For seasonal changes, it’s easier to use the multiplier to adjust the watering time instead of adjusting the run durations directly. Set your run duration to the time you want for ‘mild’ weather (spring/autumn) and then use the multiplier to increase (summer) or decrease (winter) the calculated run times.
1293 lines
60 KiB
ReStructuredText
1293 lines
60 KiB
ReStructuredText
Sprinkler Controller
|
||
====================
|
||
|
||
.. seo::
|
||
:description: Instructions for setting up the sprinkler controller component in ESPHome to control sprinkler valves.
|
||
:image: sprinkler-variant.svg
|
||
|
||
.. figure:: images/sprinkler.png
|
||
:align: center
|
||
|
||
The ``sprinkler`` controller component aims to behave like a sprinkler/irrigation valve controller,
|
||
much like those made by companies such as Rain Bird or Hunter. It does so by automating control of a
|
||
number of :ref:`switch <config-switch>` components, each of which would typically be used to control
|
||
an individual electric valve via a relay or other switching device. It provides a number of features
|
||
you'd expect of a sprinkler controller, including:
|
||
|
||
- Virtually any number of zones (sections of the sprinkler system) per controller instance, limited only by
|
||
available memory and/or GPIO (including I/O expanders!) pin availability on the ESP
|
||
- The ability to run:
|
||
|
||
- One or more full cycles (iterations through all zones) of the system
|
||
- Only a single zone
|
||
|
||
- Automatic cycle repeating
|
||
- A multiplier value to proportionally increase or decrease the run duration for all zones
|
||
- Support for pumps/main valves located upstream of distribution valves
|
||
- Pausing and resuming a zone/cycle
|
||
- Iterating through zones in forward or reverse order
|
||
- Support for both latching ("pulsed") and non-latching valves (which can be arbitrarily mixed!)
|
||
|
||
It reaches even further, however, offering several more advanced features, as well:
|
||
|
||
- Multiple sprinkler controller instances can operate simultaneously on a single (ESP) device
|
||
- Multiple pumps, each of which may be shared across controller instances
|
||
- Enable/disable switches for each individual zone, allowing zones to be omitted from full cycles of the system
|
||
- A valve/zone queuing mechanism aimed at providing advanced support for automation
|
||
- Several valve management strategies to accommodate varying types of hardware/installations:
|
||
|
||
- Adjustable "valve open delay" to help ensure valves are fully closed before the next one is opened
|
||
- Adjustable "valve overlap" to help minimize banging of pipes due to water hammer
|
||
- Adjustable delay intervals to coordinate pump starting and stopping relative to distribution valve opening and closing
|
||
|
||
.. note::
|
||
|
||
While the term "pump" is used throughout this document, the device controlled need not be a
|
||
physical pump. Instead, it may simply be another electric valve located upstream of distribution
|
||
valves (often known in the industry as a "main" or "master" valve). The pump or upstream valve
|
||
simply controls the water supply to other downstream valves.
|
||
|
||
.. figure:: images/sprinkler-ui.jpg
|
||
:align: center
|
||
:width: 60.0%
|
||
|
||
Example Sprinkler Controller UI -- Note that this example leverages :doc:`number </components/number/index>`
|
||
components for setting run durations, repeat and multiplier values.
|
||
:ref:`More details below. <sprinkler-controller-sprinkler_controller_numbers>`
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Example minimal configuration entry
|
||
# (...but please see more detailed examples below!)
|
||
sprinkler:
|
||
- id: sprinkler_ctrlr
|
||
main_switch: "Sprinklers"
|
||
auto_advance_switch: "Sprinklers Auto Advance"
|
||
valves:
|
||
- valve_switch: "Front Lawn"
|
||
enable_switch: "Enable Front Lawn"
|
||
run_duration: 1800s
|
||
valve_switch_id: lawn_sprinkler_valve_sw0
|
||
- valve_switch: "Back Lawn"
|
||
enable_switch: "Enable Back Lawn"
|
||
run_duration: 900s
|
||
valve_switch_id: lawn_sprinkler_valve_sw1
|
||
|
||
Please see the :ref:`sprinkler-controller-examples` section below for extensive, detailed configuration
|
||
examples that are ready for you to copy and paste!
|
||
|
||
Configuration variables:
|
||
------------------------
|
||
|
||
- **main_switch** (*Optional*, *string*): Required with more than one valve. The name for the sprinkler
|
||
controller's main switch as it will appear in the front end. This switch, when turned on, calls the
|
||
``sprinkler.resume_or_start_full_cycle`` action; when turned off, it calls the ``sprinkler.shutdown``
|
||
action (see below). It will appear to be "on" when any valve on the controller is active. This switch
|
||
will not appear in the front end if the controller is configured with only one valve.
|
||
- **auto_advance_switch** (*Optional*, *string*): Required with more than one valve. The name for the
|
||
sprinkler controller's "auto-advance" switch as it will appear in the front end. When this switch is
|
||
turned on while a valve is active, when the valve's ``run_duration`` is reached, the sprinkler
|
||
controller will automatically advance to the next enabled valve as a part of a "full cycle" of the
|
||
system. When turned off, the sprinkler controller will shut down after the active valve's
|
||
``run_duration`` is reached (unless there are valves in the queue -- see
|
||
:ref:`sprinkler-controller-sprinkler_controller_queue` section below for more detail). This switch will
|
||
not appear in the front end if the controller is configured with only one valve.
|
||
- **manual_selection_delay** (*Optional*, :ref:`config-time`): The amount of time the controller should
|
||
wait to activate a valve after the ``next_valve`` and ``previous_valve`` actions are called. Useful
|
||
if the control interface consists of only forward/reverse buttons as the button(s) may be pressed
|
||
multiple times to make the selection.
|
||
- **queue_enable_switch** (*Optional*, *string*): The name for the sprinkler controller's queue enable
|
||
switch as it will appear in the front end. When this switch is turned on or not provided, the controller
|
||
will select the next valve/zone to run based on the contents of the queue; the queue takes precedence over
|
||
valves that would otherwise run as a part of a full cycle of the system (when auto-advance is on/enabled).
|
||
See :ref:`sprinkler-controller-sprinkler_controller_queue` section below for more detail.
|
||
- **reverse_switch** (*Optional*, *string*): The name for the sprinkler controller's reverse switch
|
||
as it will appear in the front end. When this switch is turned on, the controller will iterate through
|
||
the valves in reverse order (last-to-first as they appear in the controller's configuration). When
|
||
this switch is turned off or not provided, the controller will iterate through the valves first-to-last.
|
||
This switch will not appear in the front end if the controller is configured with only one valve.
|
||
- **standby_switch** (*Optional*, *string*): The name for the sprinkler controller's standby switch
|
||
as it will appear in the front end. When this switch is turned on, the controller *will not start any valves.*
|
||
**This can result in confusing/unexpected behavior if there is no visual indication of this condition!**
|
||
- **valve_open_delay** (*Optional*, :ref:`config-time`): The *minimum* delay in seconds that should be
|
||
inserted between (distribution) valve switching -- in other words, the amount of time that must elapse
|
||
between one valve switching off and the next one switching on. Useful for systems with valves which depend
|
||
on sufficient water pressure to close. May not be used with ``valve_overlap``.
|
||
- **valve_overlap** (*Optional*, :ref:`config-time`): The amount of time in seconds that the current valve
|
||
and the next valve should run simultaneously as the next valve/zone starts up. This may help prevent pipes
|
||
from banging as valves close. May not be used with ``valve_open_delay``.
|
||
- **pump_switch_off_during_valve_open_delay** (*Optional*, boolean): If set to ``true``, the pump will be
|
||
switched off during the ``valve_open_delay`` interval; otherwise, it remains on. This may only be
|
||
specified when ``valve_open_delay`` is configured (see above). Defaults to ``false``.
