Radon Eye BLE Sensors
=====================
.. seo::
:description: Instructions for setting up Radon Eye bluetooth-based sensors in ESPHome.
:keywords: Radon, RadonEye, RD200, BLE, Bluetooth, Wave Plus, Wave Mini
The ``radon_eye_rd200`` sensor platforms lets you track the output of Radon Eye RD200 Bluetooth Low Energy device.
This component will track radon concentration.
Device Discovery
-----------------
RadonEye devices can be found using the ``radon_eye_ble`` ble scanner.
To find out your device's MAC address, add the following to your ESPHome configuration:
.. code-block:: yaml
logger:
level: DEBUG # Required for the tracker to show the device
esp32_ble_tracker:
radon_eye_ble:
The device will then listen for nearby devices, and display a message like this one:
.. code-block:: text
[D][radon_eye_ble:017]:
Found Radon Eye RD200 device Name: FR:R20:SN1234 (MAC: 01:02:03:04:05:06)
Once the device is found, remove the ``radon_eye_ble`` device tracker from your configuration and
take note of the device MAC address, and use it when configuring a sensor below.
Supported Devices
-----------------
Radon Eye RD200 Sensor
**********************
Radon Eye RD200 tracks radon concentration over short periods (5 min interval) and longer periods
(24h or month).
The ``radon_long_term`` sensor is populated with the longest available measurement. The RD200
provides a 24hr measurement and a 1 month measurement.
If the 1 month isn't available, it will use
the 24hr. If the 24hr isn't available either, it will not publish the value.
.. figure:: images/radon_eye_rd200.jpg
:align: center
:width: 60.0%
Configuration example:
**********************
.. code-block:: yaml
esp32_ble_tracker:
ble_client:
- mac_address: 01:02:03:04:05:06
id: radon_eye_ble_id
sensor:
- platform: radon_eye_rd200
ble_client_id: radon_eye_ble_id
update_interval: 5min # default
radon:
name: "Radon"
radon_long_term:
name: "Radon Long Term"
Here is an example to use pCi/L (to match the value on the device display):
.. code-block:: yaml
esp32_ble_tracker:
ble_client:
- mac_address: 01:02:03:04:05:06
id: radon_eye_ble_id
sensor:
- platform: radon_eye_rd200
ble_client_id: radon_eye_ble_id
update_interval: 5min # default
radon:
name: "Radon"
unit_of_measurement: "pCi/L"
accuracy_decimals: 2
filters:
- lambda: return x / 37;
radon_long_term:
name: "Radon Long Term"
unit_of_measurement: "pCi/L"
accuracy_decimals: 2
filters: