Over-the-Air Updates
|
|
====================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up the Over-The-Air (OTA) component to allow remote updating of devices.
|
|
:image: system-update.svg
|
|
|
|
.. _config-ota:
|
|
|
|
ESPHome supports remotely updating a device "over-the-air" (OTA). Each update mechanism is a *platform* of the base
|
|
``ota`` component and will have its own configuration variables.
|
|
|
|
In release 2024.6.0, the ``ota`` component transistioned from a standalone component to a *platform* component. This
|
|
change was made to facilitate the use of multiple update mechanisms, enabling greater flexibility.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
ota:
|
|
- platform: ...
|
|
|
|
Platforms
|
|
---------
|
|
|
|
.. toctree::
|
|
:maxdepth: 1
|
|
:glob:
|
|
|
|
*
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **on_begin** (*Optional*, :ref:`Automation<automation>`): An action to be performed when an OTA update is started.
|
|
See :ref:`ota-on_begin`.
|
|
- **on_progress** (*Optional*, :ref:`Automation<automation>`): An action to be performed (approximately each second)
|
|
while an OTA update is in progress. See :ref:`ota-on_progress`.
|
|
- **on_end** (*Optional*, :ref:`Automation<automation>`): An action to be performed after a successful OTA update.
|
|
See :ref:`ota-on_end`.
|
|
- **on_error** (*Optional*, :ref:`Automation<automation>`): An action to be performed after a failed OTA update.
|
|
See :ref:`ota-on_error`.
|
|
- **on_state_change** (*Optional*, :ref:`Automation<automation>`): An action to be performed when an OTA update state
|
|
change happens. See :ref:`ota-on_state_change`.
|
|
|
|
.. _ota-automations:
|
|
|
|
OTA Automations
|
|
---------------
|
|
|
|
The OTA component provides various :ref:`automations <automation>` that can be used to provide feedback during the OTA
|
|
update process. When using these automation triggers, note that:
|
|
|
|
- OTA updates block the main application loop while in progress. You won't be able to represent state changes using
|
|
components that update their output only from within their ``loop()`` method. Explained differently: if you try to
|
|
display the OTA progress using component X, but the update only appears after the OTA update finished, then component
|
|
X cannot be used for providing OTA update feedback.
|
|
- Your automation action(s) must not consume any significant amount of time; if they do, OTA updates may fail.
|
|
|
|
.. _ota-on_begin:
|
|
|
|
``on_begin``
|
|
************
|
|
|
|
This automation will be triggered when an OTA update is started.
|
|
|
|
.. code-block:: yaml
|
|
|
|
ota:
|
|
- platform: ...
|
|
on_begin:
|
|
then:
|
|
- logger.log: "OTA start"
|
|
|
|
.. _ota-on_progress:
|
|
|
|
``on_progress``
|
|
***************
|
|
|
|
Using this automation, it is possible to report on the OTA update progress. It will be triggered repeatedly during the
|
|
OTA update. You can get the actual progress percentage (a value between 0 and 100) from the trigger with variable ``x``.
|
|
|
|
.. code-block:: yaml
|
|
|
|
ota:
|
|
- platform: ...
|
|
on_progress:
|
|
then:
|
|
- logger.log:
|
|
format: "OTA progress %0.1f%%"
|
|
args: ["x"]
|
|
|
|
.. _ota-on_end:
|
|
|
|
``on_end``
|
|
**********
|
|
|
|
This automation will be triggered when an OTA update has completed successfully, immediately before the device is
|
|
rebooted.
|
|
|
|
Because the update has completed, you can safely use (an) automation action(s) that takes some time to complete. If,
|
|
for example, you want to flash an LED, multiple pauses/delays would be required to make the LED blink a few times,
|
|
before the reboot. The OTA update can't fail at this point because it is already complete.
|
|
|
|
.. code-block:: yaml
|
|
|
|
ota:
|
|
- platform: ...
|
|
on_end:
|
|
then:
|
|
- logger.log: "OTA end"
|
|
|
|
.. _ota-on_error:
|
|
|
|
``on_error``
|
|
************
|
|
|
|
This automation will be triggered when an OTA update has failed. You can get the internal error code with variable ``x``.
|
|
|
|
Just like for :ref:`ota-on_end`, you can safely use an automation that takes some time to complete as the OTA update
|
|
process has already finished.
|
|
|
|
.. code-block:: yaml
|
|
|
|
ota:
|
|
- platform: ...
|
|
on_error:
|
|
then:
|
|
- logger.log:
|
|
format: "OTA update error %d"
|
|
args: ["x"]
|
|
|
|
.. _ota-on_state_change:
|
|
|
|
``on_state_change``
|
|
*******************
|
|
|
|
This automation will be triggered on every state change. You can get the actual state with variable ``state``, which
|
|
will contain one of values for the ``OTAState`` enum. These values are:
|
|
|
|
- ``ota::OTA_STARTED``
|
|
- ``ota::OTA_IN_PROGRESS`` *(will be called repeatedly during the update)*
|
|
- ``ota::OTA_COMPLETED``
|
|
- ``ota::OTA_ERROR``
|
|
|
|
.. code-block:: yaml
|
|
|
|
ota:
|
|
- platform: ...
|
|
on_state_change:
|
|
then:
|
|
- if:
|
|
condition:
|
|
lambda: return state == ota::OTA_STARTED;
|
|
then:
|
|
- logger.log: "OTA start"
|
|
|
|
Safe Mode
|
|
---------
|
|
|
|
In addition to OTA updates, ESPHome also supports a "safe mode" to help with recovery if/when updates don't work as
|
|
expected. This is automatically enabled by the ``ota`` component, but it may be disabled if desired. See
|
|
:doc:`/components/safe_mode` for details.
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :apiref:`ota/ota_component.h`
|
|
- :doc:`/components/safe_mode`
|
|