Midea Air Conditioner
=====================
.. seo::
:description: Instructions for setting up a Midea climate device
:image: air-conditioner.svg
The ``midea`` component creates a Midea air conditioner climate device.
.. note::
This protocol also used by some vendors:
- `Electrolux <https://www.electrolux.ru/>`_
- `Qlima <https://www.qlima.com/>`_
- `Artel <https://www.artelgroup.com/>`_
- `Carrier <https://www.carrier.com/>`_
- `Comfee <http://www.comfee-russia.ru/>`_
- `Inventor <https://www.inventorairconditioner.com/>`_
- `Senville <https://senville.com/>`_
- and maybe others
Control is possible with a custom dongle. Example of hardware implementation is `IoT Uni Dongle <https://github.com/dudanov/iot-uni-dongle>`_ or `Midea SLWF-01pro <https://smartlight.me/smart-home-devices/wifi-devices/wifi-dongle-air-conditioners-midea-idea-electrolux-for-home-assistant>`_ (`CloudFree <https://cloudfree.shop/product/ductless-hvac-wi-fi-module/>`_, `Tindie <https://www.tindie.com/products/smartlightme/wifi-dongle-for-air-conditioners-midea-electrolux>`_).
.. code-block:: yaml
# Example configuration entry
# Main settings
climate:
- platform: midea
name: Midea Climate # Use a unique name.
period: 1s # Optional
timeout: 2s # Optional
num_attempts: 3 # Optional
autoconf: true # Autoconfigure most options.
beeper: true # Beep on commands.
visual: # Optional. Example of visual settings override.
min_temperature: 17 °C # min: 17
max_temperature: 30 °C # max: 30
temperature_step: 0.5 °C # min: 0.5
supported_modes: # Optional. All capabilities in this section may be detected by autoconf.
- FAN_ONLY
- HEAT_COOL
- COOL
- HEAT
- DRY
custom_fan_modes: # Optional
- SILENT
- TURBO
supported_presets: # Optional. All capabilities in this section may be detected by autoconf.
- ECO
- BOOST
- SLEEP
custom_presets: # Optional. All capabilities in this section may be detected by autoconf.
- FREEZE_PROTECTION
supported_swing_modes: # Optional
- VERTICAL
- HORIZONTAL
- BOTH
outdoor_temperature: # Optional. Outdoor temperature sensor (may display incorrect values after long inactivity).
name: Temp
power_usage: # Optional. Power usage sensor (only for devices that support this feature).
name: Power
humidity_setpoint: # Optional. Indoor humidity sensor (only for devices that support this feature).
name: Humidity
Configuration variables:
------------------------
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
- **uart_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the :doc:`../uart` if you want
to use multiple UART buses.
- **name** (**Required**, string): The name of the climate device.
- **transmitter_id** (*Optional*, :ref:`config-id`): Defined and used automatically when using :doc:`../remote_transmitter` component for IR commands transmit.
- **period** (*Optional*, :ref:`config-time`): Minimal period between requests to the appliance. Defaults to ``1s``.
- **timeout** (*Optional*, :ref:`config-time`): Request response timeout until next request attempt. Defaults to ``2s``.
- **num_attempts** (*Optional*, int): Number of request attempts between 1 and 5 inclusive. Defaults to ``3``.
- **autoconf** (*Optional*, boolean): Get capabilities automatically. Allows you not to manually define most of the capabilities of the appliance.
Defaults to ``True``.
- **beeper** (*Optional*, boolean): Beeper feedback on command. Defaults to ``False``.
- **supported_modes** (*Optional*, list): List of supported modes. Possible values are: ``HEAT_COOL``, ``COOL``, ``HEAT``, ``DRY``, ``FAN_ONLY``.
- **custom_fan_modes** (*Optional*, list): List of supported custom fan modes. Possible values are: ``SILENT``, ``TURBO``.
- **supported_presets** (*Optional*, list): List of supported presets. Possible values are: ``ECO``, ``BOOST``, ``SLEEP``.
- **custom_presets** (*Optional*, list): List of supported custom presets. Possible values are: ``FREEZE_PROTECTION``.
- **supported_swing_modes** (*Optional*, list): List of supported swing modes. Possible values are: ``VERTICAL``, ``HORIZONTAL``, ``BOTH``.
- **outdoor_temperature** (*Optional*): The information for the outdoor temperature
sensor.
- **name** (**Required**, string): The name of the sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **power_usage** (*Optional*): The information for the current power consumption
sensor.