|
||
- **pump_start_pump_delay** (*Optional*, :ref:`config-time`): The delay in seconds from when a distribution
|
||
valve is opened to when the associated pump is activated. Useful to ensure pressure does not build
|
||
up from running the pump when no distribution valves are open. May not be used with ``pump_start_valve_delay``.
|
||
- **pump_start_valve_delay** (*Optional*, :ref:`config-time`): The delay in seconds from when a pump
|
||
is started to when the associated distribution valve is opened. Useful for systems where distribution
|
||
valves require sufficient pressure to fully/quickly close. May not be used with ``pump_start_pump_delay``.
|
||
- **pump_stop_pump_delay** (*Optional*, :ref:`config-time`): The delay in seconds from when a distribution
|
||
valve is closed to when the respective pump is deactivated. Useful for systems where distribution valves
|
||
require sufficient pressure to fully/quickly close. May not be used with ``pump_stop_valve_delay``.
|
||
- **pump_stop_valve_delay** (*Optional*, :ref:`config-time`): The delay in seconds from when a pump is
|
||
deactivated to when the respective distribution valve is closed. Useful to ensure pressure does not build
|
||
up from running the pump when no distribution valves are open or to allow the main line out to distribution
|
||
valves to drain. May not be used with ``pump_stop_pump_delay``.
|
||
- **pump_pulse_duration** (*Optional*, :ref:`config-time`): The *minimum* length of the pulse generated to
|
||
operate a pump in milliseconds. *Required* when one or more latching pumps is configured. Note that the *exact*
|
||
length of the pulse is determined by the frequency of the main application loop (as are other ``delay`` timers
|
||
used in ESPHome). Typically this is expected to provide a resolution of approximately 16 milliseconds, however
|
||
this may vary somewhat depending on your exact configuration. Regardless, it should provide
|
||
more-than-sufficient precision to operate any such valve.
|
||
- **valve_pulse_duration** (*Optional*, :ref:`config-time`): The *minimum* length of the pulse generated to
|
||
operate a valve in milliseconds. *Required* when one or more latching valves is configured. Note that the *exact*
|
||
length of the pulse is determined by the frequency of the main application loop (as are other ``delay`` timers
|
||
used in ESPHome). Typically this is expected to provide a resolution of approximately 16 milliseconds, however
|
||
this may vary somewhat depending on your exact configuration. Regardless, it should provide more-than-sufficient
|
||
precision to operate any such valve.
|
||
- **multiplier_number** (*Optional*, *string*): The name of the :doc:`number </components/number/index>` component that
|
||
should be presented to the front end (Home Assistant) to enable control of the sprinkler controller's ``multiplier``
|
||
value. See :ref:`sprinkler-controller-sprinkler_controller_numbers` below for more detail.
|
||
- **repeat_number** (*Optional*, *string*): The name of the :doc:`number </components/number/index>` component that
|
||
should be presented to the front end (Home Assistant) to enable control of the sprinkler controller's ``repeat``
|
||
value. May not be used with ``repeat``. See :ref:`sprinkler-controller-sprinkler_controller_numbers` below for more
|
||
detail.
|
||
- **repeat** (*Optional*, int): The number of times a full cycle should be repeated. Defaults to 0. May not be used
|
||
with ``repeat_number``.
|
||
- **next_prev_ignore_disabled** (*Optional*, boolean): Set to ``true`` to cause
|
||
:ref:`sprinkler-controller-action_next_valve` and :ref:`sprinkler-controller-action_previous_valve` to skip
|
||
over valves that are not enabled. Defaults to ``false``.
|
||
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation. While optional,
|
||
this is necessary to identify the controller instance (particularly in cases where more than one is
|
||
defined) when calling controller actions (see below) such as ``start_full_cycle`` or ``shutdown``.
|
||
- **valves** (**Required**, *list*): A list of valves the controller should use. Each valve consists of:
|
||
|
||
- **enable_switch** (*Optional*, *string*): The name for the switch component to be used to enable
|
||
this valve to be run as a part of a full cycle of the system. When this switch is turned off, the valve
|
||
will be excluded from a full cycle of the system. When this switch is turned on or not provided, the
|
||
controller will include the valve in a full cycle of the system.
|
||
- **valve_switch** (**Required**, *string*): The name for the switch component to be used to control
|
||
the valve for this part of the sprinkler system (often referred to as a "zone"). When this switch is
|
||
turned on, the controller's "auto-advance" feature is disabled and it will activate the associated
|
||
valve for its ``run_duration`` multiplied by the controller's multiplier value. When this switch is
|
||
turned off, the ``sprinkler.shutdown`` action is called (see below).
|
||
- **pump_switch_id** (*Optional*, :ref:`Switch <config-switch>`): This is the :ref:`switch <config-switch>`
|
||
component to be used to control the valve's pump or upstream electric valve. Typically this would be a
|
||
:doc:`GPIO switch <switch/gpio>` wired to control a relay or other switching device which in turn would
|
||
activate the respective pump/valve. *It is not recommended to expose this switch to the front end; please
|
||
see* :ref:`sprinkler-controller-an_important_note_about_gpio_switches_and_control` *below for more detail.*
|
||
May not be specified with *pump_off_switch_id* or *pump_on_switch_id*.
|
||
- **pump_off_switch_id** (*Optional*, :ref:`Switch <config-switch>`): This is the :ref:`switch <config-switch>`
|
||
component to be used to *turn off* the valve's pump or upstream electric *latching* valve. Typically this
|
||
would be a :doc:`GPIO switch <switch/gpio>` wired to control a relay or other switching device which in turn
|
||
would *switch off* the respective pump/valve. *It is not recommended to expose this switch to the front end; please
|
||
see* :ref:`sprinkler-controller-an_important_note_about_gpio_switches_and_control` *below for more detail.*
|
||
May not be specified with *pump_switch_id*.
|
||
- **pump_on_switch_id** (*Optional*, :ref:`Switch <config-switch>`): This is the :ref:`switch <config-switch>`
|
||
component to be used to *turn on* the valve's pump or upstream electric *latching* valve. Typically this
|
||
would be a :doc:`GPIO switch <switch/gpio>` wired to control a relay or other switching device which in turn
|
||
would *switch on* the respective pump/valve. *It is not recommended to expose this switch to the front end; please
|
||
see* :ref:`sprinkler-controller-an_important_note_about_gpio_switches_and_control` *below for more detail.*
|
||
May not be specified with *pump_switch_id*.
|
||
- **run_duration_number** (*Optional*, *string*): The name of the :doc:`number </components/number/index>` component
|
||
that should be presented to the front end (Home Assistant) to enable control of the valve's ``run_duration`` value.
|
||
May not be used with ``run_duration``. See :ref:`sprinkler-controller-sprinkler_controller_numbers` below for more
|
||
detail. **Pro tip:** Want times in minutes? Add ``unit_of_measurement: min`` to the number configuration. See
|
||
:ref:`sprinkler-controller-sprinkler_controller_numbers` for more detail.
|
||
- **run_duration** (*Optional*, :ref:`config-time`): Required when ``run_duration_number`` is not provided. The
|
||
duration in seconds this valve should remain on/open after it is activated. When a given valve is activated, the
|
||
controller's multiplier value is multiplied by this value to determine the actual run duration for the valve, thus
|
||
allowing the run duration for all valves/zones to be proportionally increased or decreased as desired. May not be
|
||
used with ``run_duration_number``.
|
||
- **valve_switch_id** (**Required**, :ref:`Switch <config-switch>`): This is the :ref:`switch <config-switch>`
|
||
component to be used to control the valve that operates the given section or zone of the sprinkler
|
||
system. Typically this would be a :doc:`GPIO switch <switch/gpio>` wired to control a relay
|
||
or other switching device which in turn would activate the respective valve. *It is not recommended
|
||
to expose this switch to the front end; please see* :ref:`sprinkler-controller-an_important_note_about_gpio_switches_and_control`
|
||
*below for more detail.* May not be specified with *valve_off_switch_id* or *valve_on_switch_id*.
