Analog To Digital Sensor
|
|
========================
|
|
|
|
The Analog To Digital (``adc``) Sensor allows you to use the built-in
|
|
ADC in your device to measure a voltage on certain pins. On the ESP8266
|
|
only pin A0 (GPIO17) supports this. On the ESP32 pins GPIO32 through
|
|
GPIO39 can be used.
|
|
|
|
|image0|
|
|
|
|
.. code:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: adc
|
|
pin: A0
|
|
name: "Living Room Brightness"
|
|
update_interval: 15s
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- **pin** (**Required**,
|
|
`pin </esphomeyaml/configuration-types.html#pin>`__): The pin to
|
|
measure the voltage on.
|
|
- **name** (**Required**, string): The name of the voltage sensor.
|
|
- **attenuation** (*Optional*): Only on ESP32. Specify the `ADC
|
|
attenuation <http://esp-idf.readthedocs.io/en/latest/api-reference/peripherals/adc.html#_CPPv225adc1_config_channel_atten14adc1_channel_t11adc_atten_t>`__
|
|
to use. One of ``0db``, ``2.5db``, ``6db``, ``11db``. Defaults to
|
|
``0db``.
|
|
- **update_interval** (*Optional*,
|
|
`time </esphomeyaml/configuration-types.html#time>`__): The interval
|
|
to check the sensor. Defaults to ``15s``.
|
|
- **id** (*Optional*,
|
|
`id </esphomeyaml/configuration-types.html#id>`__): Manually specify
|
|
the ID used for code generation.
|
|
- All other options from
|
|
`Sensor </esphomeyaml/components/sensor/index.html#base-sensor-configuration>`__
|
|
and `MQTT
|
|
Component </esphomeyaml/components/mqtt.html#mqtt-component-base-configuration>`__.
|
|
|
|
.. |image0| image:: /esphomeyaml/components/sensor/images/adc.png
|
|
:class: align-center
|
|
:width: 80.0%
|
|
|
|
ESP32 Attenuation
|
|
~~~~~~~~~~~~~~~~~
|
|
|
|
On the ESP32, the voltage measured with the ADC caps out at 1.1V by default as the sensing range
|
|
or the attenuation of the ADC is set to ``0db`` by default.
|
|
|
|
To measure voltages higher than 1.1V, set ``attenuation`` to one of the following values:
|
|
|
|
- ``0db`` for a full-scale voltage of 1.1V (default)
|
|
- ``2.5db`` for a full-scale voltage of 1.5V
|
|
- ``6db`` for a full-scale voltage of 2.2V
|
|
- ``11db`` for a full-scale voltage of 3.9V
|