mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-11-05 09:20:08 +01:00
2f87918189
Document link was not resolving to PDF. Changed link to page listing various documents.
344 lines
15 KiB
ReStructuredText
344 lines
15 KiB
ReStructuredText
PipSolar PV Inverter
|
|
====================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up PipSolar Compatible PV Inverter in ESPHome.
|
|
:image: pipsolar.jpg
|
|
|
|
The PipSolar component allows you to integrate PIP-compatible Inverters in ESPHome.
|
|
It uses :ref:`UART <uart>` for communication.
|
|
|
|
Once configured, you can use sensors, binary sensors, switches and outputs as described below for your projects.
|
|
|
|
.. warning::
|
|
|
|
All functionality is working fine on esp8266 and esp32 chips.
|
|
If you configure a lot of the possible sensors etc. from below it could be that you run out of memory (on esp8266).
|
|
If you configure more than one if this devices with nearly all sensors etc. you run in a stack-size issue. In this case you have to increase stack size.
|
|
|
|
.. figure:: images/pipsolar.jpg
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
pip4048 compatible PV Inverter.
|
|
|
|
Overview
|
|
--------
|
|
|
|
You can connect a wide variety of PV Inverters as long as they provide a serial interface and talk the commands used (at least those you want to use).
|
|
A documentation about the communication protocol mostly supported can be found |here|_.
|
|
|
|
This component will poll the needed polling commands in a loop. If there is a command to send for controlling the inverter this command will be queued and fired as next after the current polling command ends.
|
|
There is a buffer to buffer up to 10 commands.
|
|
|
|
.. |here| replace:: ``here``
|
|
.. _here: https://github.com/jblance/mpp-solar/tree/master/docs
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
uart:
|
|
- id: uart_bus
|
|
tx_pin: GPIO18
|
|
rx_pin: GPIO19
|
|
# most devices use 2400 as baud_rate
|
|
baud_rate: 2400
|
|
|
|
pipsolar:
|
|
- uart_id: uart_bus
|
|
id: inverter0
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- **id** (**Required**, :ref:`config-id`): The id to use for this pipsolar component.
|
|
- **uart_id** (*Optional*): The uart Bus ID
|
|
|
|
Sensors
|
|
-------
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: pipsolar
|
|
pipsolar_id: inverter0
|
|
grid_rating_voltage:
|
|
id: inverter0_grid_rating_voltage
|
|
name: inverter0_grid_rating_voltage
|
|
grid_rating_current:
|
|
id: inverter0_grid_rating_current
|
|
name: inverter0_grid_rating_current
|
|
ac_output_apparent_power:
|
|
id: inverter0_ac_output_apparent_power
|
|
name: inverter0_ac_output_apparent_power
|
|
ac_output_active_power:
|
|
id: inverter0_ac_output_active_power
|
|
name: inverter0_ac_output_active_power
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
All sensors are normal sensors... so all sensor variables are working to.
|
|
|
|
- **grid_rating_voltage** (*Optional*): grid rating voltage
|
|
- **grid_rating_current** (*Optional*): grid rating current
|
|
- **ac_output_rating_voltage** (*Optional*): AC output rating voltage
|
|
- **ac_output_rating_frequency** (*Optional*): AC output rating frequency
|
|
- **ac_output_rating_current** (*Optional*): AC output rating current
|
|
- **ac_output_rating_apparent_power** (*Optional*): AC output rating apparent power
|
|
- **ac_output_rating_active_power** (*Optional*): AC output rating active power
|
|
- **battery_rating_voltage** (*Optional*): battery rating voltage
|
|
- **battery_recharge_voltage** (*Optional*): battery recharge voltage
|
|
- **battery_under_voltage** (*Optional*): battery under voltage
|
|
- **battery_bulk_voltage** (*Optional*): battery bulk voltage
|
|
- **battery_float_voltage** (*Optional*): battery float voltage
|
|
- **battery_type** (*Optional*): battery type
|
|
- **current_max_ac_charging_current** (*Optional*): current max ac charging current
|
|
- **current_max_charging_current** (*Optional*): current max charging current
|
|
- **input_voltage_range** (*Optional*): input voltage range
|
|