|
||
- **valve_off_switch_id** (**Required**, :ref:`Switch <config-switch>`): This is the :ref:`switch <config-switch>`
|
||
component to be used to *turn off* the *latching* valve that operates the given section or zone of the
|
||
sprinkler system. Typically this would be a :doc:`GPIO switch <switch/gpio>` wired to control a relay
|
||
or other switching device which in turn would *switch off* the respective valve. *It is not recommended
|
||
to expose this switch to the front end; please see* :ref:`sprinkler-controller-an_important_note_about_gpio_switches_and_control`
|
||
*below for more detail.* May not be specified with *valve_switch_id*.
|
||
- **valve_on_switch_id** (**Required**, :ref:`Switch <config-switch>`): This is the :ref:`switch <config-switch>`
|
||
component to be used to *turn on* the *latching* valve that operates the given section or zone of the
|
||
sprinkler system. Typically this would be a :doc:`GPIO switch <switch/gpio>` wired to control a relay
|
||
or other switching device which in turn would *switch on* the respective valve. *It is not recommended
|
||
to expose this switch to the front end; please see* :ref:`sprinkler-controller-an_important_note_about_gpio_switches_and_control`
|
||
*below for more detail.* May not be specified with *valve_switch_id*.
|
||
|
||
.. _sprinkler-controller-an_important_note_about_gpio_switches_and_control:
|
||
|
||
An Important Note about GPIO Switches and Control
|
||
-------------------------------------------------
|
||
|
||
The savvy and/or seasoned ESPHome user will quickly realize that ``pump_switch_id``, ``pump_off_switch_id``,
|
||
``pump_on_switch_id``, ``valve_switch_id``, ``valve_off_switch_id`` and ``valve_on_switch_id`` (as described above)
|
||
are really just pointers to other (GPIO) switches elsewhere in the ESPHome yaml configuration.
|
||
|
||
It might seem reasonable to assume that these :doc:`GPIO switches <switch/gpio>` may be used to switch the various
|
||
sprinkler zones on and off, however, this is **not** the case. It's important to note that the sprinkler controller
|
||
provides a switch for each configured zone -- ultimately, this switch is to be used to switch any given zone on or
|
||
off, **not** the :doc:`GPIO switch <switch/gpio>` the zone is configured with.
|
||
|
||
Keep in mind that a :doc:`GPIO switch <switch/gpio>` directly controls the state of the GPIO pin it is associated
|
||
with. While it's technically feasible to "override" this behavior, it might not always be desirable. For example,
|
||
if you *wanted* to control the state of the switch/pin manually during testing of your system/configuration, this
|
||
would make doing so impossible (or at least more difficult than necessary), presenting other complications. Ultimately,
|
||
flexibility is key, as we've learned from any number of conversations on the ESPHome Discord server.
|
||
|
||
As mentioned in the introduction, the sprinkler controller automates control of the :doc:`GPIO switches <switch/gpio>`
|
||
you provide it with -- it does not "override" control of these switches or alter how they behave beyond simply
|
||
switching them on or off as required based on the configured scheduling.
|
||
|
||
So why not just use the :doc:`GPIO switch <switch/gpio>` to control the various sprinkler zones directly? As it relates
|
||
to the sprinkler controller itself, the primary reason relates to *state* -- that is, we need to be able to ensure
|
||
that the :doc:`GPIO switch <switch/gpio>` state(s) are kept consistent with the configuration of the sprinkler
|
||
controller. While it's less important for systems that simply consist of one valve per zone, it becomes very important
|
||
for systems with some additional complexity. Consider the example of a system with a pump and multiple distribution
|
||
valves attached to said pump; the controller in this case is configured to switch the pump off three seconds *before*
|
||
switching off any given distribution valve. If you suddenly manually switch off a :doc:`GPIO switch <switch/gpio>`
|
||
connected to one of these distribution valves, what happens to the pump? What should the sprinkler controller do? Should
|
||
it switch the distribution valve back on?...or maybe just switch the pump off, too? In either case, based on its
|
||
configuration, the pump was supposed be shut down before the valve, but you just went and turned off the valve. The pump
|
||
could be damaged. There are many other similar situations such as this that may occur, the simplest of which is little
|
||
more than ensuring that any given valve is switched off after *some* duration and does not remain on/open perpetually.
|
||
|
||
In summary, to ensure that your sprinkler controller consistently operates as expected:
|
||
|
||
- Only use the switches provided by the sprinkler controller component to switch any given sprinkler zone on or off.
|
||
- Do not use the :doc:`GPIO switches <switch/gpio>` you have in your configuration to control sprinkler zones/valves
|
||
outside of initial testing of your device configuration.
|
||
- To help prevent accidents, it's probably best if the :doc:`GPIO switches <switch/gpio>` for each sprinkler zone are
|
||
**not** exposed to the front end. This can be accomplished in two ways:
|
||
|
||
- Do not provide a ``name:`` parameter to your :doc:`GPIO switches <switch/gpio>`, or
|
||
- Add ``internal: true`` to each of your :doc:`GPIO switch <switch/gpio>` configurations
|
||
|
||
These simple configuration tweaks will help prevent any number of errors (human, automation, or otherwise) and may help
|
||
to avert disaster!
|
||
|
||
.. _sprinkler-controller-actions:
|
||
|
||
Controller Actions
|
||
------------------
|
||
|
||
.. _sprinkler-controller-action_start_full_cycle:
|
||
|
||
``sprinkler.start_full_cycle`` action
|
||
*************************************
|
||
|
||
Starts a full cycle of the system. This enables the controller's "auto-advance" feature and disables
|
||
the queue. The controller will iterate through all enabled valves/zones. They will each run for their
|
||
configured ``run_duration`` multiplied by the controller's multiplier value. *Note that if NO valves
|
||
are enabled when this action is called, the controller will automatically enable all valves.*
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.start_full_cycle: sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-action_start_from_queue:
|
||
|
||
``sprinkler.start_from_queue`` action
|
||
*************************************
|
||
|
||
Starts the controller running valves from its queue. If no valves are in the queue, this action does
|
||
nothing; otherwise, this disables the controller's "auto-advance" feature so that only queued
|
||
valves/zones will run. Queued valves will remain on for either the amount of time specified in the
|
||
queue request or for their configured ``run_duration`` multiplied by the controller's multiplier value
|
||
(if the queue request run duration is not specified or is zero). *Note that queued valves ignore whether
|
||
the valve is enabled; that is, queued valves will always run once the controller is started, unless, of
|
||
course, the queue is (manually) cleared prior to the queue reaching them. Also note that, at present,
|
||
the queue has a hard-coded limit of 100 entries to limit memory use.*
|
||
See :ref:`sprinkler-controller-sprinkler_controller_queue` section below for more detail.
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.start_from_queue:
|
||
id: sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-action_start_single_valve:
|
||
|
||
``sprinkler.start_single_valve`` action
|
||
***************************************
|
||
|
||
Starts a single valve. This disables the controller's "auto-advance" and queue features so that only this valve/zone
|
||
will run. The valve will remain on for the specified duration or (if ``run_duration`` is not specified or is zero) for
|
||
its configured ``run_duration`` multiplied by the controller's multiplier value. *Note that this action ignores whether
|
||
the valve is enabled; that is, when called, the specified valve will always run.* Valves are numbered in the order they
|
||
appear in the sprinkler controller's configuration starting at zero (0).
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.start_single_valve:
|
||
id: sprinkler_ctrlr
|
||
valve_number: 0
|
||
run_duration: 600s # optional
|
||
|
||
.. _sprinkler-controller-action_shutdown:
|
||
|
||
``sprinkler.shutdown`` action
|
||
*****************************
|
||
|
||
Initiates a shutdown of all valves/the system, respecting any configured pump or valve stop delays.
