FTLab GDK101 Gamma Radiation Sensor Module
==========================================
.. seo::
:description: Instructions for setting up GDK101 Gamma Radiation Sensor Module
:image: gdk101.jpg
:keywords: gdk101
The **GDK101** sensor platform allows you to use your GDK101 sensor to monitor radiation levels at your place.
The GDK101 can measure average dose rate per 1 and 10 minutes, it also detect vibrations that can disturb the measurement.
The GDK101 requires setting up :ref:`I²C <i2c>` for data communication.
Module Pins
-----------
============ ===============================================================
Module Pin Description
============ ===============================================================
TX UART TX pin
RX UART RX pin
+5VIN Positive supply voltage
GND1 Ground
SDA I²C data bus
SCL I²C clock bus
A0 Adress Jumper 1
A1 Adress Jumper 2
============ ===============================================================
============ ===============================================================
I2C Address Jumpers State
============ ===============================================================
0x18 A0 Short, A1 Short
0x19 A0 Open, A1 Short
0x1A A0 Short, A1 Open
0x1B A0 Open, A1 Open
============ ===============================================================
.. figure:: images/gdk101.jpg
:align: center
:width: 50.0%
GDK101 Gamma Radiation Sensor Module.
Component/Hub
-------------
.. code-block:: yaml
# Example configuration entry
gdk101:
i2c_id: bus_a
address: 0x18
update_interval: 10s
- **address** (*Optional*, int): Manually specify the I²C address of
the sensor. Defaults to ``0x18`` (``A0`` and ``A1`` shorted).
The address is made up using the state of ``A0`` as bit 1 and the state of ``A1`` as bit 2, so a total of four addresses is possible.
- **update_interval** (*Optional*, int): Manually defined update iterval of sensor. Default to 60s.
- **i2c_id** (*Optional*, string): Optional name of the bus.
Sensor
------
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: gdk101
radiation_dose_per_1m:
name: "GDK101 Radiation Dose @ 1 min"
radiation_dose_per_10m:
name: "GDK101 Radiation Dose @ 10 min"
status:
name: "GDK101 Status"
version:
name: "GDK101 FW Version"
measurement_duration:
name: "GDK101 Measuring Time"
A sensor platform to radiation data
Configuration variables:
- **radiation_dose_per_1m** (**Required**): Radiation average dose per 1 minute.
All options from :ref:`Sensor <config-sensor>`.
- **radiation_dose_per_10m** (**Required**): Radiation average dose per 10 minutes.
All options from :ref:`Sensor <config-sensor>`.
- **version** (**Required**): Fimware version of the module.
All options from :ref:`Sensor <config-sensor>`.
- **status** (*Optional*): Sensor status.
All options from :ref:`Sensor <config-sensor>`.
- **measurement_duration** (*Optional*): Total time of measurement.
All options from :ref:`Sensor <config-sensor>`.
Binary Sensor
-------------
.. code-block:: yaml
# Example configuration entry
binary_sensor:
- platform: gdk101
vibrations:
name: "GDK101 Vibrations"
Binary sensor that indicates if measurement was disturbed by vibrations.
Configuration variables:
- **vibrations** (**Required**): Vibration status.
All options from :ref:`Binary Sensor <config-binary_sensor>`.
See Also
--------
- :ref:`sensor-filters`
- :apiref:`gdk101/gdk101.h`
- `Data Sheet <http://allsmartlab.com/eng/wp-content/uploads/sites/2/2017/01/GDK101datasheet_v1.6.pdf>`__
- `Application Notes <https://merona.blob.core.windows.net/radonftlab-web/GDK101.zip>`__
- `Arduino Sensors for Everyone blog post <https://arduino.steamedu123.com/entry/GDK101-Radiation-Sensor>`__
- :ghedit:`Edit`