- **output_source_priority** (*Optional*): output source priority
|
|
- **charger_source_priority** (*Optional*): charger source priority
|
|
- **parallel_max_num** (*Optional*): parallel max num
|
|
- **machine_type** (*Optional*): machine type
|
|
- **topology** (*Optional*): topology
|
|
- **output_mode** (*Optional*): output mode
|
|
- **battery_redischarge_voltage** (*Optional*): battery re-discharge voltage
|
|
- **pv_ok_condition_for_parallel** (*Optional*): PV OK condition for parallel
|
|
- **pv_power_balance** (*Optional*): PV power balance mode
|
|
|
|
- **grid_voltage** (*Optional*): grid voltage
|
|
- **grid_frequency** (*Optional*): grid frequency
|
|
- **ac_output_voltage** (*Optional*): ac output voltage
|
|
- **ac_output_frequency** (*Optional*): ac output frequency
|
|
- **ac_output_apparent_power** (*Optional*): ac output apparent power
|
|
- **ac_output_active_power** (*Optional*): ac output active power
|
|
- **output_load_percent** (*Optional*): output load percentage
|
|
- **bus_voltage** (*Optional*): bus voltage
|
|
- **battery_voltage** (*Optional*): battery voltage
|
|
- **battery_charging_current** (*Optional*): battery charging current
|
|
- **battery_capacity_percent** (*Optional*): battery capacity percent
|
|
- **inverter_heat_sink_temperature** (*Optional*): inverter heatsink temperature
|
|
- **pv_input_current_for_battery** (*Optional*): pv input current for battery
|
|
- **pv_input_voltage** (*Optional*): pv input voltage
|
|
- **battery_voltage_scc** (*Optional*): battery voltage from scc
|
|
- **battery_discharge_current** (*Optional*): battery discharge current
|
|
- **add_sbu_priority_version** (*Optional*): add sbu priority status
|
|
- **configuration_status** (*Optional*): configuration status
|
|
- **scc_firmware_version** (*Optional*): scc firmware version
|
|
- **battery_voltage_offset_for_fans_on** (*Optional*): battery voltage offset for fans on
|
|
- **eeprom_version** (*Optional*): eeprom version
|
|
- **pv_charging_power** (*Optional*): pc charging power
|
|
|
|
Binary Sensors
|
|
--------------
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
binary_sensor:
|
|
- platform: pipsolar
|
|
pipsolar_id: inverter0
|
|
add_sbu_priority_version:
|
|
id: inverter0_add_sbu_priority_version
|
|
name: inverter0_add_sbu_priority_version
|
|
configuration_status:
|
|
id: inverter0_configuration_status
|
|
name: inverter0_configuration_status
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
All sensors are normal binary sensors... so all binary sensor variables are working to.
|
|
|
|
- **add_sbu_priority_version** (*Optional*): add sbu priority version
|
|
- **configuration_status** (*Optional*): configuration status
|
|
- **scc_firmware_version** (*Optional*): scc firmware version
|
|
- **load_status** (*Optional*): load status
|
|
- **battery_voltage_to_steady_while_charging** (*Optional*): battery voltage to steady while charging
|
|
- **charging_status** (*Optional*): charging status
|
|
- **scc_charging_status** (*Optional*): scc charging status
|
|
- **ac_charging_status** (*Optional*): ac charging status
|
|
- **charging_to_floating_mode** (*Optional*): charging to floating mode
|
|
- **switch_on** (*Optional*): switch on
|
|
- **dustproof_installed** (*Optional*): dustproof installed
|
|
- **silence_buzzer_open_buzzer** (*Optional*): silence buzzer open buzzer
|
|
- **overload_bypass_function** (*Optional*): overload bypass function
|
|
- **lcd_escape_to_default** (*Optional*): lcd escape to default
|
|
- **overload_restart_function** (*Optional*): overload restart function
|
|
- **over_temperature_restart_function** (*Optional*): over temperature restart function
|
|
- **backlight_on** (*Optional*): backlight on
|
|
- **alarm_on_when_primary_source_interrupt** (*Optional*): alarm on when primary source interrupt
|
|
- **fault_code_record** (*Optional*): fault code record
|
|
- **power_saving** (*Optional*): power saving
|
|
|
|
- **warnings_present** (*Optional*): warnings present
|
|
- **faults_present** (*Optional*): faults present
|
|
- **warning_power_loss** (*Optional*): warning power loss
|
|