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.shutdown: sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-action_next_valve:
|
||
|
||
``sprinkler.next_valve`` action
|
||
*******************************
|
||
|
||
Advances to the next valve (numerically). If ``manual_selection_delay`` is configured, the controller
|
||
will wait before activating the selected valve. If no valve is active, the first valve (as they appear
|
||
in the controller's configuration) will be started. Setting ``next_prev_ignore_disabled`` to ``true``
|
||
will cause this action to skip valves that are not enabled via their valve enable switch (see above).
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.next_valve: sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-action_previous_valve:
|
||
|
||
``sprinkler.previous_valve`` action
|
||
***********************************
|
||
|
||
Advances to the previous valve (numerically). If ``manual_selection_delay`` is configured, the controller
|
||
will wait before activating the selected valve. If no valve is active, the last valve (as they appear in
|
||
the controller's configuration) will be started. Setting ``next_prev_ignore_disabled`` to ``true`` will
|
||
cause this action to skip valves that are not enabled via their valve enable switch (see above).
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.previous_valve: sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-action_pause:
|
||
|
||
``sprinkler.pause`` action
|
||
**************************
|
||
|
||
Immediately turns off all valves, saving the active valve and the amount of time remaining so that
|
||
the cycle may be resumed later on.
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.pause: sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-action_resume:
|
||
|
||
``sprinkler.resume`` action
|
||
***************************
|
||
|
||
Resumes a cycle placed on hold with ``sprinkler.pause``. If there is no paused cycle, this action
|
||
will do nothing.
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.resume: sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-action_resume_or_start_full_cycle:
|
||
|
||
``sprinkler.resume_or_start_full_cycle`` action
|
||
***********************************************
|
||
|
||
Resumes a cycle placed on hold with ``sprinkler.pause``, but if no cycle was paused, starts a full
|
||
cycle (equivalent to ``sprinkler.start_full_cycle``).
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.resume_or_start_full_cycle: sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-action_queue_valve:
|
||
|
||
``sprinkler.queue_valve`` action
|
||
********************************
|
||
|
||
Adds the specified valve into the controller's queue. When the queue is enabled, valves in the queue
|
||
take precedence over valves scheduled as a part of a full cycle of the system (when auto-advance is
|
||
enabled). If ``run_duration`` is not specified or is zero, the sprinkler controller will use the
|
||
valve's configured run duration. Valves are numbered in the order they appear in the sprinkler
|
||
controller's configuration starting at zero (0). *Note that, at present, the queue has a hard-coded
|
||
limit of 100 entries to limit memory use.* Please see :ref:`sprinkler-controller-sprinkler_controller_queue`
|
||
section below for more detail and examples.
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.queue_valve:
|
||
id: sprinkler_ctrlr
|
||
valve_number: 2
|
||
run_duration: 900s
|
||
|
||
.. _sprinkler-controller-action_clear_queued_valves:
|
||
|
||
``sprinkler.clear_queued_valves`` action
|
||
****************************************
|
||
|
||
Removes all queued valves from the controller's queue. Please see :ref:`sprinkler-controller-sprinkler_controller_queue`
|
||
section below for more detail and examples.
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.clear_queued_valves:
|
||
id: sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-action_set_multiplier:
|
||
|
||
``sprinkler.set_multiplier`` action
|
||
***********************************
|
||
|
||
Sets the multiplier value used to proportionally increase or decrease the run duration for all valves/zones.
|
||
For seasonal changes, it’s easier to use the multiplier to adjust the watering time instead of adjusting the
|
||
run durations directly. Set your run duration to the time you want for ‘mild’ weather (spring/autumn) and then
|
||
use the multiplier to increase (summer) or decrease (winter) the calculated run times. When a given valve is
|
||
activated, this value is multiplied by the valve's run duration (see below) to determine the valve's actual
|
||
run duration. *Note that a multiplier value of zero is allowed; if the multiplier value is zero, the
|
||
sprinkler controller will not start any valves.* **This can result in confusing/unexpected behavior if
|
||
a visual indication of this condition is not available!**
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.set_multiplier:
|
||
id: sprinkler_ctrlr
|
||
multiplier: 1.5
|
||
|
||
.. _sprinkler-controller-action_set_repeat:
|
||
|
||
``sprinkler.set_repeat`` action
|
||
*******************************
|
||
|
||
Specifies the number of times full cycles should be repeated. **Note that the total number of cycles
|
||
the controller will run is equal to the repeat value plus one.** For example, with a ``repeat`` value
|
||
of 1, the initial cycle will run, then the repeat cycle will run, resulting in a total of two cycles.
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.set_repeat:
|
||
id: sprinkler_ctrlr
|
||
repeat: 2 # would run three cycles
|
||
|
||
.. _sprinkler-controller-action_set_divider:
|
||
|
||
``sprinkler.set_divider`` action
|
||
********************************
|
||
|
||
The divider value sets both the multiplier and repeat values as follows:
|
||
|
||
- The multiplier value is set to the value of 1 / ``divider``
|
||
- The repeat value is set to ``divider`` - 1
|
||
|
||
As an example, given a divider value of 4, the multiplier would be set to 0.25 and the repeat value
|
||
would be set to 3.
|
||
|
||
This can be useful for dividing the run duration for each valve into multiple shorter cycles, therefore
|
||
avoiding run-off by allowing the ground more time to absorb the water.
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.set_divider:
|
||
id: sprinkler_ctrlr
|
||
divider: 2
|
||
|
||
.. _sprinkler-controller-action_set_valve_run_duration:
|
||
|
||
``sprinkler.set_valve_run_duration`` action
|
||
*******************************************
|
||
|
||
Sets the run duration for the specified valve. When the valve is activated, this value is multiplied
|
||
by the multiplier value (see above) to determine the valve's actual run duration.
|
||
|
||
.. code-block:: yaml
|
||
|
||
on_...:
|
||
then:
|
||
- sprinkler.set_valve_run_duration:
|
||
id: sprinkler_ctrlr
|
||
valve_number: 0
|
||
run_duration: 600s
|
||
|
||
.. note::
|
||
|
||
- The ``start_single_valve`` action ignores whether a valve is enabled via its enable switch.
|
||
- The ``next_valve`` and ``previous_valve`` actions may not appear to respond immediately if either
|
||
``manual_selection_delay`` or any of the various delay mechanisms described in the
|
||
:ref:`sprinkler-controller-pump_and_distribution_valve_coordination` section below are configured.
|
||
If you are using any of these configuration options, be sure to allow the delay intervals to elapse
|
||
before assuming something isn't working!
|
||
- If a valve is active when its ``run_duration`` or the multiplier value is changed, the active
|
||
valve's run duration will remain unaffected until the next time it is started.
|
||
|
||
.. _sprinkler-controller-pump_and_distribution_valve_coordination:
|
||
|
||
Pump and Distribution Valve Coordination
|
||
----------------------------------------
|
||
|
||
The sprinkler controller allows extensive flexibility relating to the switching of pumps and valves.
|
||
Let's take a closer look at how to use these features to tune your system.
|
||
|
||
Delayed Starting and/or Stopping of Pumps or Valves
|
||
***************************************************
|
||
|
||
For systems with pumps, it's generally a bad idea to run the pump with no distribution valves open.
|
||
This causes pressure to build up and can even destroy the pump after some time. For systems with (a)
|
||
pump(s), you'll likely want to add two configuration options:
|
||
|
||
.. code-block:: yaml
|
||
|
||
sprinkler:
|
||
- id: lawn_sprinkler_ctrlr
|
||
pump_start_pump_delay: 3s
|
||
pump_stop_valve_delay: 3s
|
||
...
|
||
|
||
This will cause any given pump to start (in this example) three seconds *after* any associated distribution
|
||
valve is opened. In addition, it will wait three seconds to close the *last* distribution valve *after*
|
||
the pump is stopped. This would allow the pump to spin down, pressure to drop and lines to drain prior
|
||
to switching off the (last) associated distribution valve. (In these configurations, it might also be
|
||
desirable to enable ``valve_overlap``, as well -- more on this below.)
