: ``temperature_1``, ``temperature_2``, ``temperature_3``, ``temperature_4``, ``pump_speed``, ``operating_hours``, ``heat_quantity``, ``version``.
|
|
- for **deltasol_cs_plus**: ``temperature_1``, ``temperature_2``, ``temperature_3``, ``temperature_4``, ``temperature_5``, ``pump_speed_1``, ``pump_speed_2``, ``operating_hours_1``, ``operating_hours_2``, ``heat_quantity``, ``time``, ``version``, ``flow_rate``.
|
|
|
|
|
|
All sensors are *Optional* and support all other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
.. note::
|
|
|
|
Sensors are updated every time a data packet is sent by the device. Some models send data very often, possibly every second. If you are
|
|
concerned about the load on the receiving database, you can add a ``throttle`` filter to the sensors.
|
|
|
|
|
|
|
|
Binary Sensor
|
|
-------------
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
binary_sensor:
|
|
- platform: vbus
|
|
model: deltasol_bs_plus
|
|
relay1:
|
|
name: Relay 1 On
|
|
relay2:
|
|
name: Relay 2 On
|
|
sensor1_error:
|
|
name: Sensor 1 Fault
|
|
sensor2_error:
|
|
name: Sensor 2 Fault
|
|
sensor3_error:
|
|
name: Sensor 3 Fault
|
|
sensor4_error:
|
|
name: Sensor 4 Fault
|
|
collector_max:
|
|
name: Option Collector Max
|
|
collector_min:
|
|
name: Option Collector Min
|
|
collector_frost:
|
|
name: Option Collector Frost
|
|
tube_collector:
|
|
name: Option Tube Collector
|
|
recooling:
|
|
name: Option Recooling
|
|
hqm:
|
|
name: Option Heat Quantity Measurement
|
|
|
|
|
|
Configuration variables:
|
|
|
|
- **model** (**Required**): Specify the model of the connected controller. Choose one of the config values listed in the table of supported models above.
|
|
|
|
Supported models:
|
|
|
|
- **``deltasol_bs_plus``**: ``relay1``, ``relay2``, ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``, ``collector_max``, ``collector_min``, ``collector_frost``, ``tube_collector``, ``recooling``, ``hqm``.
|
|
- **``deltasol_bs_2009``**: ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``, ``frost_protection_active``.
|
|
- **``deltasol_c``**: ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``.
|
|
- **``deltasol_cs2``**: ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``.
|
|
- **``deltasol_cs_plus``**: ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``.
|
|
- **``custom``**: See below.
|
|
|
|
All binary sensors are *Optional* and support all other options from :ref:`Binary Sensor <config-binary_sensor>`.
|
|
|
|
|
|
``custom`` VBus sensors
|
|
-----------------------
|
|
|
|
Devices on a VBus are identified with a source address. There can be multiple devices on the same bus,
|
|
each device type has a different address.
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
- platform: vbus
|
|
model: custom
|
|
dest: 0x10
|
|
source: 0x1234
|
|
command: 0x100
|
|
sensors:
|
|
- id: temp1
|
|
name: Temp 1
|
|
lambda: return ((x[1] << 8) + x[0]) / 10.0;
|
|
|
|
|
|
Configuration variables:
|
|
|
|
- **dest** (**Required**): The ``DFA`` value corresponding to your device (see below).
|
|
- **source** (**Required**): The address corresponding to ``your device model`` (see below).
|
|
- **command** (**Required**): The ``command`` corresponding to your device (see below).
|
|
- **sensors** (**Required**): A list of :ref:`Sensor <config-sensor>` definitions that include a ``lambda`` to do the decoding and return a ``float`` value.
|
|
|
|
- **lambda** (**Required**, :ref:`lambda <config-lambda>`): Code to parse a value from the incoming data packets and return it.
|
|
The data packet is in a ``std::vector<uint8_t>`` called ``x``.
|
|
|
|
|
|
``custom`` VBus binary sensors
|
|
------------------------------
|
|
|
|
Configuration variables:
|
|
|
|
- **dest** (**Required**): The ``DFA`` value corresponding to your device (see below).
|
|
- **source** (**Required**): The address corresponding to ``your device model`` (see below).
|
|
- **command** (**Required**): The ``command`` corresponding to your device (see below).
|
|
- **binary_sensors** (**Required**): A list of :ref:`Binary Sensor <config-binary_sensor>` definitions that include a ``lambda`` to do the decoding and return a ``bool`` value.
|
|
|
|
- **lambda** (**Required**, :ref:`lambda <config-lambda>`): Code to parse a value from the incoming data packets and return it.
|
|
The data packet is in a ``std::vector<uint8_t>`` called ``x``.
|
|
|
|
To determine the correct values for the parameters above, visit `packet definitions list <http://danielwippermann.github.io/resol-vbus/#/vsf>`__. In the search field of the **Packets** table, enter the name of your device.
|
|
|
|
To extract the values with a :ref:`lambda <config-lambda>`, look in the packet structure by clicking the **Bytes** link in the table. Each value is placed at an ``offset`` within the packet.
|
|
For ``float`` values, let's look at the temperature example: the value is stored as a ``16``-bit value in ``2`` bytes little-endian format. Since it's always the second byte containing the upper byte, it needs to be shifted by ``8`` bits (multiplied by ``256``) (e.g. ``0x34, 0x12 -> 0x1234``). The result needs to be multiplied by the factor, which is ``0.1``, to obtain the correct values: ``((x[1] << 8) + x[0]) * 0.1f)``. The number within the square brackets is the ``[offset]``.
|
|
For ``binary`` values, multiple binary values are stored within a single numeric value encoded with a bitmask. To extract the binary value all you have to do is to apply *bitwise AND* operator ``&`` between the value at the corresponding offset and the ``mask`` shown in the table.
|
|
|
|
For example to decode some sensors of `DeltaSol BS Plus` via lambdas:
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: vbus
|
|
model: custom
|
|
dest: 0x10
|
|
source: 0x4221
|
|
command: 0x100
|
|
sensors:
|
|
- id: scheme
|
|
name: Arrangement scheme
|
|
icon: mdi:pipe-wrench
|
|
accuracy_decimals: 0
|
|
entity_category: diagnostic
|
|
lambda: return x[14]; // Configured arrangement scheme
|
|
- id: temp2
|
|
name: Temperature DHW
|
|
state_class: measurement
|
|
unit_of_measurement: "°C"
|
|
lambda: return ((x[3] << 8) + x[2]) * 0.1f; // Temperature 2
|
|
|
|
binary_sensor:
|
|
- platform: vbus
|
|
model: custom
|
|
dest: 0x10
|
|
source: 0x4221
|
|
command: 0x100
|
|
binary_sensors:
|
|
- name: Heat Quantity Measurement On
|
|
id: bin_hqm
|
|
icon: mdi:counter
|
|
lambda: return x[15] & 0x20; // Option Heat Quantity Measurement enabled
|
|
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :doc:`/components/uart`
|
|
- :doc:`/components/binary_sensor/index`
|
|
- :doc:`/components/sensor/index`
|
|
- `Resol manuals <https://www.resol.de/en/dokumente>`__
|
|
- `VBus protocol <https://danielwippermann.github.io/resol-vbus>`__
|
|
- :ghedit:`Edit`
|