SHT3X-D Temperature+Humidity Sensor
===================================
.. seo::
:description: Instructions for setting up SHT31-D/SHT3x and SHT85 temperature and humidity sensors
:image: sht3xd.jpg
The ``sht3xd`` sensor platform Temperature+Humidity sensor allows you to use your Sensirion SHT31-D/SHT3x
(`datasheet <https://cdn-shop.adafruit.com/product-files/2857/Sensirion_Humidity_SHT3x_Datasheet_digital-767294.pdf>`__,
`Adafruit`_ ) and SHT85 (`datasheet <https://sensirion.com/media/documents/4B40CEF3/640B2346/Sensirion_Humidity_Sensors_SHT85_Datasheet.pdf>`__,
`Sensirion`_ ) sensors with Esphome.
The :ref:`I²C Bus <i2c>` is required to be set up in your configuration for this sensor to work.
.. _Adafruit: https://www.adafruit.com/product/2857
.. _Sensirion: https://sensirion.com/products/catalog/SHT85/
.. figure:: images/temperature-humidity.png
:align: center
:width: 80.0%
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: sht3xd
temperature:
name: "Living Room Temperature"
humidity:
name: "Living Room Humidity"
address: 0x44
update_interval: 60s
Configuration variables:
------------------------
- **temperature** (*Optional*): The information for the temperature sensor.
- All options from :ref:`Sensor <config-sensor>`.
- **humidity** (*Optional*): The information for the humidity sensor.
- All options from :ref:`Sensor <config-sensor>`.
- **address** (*Optional*, int): Manually specify the I²C address of the sensor.
Defaults to ``0x44``. For SHT3x, an alternate address can be ``0x45`` while SHT85 supports only address ``0x44``
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
sensor. Defaults to ``60s``.
- **heater_enabled** (*Optional*, bool): Turn on/off heater at boot.
This may help provide `more accurate readings in condensing conditions <https://forum.arduino.cc/t/atmospheric-sensors-in-condensing-conditions/412167>`_,
but can also increase temperature readings and decrease humidity readings as a side effect.
Defaults to ``false``.
I²C Configuration when using Higher I²C Frequencies
---------------------------------------------------
When using the **IDF framework** and **I²C frequencies greater than 50-100kHz**, the I²C configuration needs to include a **timeout** option.
On an ESP32, the Arduino framework has a default I²C timeout of 50ms whereas on IDF framework, the default timeout is 100us.
At these higher I²C frequencies, the default I²C timeout on IDF framework causes a "Communication with SHT3xD failed" error on setup.
A solution that has been tested on ESP32 at 800kHz, is to increase the I²C timeout to 10ms as per the following example.
.. code-block:: yaml
# Example I²C configuration
i2c:
sda: 21
scl: 22
scan: true
frequency: 800khz
timeout: 10ms