|
||
|
||
Some types of electric valves require sufficient water pressure to (fully/quickly) close. These types of
|
||
valves, when coupled with electric valves upstream of distribution valves (often known in the industry as
|
||
"main" or "master" valves), may require that the upstream valve is switched on *before* any given distribution
|
||
valve(s), allowing the water pressure to stabilize and force all distribution valves closed *before* any single
|
||
distribution valve is opened. In these situations, the reverse of the above configuration may be desirable:
|
||
|
||
.. code-block:: yaml
|
||
|
||
sprinkler:
|
||
- id: lawn_sprinkler_ctrlr
|
||
pump_start_valve_delay: 3s
|
||
pump_stop_pump_delay: 3s
|
||
...
|
||
|
||
In this example, the upstream valve would open three seconds prior to any given associated distribution
|
||
valve, allowing the water pressure to force any attached distribution valves closed. After the delay, the
|
||
required distribution valve is opened and the cycle starts. When the cycle is complete, the (last) distribution
|
||
valve would be switched off three seconds prior to the upstream valve. (In these configurations, it might also
|
||
be desirable to enable ``valve_open_delay``, as well.)
|
||
|
||
.. note::
|
||
|
||
Using ``pump_stop_valve_delay`` or ``pump_stop_pump_delay`` with ``valve_open_delay`` and
|
||
``pump_switch_off_during_valve_open_delay`` may increase the off-time inserted between the operation
|
||
of each zone, as the controller must wait for a given zone (pump *and* valve) to fully shut down before
|
||
it can be started again.
|
||
|
||
Banging Pipes or Valves That Don't Consistently Close
|
||
*****************************************************
|
||
|
||
A common complaint people have with sprinkler systems is that of banging pipes. In other, less common situations,
|
||
some systems suffer from valves that do not (fully/quickly) close. There are three controller options available to
|
||
address either of these complaints/concerns:
|
||
|
||
- ``valve_overlap``
|
||
- ``valve_open_delay``
|
||
- ``pump_switch_off_during_valve_open_delay``
|
||
|
||
The first option, ``valve_overlap``, causes the current valve and the next valve (as the controller is iterating
|
||
through valves) to run simultaneously for the duration specified. The idea here is that this causes a reduction
|
||
in water pressure as the next zone starts up, therefore minimizing banging pipes (aka the "water hammer" effect)
|
||
when the valve that is finishing up finally closes.
|
||
|
||
The second and third options may be used to ensure sufficient water pressure is available to force valves closed.
|
||
This may be useful for pressure-sensitive valves that don't quickly and/or fully close when water pressure is low.
|
||
|
||
For systems with pumps, it may be desirable to switch off the pump before switching to the next distribution
|
||
valve/zone. In these situations, ``pump_switch_off_during_valve_open_delay`` may prove useful in conjunction
|
||
with ``valve_open_delay``.
|
||
|
||
In any case, the examples in the next section illustrate how/where to add these options into your configuration.
|
||
|
||
.. _sprinkler-controller-examples:
|
||
|
||
Controller Examples
|
||
-------------------
|
||
|
||
Single Controller, Single Valve, No Pump
|
||
****************************************
|
||
|
||
This first example illustrates a complete, single-valve system with no pump/upstream valve(s). It
|
||
could be useful for controlling a single valve independent of any other sprinkler controllers. A pump
|
||
could easily be added by adding the ``pump_switch_id`` parameter and a :ref:`switch <config-switch>`.
|
||
|
||
.. code-block:: yaml
|
||
|
||
esphome:
|
||
name: esp-sprinkler-controller
|
||
platform: ESP32
|
||
board: featheresp32
|
||
|
||
wifi:
|
||
ssid: "wifi_ssid"
|
||
password: "wifi_password"
|
||
|
||
logger:
|
||
|
||
sprinkler:
|
||
- id: garden_sprinkler_ctrlr
|
||
valves:
|
||
- valve_switch: "Flower Garden"
|
||
run_duration: 300s
|
||
valve_switch_id: garden_sprinkler_valve
|
||
|
||
switch:
|
||
- platform: gpio
|
||
id: garden_sprinkler_valve
|
||
pin: 5
|
||
|
||
Single Controller, Three Valves, No Pump
|
||
****************************************
|
||
|
||
This example illustrates a complete, simple three-valve system with no pump/upstream valve(s):
|
||
|
||
.. code-block:: yaml
|
||
|
||
esphome:
|
||
name: esp-sprinkler-controller
|
||
platform: ESP32
|
||
board: featheresp32
|
||
|
||
wifi:
|
||
ssid: "wifi_ssid"
|
||
password: "wifi_password"
|
||
|
||
logger:
|
||
|
||
sprinkler:
|
||
- id: lawn_sprinkler_ctrlr
|
||
main_switch: "Lawn Sprinklers"
|
||
auto_advance_switch: "Lawn Sprinklers Auto Advance"
|
||
reverse_switch: "Lawn Sprinklers Reverse"
|
||
multiplier_number: "Lawn Sprinkler Multiplier"
|
||
repeat_number: "Lawn Sprinkler Repeat"
|
||
valve_overlap: 5s
|
||
valves:
|
||
- valve_switch: "Front Lawn"
|
||
enable_switch: "Enable Front Lawn"
|
||
run_duration_number: "Front Yard Run Duration"
|
||
valve_switch_id: lawn_sprinkler_valve_sw0
|
||
- valve_switch: "Side Lawn"
|
||
enable_switch: "Enable Side Lawn"
|
||
run_duration_number: "Front Yard Run Duration"
|
||
valve_switch_id: lawn_sprinkler_valve_sw1
|
||
- valve_switch: "Back Lawn"
|
||
enable_switch: "Enable Back Lawn"
|
||
run_duration_number: "Front Yard Run Duration"
|
||
valve_switch_id: lawn_sprinkler_valve_sw2
|
||
|
||
switch:
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw0
|
||
pin: 0
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw1
|
||
pin: 2
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw2
|
||
pin: 4
|
||
|
||
Single Controller, Three Valves, Single Pump
|
||
********************************************
|
||
|
||
This example illustrates a complete three-valve system with a single pump/upstream valve:
|
||
|
||
.. code-block:: yaml
|
||
|
||
esphome:
|
||
name: esp-sprinkler-controller
|
||
platform: ESP32
|
||
board: featheresp32
|
||
|
||
wifi:
|
||
ssid: "wifi_ssid"
|
||
password: "wifi_password"
|
||
|
||
logger:
|
||
|
||
sprinkler:
|
||
- id: lawn_sprinkler_ctrlr
|
||
main_switch: "Lawn Sprinklers"
|
||
auto_advance_switch: "Lawn Sprinklers Auto Advance"
|
||
reverse_switch: "Lawn Sprinklers Reverse"
|
||
valve_open_delay: 5s
|
||
valves:
|
||
- valve_switch: "Front Lawn"
|
||
enable_switch: "Enable Front Lawn"
|
||
pump_switch_id: sprinkler_pump_sw
|
||
run_duration: 900s
|
||
valve_switch_id: lawn_sprinkler_valve_sw0
|
||
- valve_switch: "Side Lawn"
|
||
enable_switch: "Enable Side Lawn"
|
||
pump_switch_id: sprinkler_pump_sw
|
||
run_duration: 900s
|
||
valve_switch_id: lawn_sprinkler_valve_sw1
|
||
- valve_switch: "Back Lawn"
|
||
enable_switch: "Enable Back Lawn"
|
||
pump_switch_id: sprinkler_pump_sw
|
||
run_duration: 900s
|
||
valve_switch_id: lawn_sprinkler_valve_sw2
|
||
|
||
switch:
|
||
- platform: gpio
|
||
id: sprinkler_pump_sw
|
||
pin: 12
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw0
|
||
pin: 0
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw1
|
||
pin: 2
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw2
|
||
pin: 4
|
||
|
||
Single Controller, Three Latching Valves, Single Latching Pump
|
||
**************************************************************
|
||
|
||
This example is similar to the previous example, however it illustrates how a "latching" or "pulsed"
|
||
valve can be configured. This type of valve requires two :doc:`GPIO switches <switch/gpio>` to
|
||
operate -- one to switch the valve on and one to switch the valve off. To switch on the valve, the
|
||
"on" :doc:`GPIO switch <switch/gpio>` is switched on for the configured duration and then switched
|
||
off. To switch the valve off, the "off" :doc:`GPIO switch <switch/gpio>` is switched on for the
|
||
configured duration and then switched off.
