mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-12-30 18:09:26 +01:00
88e315e0e4
* Many example yaml tidy-ups * Update components/sensor/hlw8012.rst --------- Co-authored-by: Keith Burzinski <kbx81x@gmail.com>
133 lines
4.9 KiB
ReStructuredText
133 lines
4.9 KiB
ReStructuredText
Hydreon Rain Sensor
|
|
===================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up Hydreon rain sensors
|
|
:image: hydreon_rg9.jpg
|
|
:keywords: hydreon
|
|
|
|
The ``hydreon_rgxx`` sensor platform allows you to use rain sensors by Hydreon. Currently supported are the RG-9 and RG-15 sensors (`model comparison <https://rainsensors.com/products/model-comparison/>`_).
|
|
|
|
These optical rain sensors use a UART connection at 3.3V. The :ref:`UART <uart>` is
|
|
required to be set up in your configuration for this sensor to work.
|
|
|
|
Supported firmware versions:
|
|
- RG-15: v1.000
|
|
- RG-9: v1.000, v1.100, v1.200
|
|
|
|
Device FAQ: `<https://rainsensors.com/support/rg-9-rg-15-faq/>`__
|
|
|
|
.. figure:: images/hydreon_rg9_full.jpg
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
Hydreon RG-9 Rain Sensor. Image by `Hydreon <https://rainsensors.com/>`_.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example RG-9 entry
|
|
sensor:
|
|
- platform: hydreon_rgxx
|
|
model: RG_9
|
|
id: hydreon_1
|
|
moisture:
|
|
name: Rain Level
|
|
temperature:
|
|
name: Device Temperature
|
|
|
|
binary_sensor:
|
|
- platform: hydreon_rgxx
|
|
hydreon_rgxx_id: hydreon_1
|
|
too_cold:
|
|
name: Temperature Status
|
|
lens_bad:
|
|
name: Lens Status
|
|
em_sat:
|
|
name: Emitter Saturation
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example RG-15 entry
|
|
sensor:
|
|
- platform: hydreon_rgxx
|
|
model: RG_15
|
|
resolution: high
|
|
acc:
|
|
name: Rain
|
|
event_acc:
|
|
name: Rain Event"
|
|
total_acc:
|
|
name: Rain Total"
|
|
r_int:
|
|
name: Rain Intensity
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **model** (**Required**, string): Specify which rain sensor you have connected. Must be either ``RG_9`` or ``RG_15``.
|
|
|
|
- **disable_led** (*Optional*): Disables the on-board LED. Defaults to ``false``. Only on RG-9 firmware version 1.200-onwards.
|
|
|
|
|
|
- **uart_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the :ref:`UART Component <uart>` if you want
|
|
to use multiple UART buses.
|
|
|
|
- **moisture** (*Optional*): Rain intensity level from 0-7 (`more detail <https://rainsensors.com/support/rg-9-rg-15-faq/#RG-9RValue>`__). Only on RG-9.
|
|
|
|
- **name** (**Required**, string): The name for the sensor.
|
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **temperature** (*Optional*): Device internal temperature in Celsius. Accuracy is ±5°C. Only on RG-9 firmware version 1.100-onwards.
|
|
|
|
- **name** (**Required**, string): The name for the sensor.
|
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **resolution** (*Optional*, string): Specify rain sensor resolution. Must be either ``low`` or ``high``. Default resolution is ``high``.
|
|
Only applies to RG-15.
|
|
|
|
- **acc** (*Optional*): Amount of rain since last message (see ``update_interval``), in ``mm``. Only on RG-15.
|
|
|
|
- **name** (**Required**, string): The name for the sensor.
|
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **event_acc** (*Optional*): Amount of rain for this event (i.e. since it last stopped raining), in ``mm``. Only on RG-15.
|
|
|
|
- **name** (**Required**, string): The name for the sensor.
|
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **total_acc** (*Optional*): Total amount of rain this sensor has ever measured, in ``mm``. Only on RG-15.
|
|
|
|
- **name** (**Required**, string): The name for the sensor.
|
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **r_int** (*Optional*): Current rain intensity in ``mm/h``. Only on RG-15.
|
|
|
|
- **name** (**Required**, string): The name for the sensor.
|
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
|
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :ref:`sensor-filters`
|
|
- :doc:`../binary_sensor/hydreon_rgxx`
|
|
|
|
- `Hydreon RG-9 <https://rainsensors.com/products/rg-9/>`__
|
|
- `Hydreon RG-15 <https://rainsensors.com/products/rg-15/>`__
|
|
|
|
- `RG-15 V1.000 manual <https://rainsensors.com/wp-content/uploads/sites/3/2020/07/rg-15_instructions_sw_1.000.pdf>`__
|
|
|
|
- `RG-9 1.000 manual <https://rainsensors.com/wp-content/uploads/sites/3/2021/03/2020.08.25-rg-9_instructions.pdf>`__
|
|
- `RG-9 1.100 manual <https://rainsensors.com/wp-content/uploads/sites/3/2021/03/2021.03.11-rg-9_instructions.pdf>`__
|
|
- `RG-9 1.200 manual <https://rainsensors.com/wp-content/uploads/sites/3/2022/03/2022.02.17-rev-1.200-rg-9_instructions.pdf>`__
|
|
|
|
- :ghedit:`Edit`
|