- **fault_inverter_fault** (*Optional*): fault inverter fault
|
|
- **fault_bus_over** (*Optional*): fault bus over
|
|
- **fault_bus_under** (*Optional*): fault bus under
|
|
- **fault_bus_soft_fail** (*Optional*): fault bus soft fail
|
|
- **warning_line_fail** (*Optional*): warning line fail
|
|
- **fault_opvshort** (*Optional*): fault opvshort
|
|
- **fault_inverter_voltage_too_low** (*Optional*): fault inverter voltage too low
|
|
- **fault_inverter_voltage_too_high** (*Optional*): fault inverter voltage too high
|
|
- **warning_over_temperature** (*Optional*): warning over temperature
|
|
- **warning_fan_lock** (*Optional*): warning fan lock
|
|
- **warning_battery_voltage_high** (*Optional*): warning battery voltage high
|
|
- **warning_battery_low_alarm** (*Optional*): warning battery low alarm
|
|
- **warning_battery_under_shutdown** (*Optional*): warning battery under shutdown
|
|
- **warning_battery_derating** (*Optional*): warning battery derating
|
|
- **warning_over_load** (*Optional*): warning over load
|
|
- **warning_eeprom_failed** (*Optional*): warning eeprom failed
|
|
- **fault_inverter_over_current** (*Optional*): fault inverter over current
|
|
- **fault_inverter_soft_failed** (*Optional*): fault inverter soft failed
|
|
- **fault_self_test_failed** (*Optional*): fault_self_test_failed
|
|
- **fault_op_dc_voltage_over** (*Optional*): fault op dc voltage over
|
|
- **fault_battery_open** (*Optional*): fault battery open
|
|
- **fault_current_sensor_failed** (*Optional*): fault current sensor failed
|
|
- **fault_battery_short** (*Optional*): fault battery short
|
|
- **warning_power_limit** (*Optional*): warning power limit
|
|
- **warning_pv_voltage_high** (*Optional*): warning pv voltage high
|
|
- **fault_mppt_overload** (*Optional*): fault mppt overload
|
|
- **warning_mppt_overload** (*Optional*): warning mppt overload
|
|
- **warning_battery_too_low_to_charge** (*Optional*): warning battery too low to charge
|
|
- **fault_dc_dc_over_current** (*Optional*): fault dc dc over current
|
|
- **fault_code** (*Optional*): fault code
|
|
- **warnung_low_pv_energy** (*Optional*): warnung low pv energy
|
|
- **warning_high_ac_input_during_bus_soft_start** (*Optional*): warning high ac input during bus soft start
|
|
- **warning_battery_equalization** (*Optional*): warning battery equalization
|
|
|
|
Text Sensors
|
|
------------
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
text_sensor:
|
|
- platform: pipsolar
|
|
pipsolar_id: inverter0
|
|
device_mode:
|
|
id: inverter0_device_mode
|
|
name: inverter0_device_mode
|
|
last_qpigs:
|
|
id: inverter0_last_qpigs
|
|
name: inverter0_last_qpigs
|
|
last_qpiri:
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
All sensors are normal text sensors... so all text sensor variables are working to.
|
|
|
|
- **device_mode** (*Optional*): device mode response
|
|
- **last_qpigs** (*Optional*): last qpigs reponse
|
|
- **last_qpiri** (*Optional*): last qpiri reponse
|
|
- **last_qmod** (*Optional*): last qmod reponse
|
|
- **last_qflag** (*Optional*): last qflag reponse
|
|
- **last_qpiws** (*Optional*): last qpiws reponse
|
|
- **last_qt** (*Optional*): last qt reponse
|
|
- **last_qmn** (*Optional*): last qmn reponse
|
|
|
|
Switches
|
|
--------
|
|
Not all possible switches are exposed as they lead to the possibility to make serious damage. They should only be set at the physical device itself.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
switch:
|
|
- platform: pipsolar
|
|
pipsolar_id: inverter0
|
|
output_source_priority_utility:
|
|
name: inverter0_output_source_priority_utility
|
|
output_source_priority_solar:
|
|
name: inverter0_output_source_priority_solar
|
|
output_source_priority_battery:
|
|
name: inverter0_output_source_priority_battery
|
|
input_voltage_range:
|
|
name: inverter0_input_voltage_range
|
|
pv_ok_condition_for_parallel:
|
|
name: inverter0_pv_ok_condition_for_parallel
|
|
pv_power_balance:
|
|
name: inverter0_pv_power_balance
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
All sensors are normal text sensors... so all text sensor variables are working to.