|
||
|
||
Note that, while this example illustrates a configuration that uses exclusively latching valves,
|
||
latching and non-latching valves may be mixed and matched in any configuration, even if attached to
|
||
a common pump/upstream valve.
|
||
|
||
.. code-block:: yaml
|
||
|
||
esphome:
|
||
name: esp-sprinkler-controller
|
||
platform: ESP32
|
||
board: featheresp32
|
||
|
||
wifi:
|
||
ssid: "wifi_ssid"
|
||
password: "wifi_password"
|
||
|
||
logger:
|
||
|
||
sprinkler:
|
||
- id: lawn_sprinkler_ctrlr
|
||
main_switch: "Lawn Sprinklers"
|
||
auto_advance_switch: "Lawn Sprinklers Auto Advance"
|
||
queue_enable_switch: "Lawn Sprinklers Queue Enable"
|
||
reverse_switch: "Lawn Sprinklers Reverse"
|
||
pump_pulse_duration: 250ms
|
||
valve_pulse_duration: 250ms
|
||
valve_open_delay: 5s
|
||
valves:
|
||
- valve_switch: "Front Lawn"
|
||
enable_switch: "Enable Front Lawn"
|
||
pump_off_switch_id: sprinkler_pump_sw_off
|
||
pump_on_switch_id: sprinkler_pump_sw_on
|
||
run_duration: 900s
|
||
valve_off_switch_id: lawn_sprinkler_valve_sw0_off
|
||
valve_on_switch_id: lawn_sprinkler_valve_sw0_on
|
||
- valve_switch: "Side Lawn"
|
||
enable_switch: "Enable Side Lawn"
|
||
pump_off_switch_id: sprinkler_pump_sw_off
|
||
pump_on_switch_id: sprinkler_pump_sw_on
|
||
run_duration: 900s
|
||
valve_off_switch_id: lawn_sprinkler_valve_sw1_off
|
||
valve_on_switch_id: lawn_sprinkler_valve_sw1_on
|
||
- valve_switch: "Back Lawn"
|
||
enable_switch: "Enable Back Lawn"
|
||
pump_off_switch_id: sprinkler_pump_sw_off
|
||
pump_on_switch_id: sprinkler_pump_sw_on
|
||
run_duration: 900s
|
||
valve_off_switch_id: lawn_sprinkler_valve_sw2_off
|
||
valve_on_switch_id: lawn_sprinkler_valve_sw2_on
|
||
|
||
switch:
|
||
- platform: gpio
|
||
id: sprinkler_pump_sw_off
|
||
pin: 14
|
||
- platform: gpio
|
||
id: sprinkler_pump_sw_on
|
||
pin: 15
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw0_off
|
||
pin: 0
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw0_on
|
||
pin: 2
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw1_off
|
||
pin: 4
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw1_on
|
||
pin: 5
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw2_off
|
||
pin: 12
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw2_on
|
||
pin: 13
|
||
|
||
Dual Controller, Five Valves, Two Pumps
|
||
***************************************
|
||
|
||
This example illustrates a complete and more complex dual-controller system with a total of five
|
||
valves (three on the first controller and two on the second controller) and two pumps/upstream
|
||
valves, each of which are shared between the two controllers:
|
||
|
||
.. code-block:: yaml
|
||
|
||
esphome:
|
||
name: esp-sprinkler-controller
|
||
platform: ESP32
|
||
board: featheresp32
|
||
|
||
wifi:
|
||
ssid: "wifi_ssid"
|
||
password: "wifi_password"
|
||
|
||
logger:
|
||
|
||
sprinkler:
|
||
- id: lawn_sprinkler_ctrlr
|
||
main_switch: "Lawn Sprinklers"
|
||
auto_advance_switch: "Lawn Sprinklers Auto Advance"
|
||
reverse_switch: "Lawn Sprinklers Reverse"
|
||
valve_overlap: 5s
|
||
valves:
|
||
- valve_switch: "Front Lawn"
|
||
enable_switch: "Enable Front Lawn"
|
||
pump_switch_id: sprinkler_pump_sw0
|
||
run_duration: 900s
|
||
valve_switch_id: lawn_sprinkler_valve_sw0
|
||
- valve_switch: "Side Lawn"
|
||
enable_switch: "Enable Side Lawn"
|
||
pump_switch_id: sprinkler_pump_sw0
|
||
run_duration: 900s
|
||
valve_switch_id: lawn_sprinkler_valve_sw1
|
||
- valve_switch: "Back Lawn"
|
||
enable_switch: "Enable Back Lawn"
|
||
pump_switch_id: sprinkler_pump_sw1
|
||
run_duration: 900s
|
||
valve_switch_id: lawn_sprinkler_valve_sw2
|
||
- id: garden_sprinkler_ctrlr
|
||
main_switch: "Garden Sprinklers"
|
||
auto_advance_switch: "Garden Sprinklers Auto Advance"
|
||
reverse_switch: "Garden Sprinklers Reverse"
|
||
valve_open_delay: 5s
|
||
valves:
|
||
- valve_switch: "Front Garden"
|
||
enable_switch: "Enable Front Garden"
|
||
pump_switch_id: sprinkler_pump_sw0
|
||
run_duration_number:
|
||
id: garden_sprinkler_ctrlr_front_run_duration
|
||
name: "Front Garden Run Duration"
|
||
initial_value: 10
|
||
unit_of_measurement: min
|
||
valve_switch_id: garden_sprinkler_valve_sw0
|
||
- valve_switch: "Back Garden"
|
||
enable_switch: "Enable Back Garden"
|
||
pump_switch_id: sprinkler_pump_sw1
|
||
run_duration_number:
|
||
id: garden_sprinkler_ctrlr_back_run_duration
|
||
name: "Back Garden Run Duration"
|
||
initial_value: 10
|
||
unit_of_measurement: min
|
||
valve_switch_id: garden_sprinkler_valve_sw1
|
||
|
||
switch:
|
||
- platform: gpio
|
||
id: sprinkler_pump_sw0
|
||
pin: 12
|
||
- platform: gpio
|
||
id: sprinkler_pump_sw1
|
||
pin: 13
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw0
|
||
pin: 0
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw1
|
||
pin: 2
|
||
- platform: gpio
|
||
id: lawn_sprinkler_valve_sw2
|
||
pin: 4
|
||
- platform: gpio
|
||
id: garden_sprinkler_valve_sw0
|
||
pin: 14
|
||
- platform: gpio
|
||
id: garden_sprinkler_valve_sw1
|
||
pin: 15
|
||
|
||
.. note::
|
||
|
||
In this final complete configuration example, pump control is split among the two sprinkler
|
||
controller instances. This will behave as expected; multiple instances of the controller will
|
||
communicate to ensure any given pump is activated and deactivated only as necessary, even when
|
||
the controllers are operating simultaneously.
|
||
|
||
.. _sprinkler-controller-sprinkler_controller_numbers:
|
||
|
||
Using the Sprinkler Controller's Numbers
|
||
****************************************
|
||
|
||
The sprinkler controller can leverage ESPHome's/Home Assistant's :doc:`number </components/number/index>` component to
|
||
make valve run durations easily adjustable from the front end (Home Assistant).
