IR Remote Climate
|
|
=================
|
|
|
|
.. seo::
|
|
:description: Controls a variety of compatible Climate devices via IR
|
|
:image: air-conditioner-ir.png
|
|
|
|
This climate component allows you to control compatible AC units by sending an infrared (IR)
|
|
control signal, just as the unit's handheld remote controller would.
|
|
|
|
.. figure:: images/climate-ui.png
|
|
:align: center
|
|
:width: 60.0%
|
|
|
|
There is a growing list of compatible units. If your unit is not listed below you should
|
|
submit a feature request (see FAQ).
|
|
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| Name | Platform name | Supports receiver |
|
|
| | | |
|
|
+=======================================+=====================+======================+
|
|
| Ballu | ``ballu`` | yes |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| Coolix | ``coolix`` | yes |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| Daikin | ``daikin`` | yes |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| Fujitsu General | ``fujitsu_general`` | yes |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| Hitachi | ``hitachi_ac344`` | yes |
|
|
| | ``hitachi_ac424`` | |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| :ref:`LG<climate_ir_lg>` | ``climate_ir_lg`` | yes |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| Mitsubishi | ``mitsubishi`` | |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| TCL112, Fuego | ``tcl112`` | yes |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| :ref:`Toshiba<toshiba>` | ``toshiba`` | yes |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| :ref:`Whirlpool<whirlpool>` | ``whirlpool`` | yes |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
| Yashima | ``yashima`` | |
|
|
+---------------------------------------+---------------------+----------------------+
|
|
|
|
This component requires that you have configured a :doc:`/components/remote_transmitter`.
|
|
|
|
Due to the unidirectional nature of IR remote controllers, this component cannot determine the
|
|
actual state of the device and will assume the state of the device is the latest state requested.
|
|
|
|
However, when receiver is supported, you can optionally add a :doc:`/components/remote_receiver`
|
|
component so the climate state will be tracked when it is operated with the original remote
|
|
controller unit.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
remote_transmitter:
|
|
pin: GPIO32
|
|
carrier_duty_percent: 50%
|
|
|
|
climate:
|
|
- platform: coolix # adjust to match your AC unit!
|
|
name: "Living Room AC"
|
|
|
|
Configuration Variables:
|
|
------------------------
|
|
|
|
- **name** (**Required**, string): The name for the climate device.
|
|
- **sensor** (*Optional*, :ref:`config-id`): The sensor that is used to measure the ambient
|
|
temperature. This is only for reporting the current temperature in the frontend.
|
|
- **supports_cool** (*Optional*, boolean): Enables setting cooling mode for this climate device. Defaults to ``true``.
|
|
- **supports_heat** (*Optional*, boolean): Enables setting heating mode for this climate device. Defaults to ``true``.
|
|
- **receiver_id** (*Optional*, :ref:`config-id`): The id of the remote_receiver if this platform supports
|
|
receiver. see: :ref:`ir-receiver_id`.
|
|
- All other options from :ref:`Climate <config-climate>`.
|
|
|
|
Advanced Options
|
|
----------------
|
|
|
|
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
|
|
- **transmitter_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the remote transmitter.
|
|
|
|
.. _ir-receiver_id:
|
|
|
|
Using a Receiver
|
|
----------------
|
|
|
|
.. note::
|
|
|
|
This is only supported with select climate devices, see "Supports receiver" in the table at the top of the page.
|
|
|
|
Optionally, some platforms can listen to data the climate device sends over infrared to update their state (
|
|
for example what mode the device is in). By setting up a :doc:`remote_receiver </components/remote_receiver>`
|
|
and passing its ID to the climate platform you can enable this mode.