|
|
|
|
- **output_source_priority_utility** (*Optional*): output source priority utility
|
|
- **output_source_priority_solar** (*Optional*): output source priority solar
|
|
- **output_source_priority_battery** (*Optional*): output source priority battery
|
|
- **input_voltage_range** (*Optional*): input voltage range
|
|
- **pv_ok_condition_for_parallel** (*Optional*): pv ok condition for parallel
|
|
- **pv_power_balance** (*Optional*): pv power balance
|
|
|
|
Outputs
|
|
--------------
|
|
Not all possible outputs are exposed as they lead to the possibility to make serious damage. They should only be set at the physical device itself.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
output:
|
|
- platform: pipsolar
|
|
pipsolar_id: inverter0
|
|
battery_recharge_voltage:
|
|
id: inverter0_battery_recharge_voltage_out
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
All sensors are normal text sensors... so all text sensor variables are working to.
|
|
|
|
- **battery_recharge_voltage** (*Optional*): battery recharge voltage;
|
|
|
|
- **possible_values** (*Optional*,list): a list of possible values default: 44.0,45.0,46.0,47.0,48.0,49.0,50.0,51.0
|
|
- **battery_under_voltage** (*Optional*): battery under voltage;
|
|
|
|
- **possible_values** (*Optional*,list): a list of possible values default: 40.0,40.1,42,43,44,45,46,47,48.0
|
|
- **battery_float_voltage** (*Optional*): battery float voltage;
|
|
|
|
- **possible_values** (*Optional*,list): a list of possible values default: 48.0,49.0,50.0,51.0
|
|
- **battery_type** (*Optional*): battery type;
|
|
|
|
- **possible_values** (*Optional*,list): a list of possible values default: 0,1,2
|
|
- **current_max_ac_charging_current** (*Optional*): current max ac charging current;
|
|
|
|
- **possible_values** (*Optional*,list): a list of possible values default: 2,10,20
|
|
- **current_max_charging_current** (*Optional*): current max charging current;
|
|
|
|
- **possible_values** (*Optional*,list): a list of possible values default: 10,20,30,40
|
|
- **output_source_priority** (*Optional*): output source priority;
|
|
|
|
- **possible_values** (*Optional*,list): a list of possible values default: 0,1,2
|
|
- **charger_source_priority** (*Optional*): charger source priority;
|
|
|
|
- **possible_values** (*Optional*,list): a list of possible values default: 0,1,2,3
|
|
- **battery_redischarge_voltage** (*Optional*): battery redischarge voltage;
|
|
|
|
- **possible_values** (*Optional*,list): a list of possible values default: 00.0,48.0,49,50.0,51.0,52,53,54,55,56,57,58
|
|
|
|
.. _pipsolaroutput_set_level_action:
|
|
|
|
``output.pipsolar.set_level`` Action
|
|
------------------------------------
|
|
|
|
To use your outputs in :ref:`automations <automation>` or templates, you can use this action to set the
|
|
target level of the output.
|
|
|
|
.. code-block:: yaml
|
|
|
|
on_...:
|
|
then:
|
|
- output.pipsolar.set_level:
|
|
id: my_pipsolar_output
|
|
level: 48.0
|
|
|
|
|
|
Configuration options:
|
|
|
|
- **id** (**Required**, :ref:`config-id`): The ID of the output.
|
|
- **level** (*Optional*, percentage, :ref:`templatable <config-templatable>`): The target level.
|
|
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :ref:`uart`
|
|
- :ghedit:`Edit`
|