|
||
|
||
.. code-block:: yaml
|
||
|
||
sprinkler:
|
||
- id: lawn_sprinkler_ctrlr
|
||
multiplier_number: "Lawn Sprinkler Multiplier"
|
||
repeat_number: "Lawn Sprinkler Repeat"
|
||
...
|
||
|
||
An added benefit of using :doc:`number </components/number/index>` components is that modified valve run durations,
|
||
multiplier and repeat values can persist across resets/reboots of the ESP device. If this is your desired behavior, you
|
||
should configure the :doc:`number </components/number/index>` components within your sprinkler controller configuration.
|
||
|
||
The sprinkler controller's implementation of the :doc:`number </components/number/index>` component is based on
|
||
ESPHome's :doc:`/components/number/index`, supporting all of its :ref:`configuration variables <config-number>` in
|
||
addition to a subset of the :doc:`Template Number Component's </components/number/template>` configuration variables,
|
||
including:
|
||
|
||
- ``initial_value`` (Defaults to 900 for valves, 1 for multiplier, 0 for repeat)
|
||
- ``max_value`` (Defaults to 86400 for valves, 10 for multiplier and repeat)
|
||
- ``min_value`` (Defaults to 1 for valves, 0 for multiplier and repeat)
|
||
- ``step`` (Defaults to 1 for valves and repeat, 0.1 for multiplier)
|
||
- ``restore_value`` (Defaults to ``true``; set to ``false`` to always restore ``initial_value`` at boot)
|
||
- ``set_action``
|
||
- ``unit_of_measurement`` (For run durations only; defaults to ``s`` for seconds or specify ``min`` for minutes)
|
||
|
||
Here's a brief example:
|
||
|
||
.. code-block:: yaml
|
||
|
||
sprinkler:
|
||
- id: lawn_sprinkler_ctrlr
|
||
main_switch: "Lawn Sprinklers"
|
||
...
|
||
multiplier_number:
|
||
id: controller_multiplier_number
|
||
name: "Lawn Sprinkler Multiplier"
|
||
initial_value: 1.5
|
||
min_value: 0.1
|
||
max_value: 5
|
||
set_action:
|
||
- lambda: "some_function();"
|
||
...
|
||
|
||
.. _sprinkler-controller-sprinkler_controller_extending_switches:
|
||
|
||
Extending the Sprinkler Controller's Switches
|
||
*********************************************
|
||
|
||
It is worth noting that each of the various switches in the sprinkler controller's configuration are standard
|
||
ESPHome :ref:`switch <config-switch>` components. Their configuration may be extended in a manner similar to
|
||
the following example:
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Extended switch configuration for 'main_switch'
|
||
sprinkler:
|
||
- id: sprinkler_ctrlr
|
||
main_switch:
|
||
name: "Lawn Sprinklers"
|
||
id: sprinkler_ctrlr_main_switch_id
|
||
on_turn_on:
|
||
light.turn_on: my_light
|
||
...
|
||
|
||
This arrangement is possible for any other switch within the sprinkler controller's configuration block, with
|
||
the exception of ``pump_off_switch_id``, ``pump_on_switch_id``, ``pump_switch_id``, ``valve_off_switch_id``,
|
||
``valve_on_switch_id`` and ``valve_switch_id`` (because these are the IDs of other switch components already
|
||
defined elsewhere in your configuration). In addition, specifying each switch ID enables the ability to refer
|
||
to any of the sprinkler controller's switches from elsewhere in your configuration. Here's another brief example:
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Template switch as a secondary main switch
|
||
switch:
|
||
- platform: template
|
||
id: my_switch
|
||
name: "My Special Sprinkler Switch"
|
||
on_turn_off:
|
||
- switch.turn_off: sprinkler_ctrlr_main_switch_id
|
||
- light.turn_off: sprinkler_indicator_light
|
||
on_turn_on:
|
||
- switch.turn_on: sprinkler_ctrlr_main_switch_id
|
||
- light.turn_on: sprinkler_indicator_light
|
||
...
|
||
|
||
While the above example simply illustrates creating a secondary "main" switch, this approach could be extended
|
||
to take advantage of other devices such as a moisture :ref:`sensor <config-sensor>` -- when the moisture level
|
||
is too low (look for ``on_value`` or ``on_value_range``), the sprinkler controller (or a specific valve) could
|
||
be activated by calling one of the controller's start-up actions, such as ``sprinkler.start_full_cycle``,
|
||
``sprinkler.start_from_queue``, ``sprinkler.start_single_valve``, or ``sprinkler.resume_or_start_full_cycle``.
|
||
|
||
.. _sprinkler-controller-sprinkler_controller_queue:
|
||
|
||
The Sprinkler Controller Queue
|
||
******************************
|
||
|
||
The queuing mechanism is an unusual feature for a sprinkler controller; it becomes useful as a result of the
|
||
extreme flexibility of both ESPHome and Home Assistant. Given the extensive ecosystem of devices available today,
|
||
the sprinkler controller's queuing mechanism provides an advanced feature aimed at allowing even more advanced automation.
|
||
|
||
In general, it comes down to flexibility: the more traditional "run full cycle" and "run single valve" functionality
|
||
is intended for use by humans (via the front end or physical control interface) while the queuing mechanism is aimed
|
||
at supporting automation.
|
||
|
||
Here's a practical example:
|
||
|
||
Consider a home with a yard divided into a number of sprinkler zones -- perhaps it even includes a garden or two
|
||
(flowers and vegetables, of course!). An array of soil moisture sensors could be deployed throughout the various
|
||
zones and gardens and when a given sensor falls below some defined threshold, that sensor's zone is entered into
|
||
the sprinkler controller's queue.
|
||
|
||
Then, each morning at some specific hour, Home Assistant (or even the ESP device itself!) calls the sprinkler
|
||
controller's ``sprinkler.start_from_queue`` action, causing the controller to iterate only through queued zones.
|
||
Because the run duration may be specified as a part of the queue request, this could be extended to compute a
|
||
specific run duration for each zone depending on the specific moisture level of the soil on any given day. The
|
||
possibilities are endless and are only limited by your creativity!
|
||
|
||
It is important to note that, if *both* the auto-advance and queue switches are turned on/enabled, **queued valves
|
||
take precedence over valves that would run as a part of a full cycle of the system.** In other words, if the queue
|
||
is enabled and a valve is entered into the queue while a full cycle is active, at the next valve transition, the
|
||
queue entry will be picked up *before* the next valve that would run as a part of the full cycle. At present, this
|
||
behavior cannot be changed. It should also be noted that the queue has a hard-coded limit of 100 entries to limit
|
||
memory use.
|
||
|
||
Expose Sprinkler Controller Actions via user-API
|
||
************************************************
|
||
|
||
This configuration snippet illustrates how user-defined ESPHome API services may be used to expose
|
||
various sprinkler controller actions to the front end. This could be useful to change settings
|
||
and/or trigger sprinkler controller actions using automations.
