DHT Temperature+Humidity Sensor
===============================
The DHT Temperature+Humidity sensor allows you to use your DHT11
(`datasheet <https://akizukidenshi.com/download/ds/aosong/DHT11.pdf>`__,
`adafruit <https://www.adafruit.com/product/386>`__), DHT22
(`datasheet <https://www.sparkfun.com/datasheets/Sensors/Temperature/DHT22.pdf>`__,
`adafruit <https://www.adafruit.com/product/385>`__), AM2302
(`datasheet <https://cdn-shop.adafruit.com/datasheets/Digital+humidity+and+temperature+sensor+AM2302.pdf>`__,
`adafruit <https://www.adafruit.com/product/393>`__) and RHT03
(`datashet <https://cdn.sparkfun.com/datasheets/Sensors/Weather/RHT03.pdf>`__,
`sparkfun <https://cdn.sparkfun.com/datasheets/Sensors/Weather/RHT03.pdf>`__)
sensors with esphomelib.
.. figure:: /esphomeyaml/components/sensor/images/dht22-full.jpg
:align: center
:target: `Adafruit`_
:width: 50.0%
DHT22 Temperature & Humidity Sensor. Image by `Adafruit`_.
.. _Adafruit: https://www.adafruit.com/product/385
|image0|
.. |image0| image:: /esphomeyaml/components/sensor/images/temperature-humidity.png
:class: align-center
:width: 80.0%
.. code:: yaml
# Example configuration entry
sensor:
- platform: dht
pin: D2
temperature:
name: "Living Room Temperature"
humidity:
name: "Living Room Humidity"
update_interval: 15s
Configuration variables:
~~~~~~~~~~~~~~~~~~~~~~~~
- **pin** (**Required**, `pin </esphomeyaml/configuration-types.html#pin>`__): The pin where the DHT bus is connected.
- **temperature** (**Required**): The information for the temperature
sensor
- **name** (**Required**, string): The name for the temperature
sensor.
- All other options from
`Sensor </esphomeyaml/components/sensor/index.html#base-sensor-configuration>`__
and `MQTT
Component </esphomeyaml/components/mqtt.html#mqtt-component-base-configuration>`__.
- **humidity** (**Required**): The information for the humidity sensor
- **name** (**Required**, string): The name for the humidity sensor.
- All other options from
`Sensor </esphomeyaml/components/sensor/index.html#base-sensor-configuration>`__
and `MQTT
Component </esphomeyaml/components/mqtt.html#mqtt-component-base-configuration>`__.
- **model** (*Optional*, int): Manually specify the DHT model, can be
one of ``AUTO_DETECT``, ``DHT11``, ``DHT22``, ``AM2303``, ``RHT03``
and helps with some connection issues. Defaults to ``AUTO_DETECT``.
- **update_interval** (*Optional*, `time </esphomeyaml/configuration-types.html#time>`__): The interval to check the
sensor. Defaults to ``15s``.
- **id** (*Optional*, `id </esphomeyaml/configuration-types.html#id>`__): Manually specify the ID used for code
generation.
.. note::
If you're seeing lots of invalid temperature/humidity warnings in the logs, try manually setting the
DHT model with the ``model:`` configuration variable. Other problems could be wrong pull-up resistor values
on the DATA pin or too long cables.