|
|
|
|
When using a receiver it is recommended to put the IR receiver as close as possible to the equipment's
|
|
IR receiver.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
remote_receiver:
|
|
id: rcvr
|
|
pin:
|
|
number: GPIO14
|
|
inverted: true
|
|
mode: INPUT_PULLUP
|
|
# high 55% tolerance is recommended for some remote control units
|
|
tolerance: 55%
|
|
|
|
climate:
|
|
- platform: coolix
|
|
name: "Living Room AC"
|
|
receiver_id: rcvr
|
|
|
|
.. _climate_ir_lg:
|
|
|
|
``climate_ir_lg`` Climate
|
|
-------------------------
|
|
|
|
Additional configuration is available for this platform
|
|
|
|
|
|
Configuration variables:
|
|
|
|
- **header_high** (*Optional*, :ref:`config-time`): time for the high part of the header for the LG protocol. Defaults to ``8000us``
|
|
- **header_low** (*Optional*, :ref:`config-time`): time for the low part of the header for the LG protocol. Defaults to ``4000us``
|
|
- **bit_high** (*Optional*, :ref:`config-time`): time for the high part of any bit in the LG protocol. Defaults to ``600us``
|
|
- **bit_one_low** (*Optional*, :ref:`config-time`): time for the low part of a '1' bit in the LG protocol. Defaults to ``1600us``
|
|
- **bit_zero_low** (*Optional*, :ref:`config-time`): time for the low part of a '0' bit in the LG protocol. Defaults to ``550us``
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
climate:
|
|
- platform: climate_ir_lg
|
|
name: "AC"
|
|
sensor: room_temperature
|
|
header_high: 3265us # AC Units from LG in Brazil, for example use these timings
|
|
header_low: 9856us
|
|
|
|
|
|
.. _toshiba:
|
|
|
|
``toshiba`` Climate
|
|
-------------------
|
|
|
|
Additional configuration is available for this model.
|
|
|
|
|
|
Configuration variables:
|
|
|
|
- **model** (*Optional*, string): There are two valid models
|
|
|
|
- ``GENERIC``: Temperature range is from 17 to 30 (default)
|
|
- ``RAC-PT1411HWRU-C``: Temperature range is from 16 to 30; unit displays temperature in degrees Celsius
|
|
- ``RAC-PT1411HWRU-F``: Temperature range is from 16 to 30; unit displays temperature in degrees Fahrenheit
|
|
|
|
.. note::
|
|
|
|
- While they are identified as separate models here, the ``RAC-PT1411HWRU-C`` and ``RAC-PT1411HWRU-C`` are
|
|
in fact the same physical model/unit. They are separated here only because different IR codes are used
|
|
depending on the desired unit of measurement. This only affects how temperature is displayed on the unit itself.
|
|
|
|
- The ``RAC-PT1411HWRU`` model supports a feature Toshiba calls "Comfort Sense". The handheld remote control
|
|
has a built-in temperature sensor and it will periodically transmit the temperature from this sensor to the
|
|
AC unit. If a ``sensor`` is provided in the configuration with this model, the sensor's temperature will be
|
|
transmitted to the ``RAC-PT1411HWRU`` in the same manner as the original remote controller. How often the
|
|
temperature is transmitted is determined by the ``update_interval`` assigned to the ``sensor``. Note that
|
|
``update_interval`` must be less than seven minutes or the ``RAC-PT1411HWRU`` will revert to using its own
|
|
internal temperature sensor; a value of 30 seconds seems to work well. See :doc:`/components/sensor/index`
|
|
for more information.
|
|
|
|
|
|
.. _whirlpool:
|
|
|
|
|
|
``whirlpool`` Climate
|
|
---------------------
|
|
|
|
Additional configuration is available for this model.
|
|
|
|
|
|
Configuration variables:
|
|
|
|
- **model** (*Optional*, string): There are two valid models
|
|
|
|
- ``DG11J1-3A``: Temperature range is from 18 to 32 (default)
|
|
- ``DG11J1-91``: Temperature range is from 16 to 30
|
|
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :doc:`/components/climate/index`
|
|
- :doc:`/components/remote_receiver`
|
|
- :doc:`/components/remote_transmitter`
|
|
- :doc:`/components/sensor/index`
|
|
- :apiref:`ballu.h <ballu/ballu.h>`,
|
|
- :apiref:`coolix.h <coolix/coolix.h>`,
|
|
:apiref:`daikin.h <daikin/daikin.h>`
|
|
:apiref:`fujitsu_general.h <fujitsu_general/fujitsu_general.h>`,
|
|
:apiref:`hitachi_ac344.h <hitachi_ac344/hitachi_ac344.h>`,
|
|
:apiref:`mitsubishi.h <mitsubishi/mitsubishi.h>`,
|
|
:apiref:`tcl112.h <tcl112/tcl112.h>`,
|
|
:apiref:`yashima.h <yashima/yashima.h>`
|
|
:apiref:`whirlpool.h <whirlpool/whirlpool.h>`
|
|
:apiref:`climate_ir_lg.h <climate_ir_lg/climate_ir_lg.h>`
|
|