|
||
|
||
.. code-block:: yaml
|
||
|
||
api:
|
||
services:
|
||
- service: set_multiplier
|
||
variables:
|
||
multiplier: float
|
||
then:
|
||
- sprinkler.set_multiplier:
|
||
id: lawn_sprinkler_ctrlr
|
||
multiplier: !lambda 'return multiplier;'
|
||
- service: start_full_cycle
|
||
then:
|
||
- sprinkler.start_full_cycle: lawn_sprinkler_ctrlr
|
||
- service: start_single_valve
|
||
variables:
|
||
valve: int
|
||
then:
|
||
- sprinkler.start_single_valve:
|
||
id: lawn_sprinkler_ctrlr
|
||
valve_number: !lambda 'return valve;'
|
||
- service: next_valve
|
||
then:
|
||
- sprinkler.next_valve: lawn_sprinkler_ctrlr
|
||
- service: previous_valve
|
||
then:
|
||
- sprinkler.previous_valve: lawn_sprinkler_ctrlr
|
||
- service: shutdown
|
||
then:
|
||
- sprinkler.shutdown: lawn_sprinkler_ctrlr
|
||
|
||
.. _sprinkler-controller-sprinkler_controller_understanding_state:
|
||
|
||
Understanding the Sprinkler Controller's State
|
||
----------------------------------------------
|
||
|
||
A number of people have asked about how to determine the sprinkler controller's state. This section aims to outline how
|
||
to use the sprinkler controller's :apiref:`API <sprinkler/sprinkler.h>` to determine what it is doing, generally with
|
||
the goal of indicating this on some form of :doc:`display </components/display/index>` hardware. Note that this
|
||
discussion largely revolves around C++ code (as is used in ESPHome lambdas).
|
||
|
||
Many of the methods used to determine the sprinkler controller's state return a type of value known as an ``optional``.
|
||
If you are curious, a general reference for the ``optional`` type may be found
|
||
`here <https://en.cppreference.com/w/cpp/utility/optional>`__, but what is important for now is:
|
||
|
||
- The ``optional`` type *may* or *may not* contain a value
|
||
|
||
- The method ``has_value()`` is used to determine if a value is present. For example:
|
||
``id(lawn_sprinkler_ctrlr).active_valve().has_value()``
|
||
- The method ``value()`` is used to determine the value, *if* it is determined that a value is present. For example:
|
||
``auto running_valve = id(lawn_sprinkler_ctrlr).active_valve().value()``
|
||
|
||
- The ``optional`` type can contain a value of any C++ type (``bool``, ``int``, ``float``, etc.) (In C++ terms, it is a
|
||
template.)
|
||
|
||
The examples that follow illustrate use of the the sprinkler controller's methods within a
|
||
:doc:`display </components/display/index>` lambda. The examples are intended to illustrate a pattern and (for sake of
|
||
brevity) *are not complete*; at very least you'll need to fill out the :doc:`display </components/display/index>`
|
||
component's specific configuration details before you can use them.
|
||
|
||
With these points in mind, let's discuss some of the methods which indicate the state of the sprinkler controller.
|
||
We'll approach this from the angle of *"how do I..."*
|
||
|
||
.. _sprinkler-controller-sprinkler_controller_understanding_state_how_do_i:
|
||
|
||
How Do I...
|
||
***********
|
||
|
||
- **...determine if the sprinkler controller is running?**
|
||
|
||
Use the method ``optional<size_t> active_valve()`` to check if there is an active valve. If the ``optional`` returned
|
||
``has_value()``, the sprinkler controller is running and you may use the ``value()`` method to check which specific
|
||
valve is active.
|
||
|
||
*Example:*
|
||
|
||
.. code-block:: c++
|
||
|
||
display:
|
||
- platform: ...
|
||
# ...display configuration...
|
||
lambda: |-
|
||
if (id(lawn_sprinkler_ctrlr).active_valve().has_value()) {
|
||
// the controller is running, get the active valve into running_valve and print it
|
||
auto running_valve = id(lawn_sprinkler_ctrlr).active_valve().value();
|
||
it.printf(0, 0, "Valve %u active", running_valve);
|
||
} else {
|
||
// the controller is NOT running
|
||
it.print(0, 0, "Idle");
|
||
}
|
||
|
||
- **...determine if the sprinkler controller is paused and, if so, which valve is paused?**
|
||
|
||
Use the method ``optional<size_t> paused_valve()`` to check if there is a paused valve. If the ``optional`` returned
|
||
``has_value()``, the sprinkler controller is paused and you may use the ``value()`` method to check which specific
|
||
valve is paused. In general, this follows the same pattern as the
|
||
:ref:`active_valve() example above <sprinkler-controller-sprinkler_controller_understanding_state_how_do_i>`.
|
||
|
||
- **...determine the sprinkler controller's current mode?**
|
||
|
||
If by this you mean, "is auto-advance/the queue/reverse/standby enabled?", you are in the right spot. Methods exist
|
||
for just this purpose:
|
||
|
||
- ``bool auto_advance()``
|
||
- ``bool queue_enabled()``
|
||
- ``bool reverse()``
|
||
- ``bool standby()``
|
||
|
||
Each will return ``true`` if the respective "mode" is enabled.
|
||
|
||
*Examples:*
|
||
|
||
.. code-block:: c++
|
||
|
||
display:
|
||
- platform: ...
|
||
# ...display configuration...
|
||
lambda: |-
|
||
if (id(lawn_sprinkler_ctrlr).auto_advance()) {
|
||
// auto-advance is enabled
|
||
it.print(0, 0, "Auto-advance enabled");
|
||
} else {
|
||
// auto-advance is NOT enabled
|
||
it.print(0, 0, "Auto-advance disabled");
|
||
}
|
||
if (id(lawn_sprinkler_ctrlr).queue_enabled()) {
|
||
// queue is enabled
|
||
it.print(0, 10, "Queue enabled");
|
||
} else {
|
||
// queue is NOT enabled
|
||
it.print(0, 10, "Queue disabled");
|
||
}
|
||
|
||
- **...determine the sprinkler controller's multiplier/repeat values?**
|
||
|
||
Methods of interest in this case are:
|
||
|
||
- ``float multiplier()``
|
||
- ``optional<uint32_t> repeat()``
|
||
- ``optional<uint32_t> repeat_count()``
|
||
|
||
Note again that each of the ``repeat`` methods returns an ``optional`` type; if the ``optional`` returned
|
||
``has_value()``, repeating is enabled and you can get the repeat target (``repeat()``) or current repeat
|
||
count (``repeat_count()``) with ``optional``'s ``value()`` method.
|
||
|
||
The ``multiplier()`` method returns a ``float`` type and, as such, it always has a value.
|
||
|
||
*Examples:*
|
||
|
||
.. code-block:: c++
|
||
|
||
display:
|
||
- platform: ...
|
||
# ...display configuration...
|
||
lambda: |-
|
||
it.printf(0, 0, "Multiplier: %f", id(lawn_sprinkler_ctrlr).multiplier());
|
||
|
||
if (id(lawn_sprinkler_ctrlr).repeat().has_value()) {
|
||
// the controller is repeating, print the repeat target value
|
||
it.printf(0, 10, "Repeat %u times", id(lawn_sprinkler_ctrlr).repeat().value());
|
||
}
|
||
|
||
- **...determine how much time is left/required?**
|
||
|
||
Several methods are available for this purpose:
|
||
|
||
- ``uint32_t total_cycle_time_all_valves()``
|
||
- ``uint32_t total_cycle_time_enabled_valves()``
|
||
- ``uint32_t total_cycle_time_enabled_incomplete_valves()``
|
||
- ``uint32_t total_queue_time()``
|
||
- ``optional<uint32_t> time_remaining_active_valve()``
|
||
- ``optional<uint32_t> time_remaining_current_operation()``
|
||
|
||
Note that, as with several of the earlier examples, the ``time_remaining_...`` methods each return an ``optional``
|
||
type. If the ``optional`` returned ``has_value()``, a valve is active/running; if it does not ``has_value()``, no
|
||
valve is active, meaning the controller is idle.
|
||
|
||
*Example:*
|
||
|
||
.. code-block:: c++
|
||
|
||
display:
|
||
- platform: ...
|
||
# ...display configuration...
|
||
lambda: |-
|
||
if (id(lawn_sprinkler_ctrlr).time_remaining_active_valve().has_value()) {
|
||
// the controller is running, print the number of seconds remaining
|
||
it.printf(0, 0, "Time left: %u sec.", id(lawn_sprinkler_ctrlr).time_remaining_active_valve().value());
|
||
} else {
|
||
// the controller is NOT running
|
||
it.print(0, 0, "Idle");
|
||
}
|
||
|
||