Pulse Meter Sensor
==================
.. seo::
:description: Instructions for setting up pulse meter sensors.
:image: pulse.svg
The pulse meter sensor allows you to count the number and frequency of pulses on any pin. It is intended to be a drop-in replacement
for the :doc:`pulse counter component </components/sensor/pulse_counter>`.
Rather than counting pulses over a fixed time interval, the pulse meter sensor measures the time between pulses. The precise manner in which this is done depends on the ``internal_filter_mode`` option. This leads to a higher resolution, especially for low pulse rates, as the pulse counter sensor is limited by the number of pulses within a time interval.
Here's a comparison of the two sensors. The pulse meter is the smoother line. Both are set to an update interval of 10 seconds (using the ``update_interval`` and the ``throttle_average`` option respectively):
.. figure:: /images/pulse-counter_vs_pulse-meter.png
:align: center
:width: 50.0%
Please note that it is not possible to use both of these two sensors on the same pin at the same time.
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: pulse_meter
pin: GPIOXX
name: "Pulse Meter"
Configuration variables
------------------------
- **pin** (**Required**, :ref:`config-pin`): The pin to count pulses on.
- **name** (**Required**, string): The name of the sensor.
- **internal_filter** (*Optional*, :ref:`config-time`): If a pulse shorter than this time is detected, it is discarded. Defaults to ``13us``.
This acts as a debounce filter to eliminate input noise, so choose a value a little less than your expected minimum pulse width.
- **internal_filter_mode** (*Optional*, string): Determines how the internal filter is applied.
One of ``EDGE`` or ``PULSE``. Defaults to ``EDGE``.
- In ``EDGE`` mode, subsequent rising edges are compared and if they fall into an interval lesser than the ``internal filter`` value, the last one is discarded. This is useful if your input signal bounces, but is otherwise clean.
- In ``PULSE`` mode, the rising edge is discarded if any further interrupts are detected before the ``internal_filter`` time has passed. In other words, a high pulse must be at least ``internal_filter`` long to be counted. This is useful if you have a noisy input signal that may have bounces before and/or after the main pulse.
- **timeout** (*Optional*, :ref:`config-time`): If we don't see a pulse for this length of time, we assume *0 pulses/s*. Defaults to ``5 min``.
- **total** (*Optional*, :ref:`config-id`): An additional sensor that outputs the total number of pulses counted.
- All other options from :ref:`Sensor <config-sensor>`.
Converting units
----------------
The sensor defaults to units of *pulses/min*, You can change this by using :ref:`sensor-filters`.
For example, if youre using the pulse meter with a photodiode to count the light pulses on a power meter that has an impulse constant of *10000 pulses / kWh*, you can use the following to output instantaneous usage in *W*:
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: pulse_meter
name: 'Electricity Usage'
id: sensor_pulse_meter # Optional ID, necessary if you want to calculate the total number of pulses.
unit_of_measurement: 'W'
device_class: power
state_class: measurement
internal_filter: 20ms # Assuming maximum load of 16 kW and 10000 impulses per kWh, any pulses faster than 22.5 ms would exceed load. -10% ~= 20 ms.
accuracy_decimals: 0
pin: GPIOXX
filters:
- multiply: 6 # (60s / impulse constant) * (1000W / 1kW)
Counting total pulses
---------------------
When the total sensor is configured, ``pulse_meter`` also reports the total
number of pulses measured.
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: pulse_meter
# ...
total:
name: "Total Pulses"
(Re)Setting the total pulse count
---------------------------------
Using this action, you are able to reset/set the total pulse count. This can be useful
if you would like the ``total`` sensor to match what you see on your meter you are
trying to match.
.. code-block:: yaml
api:
services:
- service: set_total
variables:
new_total: int
then:
- pulse_meter.set_total_pulses:
id: sensor_pulse_meter
value: !lambda 'return new_total;'
.. note::
This value is the raw count of pulses, and not the value you see after the filters
See Also
--------
- :ref:`sensor-filters`
- :doc:`/components/sensor/pulse_counter`
- :doc:`/components/sensor/total_daily_energy`
- :doc:`/cookbook/power_meter`
- `Home Assistant Glow 🌟 <https://github.com/klaasnicolaas/home-assistant-glow/>`__.
- :apiref:`pulse_meter/pulse_meter_sensor.h`
- :ghedit:`Edit`