mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-12-28 17:48:35 +01:00
189 lines
5.2 KiB
ReStructuredText
189 lines
5.2 KiB
ReStructuredText
AirThings BLE Sensors
|
|
=====================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up AirThings bluetooth-based sensors in ESPHome.
|
|
:keywords: AirThings, BLE, Bluetooth, Wave Plus, Wave Mini
|
|
|
|
The ``airthings_wave_plus`` and ``airthings_wave_mini`` sensor platforms lets you track the output of AirThings Bluetooth Low Energy devices.
|
|
|
|
This component will track radon, airborne chemicals, CO2, temperature and humidity and others depending on the device sensors.
|
|
|
|
Device Discovery
|
|
-----------------
|
|
|
|
AirThings devices can be found using the ``airthings_ble`` ble scanner.
|
|
|
|
To find out your device's MAC address, add the following to your ESPHome configuration:
|
|
|
|
.. code-block:: yaml
|
|
|
|
logger:
|
|
level: DEBUG # Required for the tracker to show the device
|
|
|
|
esp32_ble_tracker:
|
|
airthings_ble:
|
|
|
|
The device will then listen for nearby devices, and display a message like this one:
|
|
|
|
.. code-block:: text
|
|
|
|
[D][airthings_ble:019]:
|
|
Found AirThings device Serial: 123456789 (MAC: 01:02:03:04:05:06)
|
|
|
|
Once the device is found, remove the ``airthings_ble`` device tracker from your configuration and take note of the device MAC address, and use it when configuring a sensor below.
|
|
|
|
Supported Devices
|
|
-----------------
|
|
|
|
Airthings Wave Plus Sensor
|
|
**************************
|
|
|
|
AirThings Wave Plus tracks radon (24h and long term), airborne chemicals, CO2, temperature, atmospheric pressure and humidity.
|
|
|
|
.. figure:: images/airthings_wave_plus.jpg
|
|
:align: center
|
|
:width: 60.0%
|
|
|
|
Configuration example:
|
|
**********************
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
- platform: airthings_wave_plus
|
|
name: wave_plus
|
|
ble_client_id: airthings01
|
|
update_interval: 5min # default
|
|
battery_update_interval: 24h # default
|
|
temperature:
|
|
name: "WavePlus Temperature"
|
|
radon:
|
|
name: "WavePlus Radon"
|
|
radon_long_term:
|
|
name: "WavePlus Radon Long Term"
|
|
pressure:
|
|
name: "WavePlus Pressure"
|
|
humidity:
|
|
name: "WavePlus Humidity"
|
|
co2:
|
|
name: "WavePlus CO2"
|
|
tvoc:
|
|
name: "WavePlus VOC"
|
|
battery_voltage:
|
|
name: "WavePlus Battery Voltage"
|
|
|
|
ble_client:
|
|
- mac_address: 01:02:03:04:05:06
|
|
id: airthings01
|
|
|
|
esp32_ble_tracker:
|
|
|
|
Airthings Wave Mini Sensor
|
|
**************************
|
|
|
|
AirThings Wave Mini tracks airborne chemicals, temperature, pressure and humidity.
|
|
|
|
.. figure:: images/airthings_wave_mini.jpg
|
|
:align: center
|
|
:width: 60.0%
|
|
|
|
Configuration example:
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
- platform: airthings_wave_mini
|
|
ble_client_id: airthingsmini
|
|
update_interval: 5min # default
|
|
battery_update_interval: 24h # default
|
|
temperature:
|
|
name: "WaveMini Temperature"
|
|
pressure:
|
|
name: "WaveMini Pressure"
|
|
humidity:
|
|
name: "WaveMini Humidity"
|
|
tvoc:
|
|
name: "WaveMini VOC"
|
|
battery_voltage:
|
|
name: "WaveMini Battery Voltage"
|
|
|
|
ble_client:
|
|
- mac_address: 01:02:03:04:05:06
|
|
id: airthingsmini
|
|
|
|
esp32_ble_tracker:
|
|
|
|
.. note::
|
|
|
|
The sensor uses active polling of devices every 5 minutes as per the device reported internal refresh timeout.
|
|
|
|
.. note::
|
|
|
|
Battery-voltage reporting defaults to once every 24 hours in order
|
|
to reduce BLE traffic (obtaining the battery voltage requires quite
|
|
a few BLE commands/responses); if you wish to have it reported
|
|
more frequently configure the ``battery_update_interval``. The main
|
|
sensor ``update_interval`` controls the overall polling frequency
|
|
so setting the interval for the battery voltage to a lower value
|
|
will result in the battery voltage being reported once per polling
|
|
interval.
|
|
|
|
|
|
Battery Level Reporting
|
|
***********************
|
|
|
|
If you wish to have the 'percentage of battery life remaining'
|
|
reported as a sensor, you can make use of the :ref:`copy-sensor` component.
|
|
|
|
The examples below are based on standard alkaline-chemistry batteries;
|
|
if you use other types of batteries you may need to adjust the
|
|
reference voltages to obtain a proper 0-100% scale. The voltage
|
|
references were chosen to closely match the 0-100% range displayed by
|
|
the AirThings mobile app.
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
- platform: airthings_wave_mini
|
|
ble_client_id: airthingsmini
|
|
battery_voltage:
|
|
id: bv
|
|
name: "WaveMini Battery Voltage"
|
|
- platform: copy
|
|
source_id: bv
|
|
name: "WaveMini Battery Level"
|
|
unit_of_measurement: "%"
|
|
device_class: battery
|
|
accuracy_decimals: 0
|
|
filters:
|
|
- calibrate_linear:
|
|
- 2.7 -> 0
|
|
- 4.5 -> 100
|
|
|
|
.. code-block:: yaml
|
|
|
|
sensor:
|
|
- platform: airthings_wave_plus
|
|
ble_client_id: airthings01
|
|
battery_voltage:
|
|
id: bv
|
|
name: "WavePlus Battery Voltage"
|
|
- platform: copy
|
|
source_id: bv
|
|
name: "WavePlus Battery Level"
|
|
unit_of_measurement: "%"
|
|
device_class: battery
|
|
accuracy_decimals: 0
|
|
filters:
|
|
- calibrate_linear:
|
|
- 2.2 -> 0
|
|
- 3.1 -> 100
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :doc:`/components/esp32_ble_tracker`
|
|
- :ghedit:`Edit`
|