- **name** (**Required**, string): The name of the sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **humidity_setpoint** (*Optional*): The information for the humidity indoor
sensor (experimental).
- **name** (**Required**, string): The name of the sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- All other options from :ref:`Climate <config-climate>`.
Automations
-----------
.. _midea_ac-power_on_action:
``midea_ac.power_on`` Action
****************************
This action turn on power. The mode and preset will be restored to the last state before turned off.
.. code-block:: yaml
on_...:
then:
- midea_ac.power_on:
.. _midea_ac-power_off_action:
``midea_ac.power_off`` Action
*****************************
This action turn off power.
.. code-block:: yaml
on_...:
then:
- midea_ac.power_off:
.. _midea_ac-power_toggle_action:
``midea_ac.power_toggle`` Action
********************************
This action toggle the power state. Identical to pressing the power button on the remote control.
.. code-block:: yaml
on_...:
then:
- midea_ac.power_toggle:
.. _midea_ac-follow_me_action:
``midea_ac.follow_me`` Action
*****************************
This action transmit IR FollowMe command telling the air conditioner a more accurate
room temperature value to be used instead of the internal indoor unit sensor.
.. code-block:: yaml
on_...:
then:
- midea_ac.follow_me:
temperature: !lambda "return x;"
beeper: false
Configuration variables:
- **temperature** (**Required**, float, :ref:`templatable <config-templatable>`): Set the
value of a internal temperature sensor.
- **beeper** (*Optional*, boolean, :ref:`templatable <config-templatable>`): set beep on update.
Defaults to ``False``
.. _midea_ac-display_toggle_action:
``midea_ac.display_toggle`` Action
**********************************
This action toggle ac screen. Works via UART if supported or :doc:`../remote_transmitter`.
.. code-block:: yaml
on_...:
then:
- midea_ac.display_toggle:
.. _midea_ac-swing_step_action:
``midea_ac.swing_step`` Action
******************************
This action adjust the louver by one step. :doc:`../remote_transmitter` required.
.. code-block:: yaml
on_...:
then:
- midea_ac.swing_step:
.. _midea_ac-beeper_on_action:
``midea_ac.beeper_on`` Action
*****************************
This action turn on beeper feedback.
.. code-block:: yaml
on_...:
then:
- midea_ac.beeper_on:
.. _midea_ac-beeper_off_action:
``midea_ac.beeper_off`` Action
******************************
This action turn off beeper feedback.
.. code-block:: yaml
on_...:
then:
- midea_ac.beeper_off:
Additional control options using IR commands
--------------------------------------------
It is possible to use the FollowMe function and some other features available only through IR commands.
Below is an example of how to send FollowMe commands with the values of your sensor using the :doc:`../remote_transmitter`
component, as well as control the light of the LED display.
.. code-block:: yaml
# Example configuration entry
remote_transmitter:
pin: GPIO13 # For iot-uni-stick.
carrier_duty_percent: 100% # 50% for IR LED, 100% for direct connect to TSOP IR receiver output.
sensor:
- platform: homeassistant
entity_id: sensor.room_sensor # Sensor from HASS
internal: true
filters:
- throttle: 10s
- heartbeat: 2min # Maximum interval between updates.
- debounce: 1s
on_value:
midea_ac.follow_me:
temperature: !lambda "return x;"
beeper: false # Optional. Beep on update.
# template buttons for sending display control command and swing step actions
button:
- platform: template
name: Display Toggle
icon: mdi:theme-light-dark
on_press:
midea_ac.display_toggle:
- platform: template
name: Swing Step
icon: mdi:tailwind
on_press:
midea_ac.swing_step:
Example of Beeper Control Using a Switch
----------------------------------------
.. code-block:: yaml
switch:
- platform: template
name: Beeper
icon: mdi:volume-source
optimistic: true
turn_on_action:
midea_ac.beeper_on:
turn_off_action:
midea_ac.beeper_off:
Acknowledgments:
----------------
Thanks to the following people for their contributions to reverse engineering the UART protocol and source code in the following repositories:
* `Mac Zhou <https://github.com/mac-zhou/midea-msmart>`_
* `NeoAcheron <https://github.com/NeoAcheron/midea-ac-py>`_
* `Rene Klootwijk <https://github.com/reneklootwijk/midea-uart>`_
Special thanks to the project `IRremoteESP8266 <https://github.com/crankyoldgit/IRremoteESP8266>`_ for describing the IR protocol.
See Also
--------
- :doc:`/components/climate/index`
- :apiref:`climate/midea_ac.h`
- :ghedit:`Edit`