Hydreon Rain Sensor Binary Sensor
|
|
=================================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up Hydreon rain sensors
|
|
:image: hydreon_rg9.jpg
|
|
:keywords: hydreon
|
|
|
|
The ``hydreon_rgxx`` binary sensor platform gives access to information provided by a Hydreon Rain Sensor.
|
|
For this sensor to work, a :doc:`/components/sensor/hydreon_rgxx` must be set up.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example RG-9 entry
|
|
|
|
uart:
|
|
rx_pin: GPIO16
|
|
tx_pin: GPIO17
|
|
baud_rate: 9600
|
|
|
|
sensor:
|
|
- platform: hydreon_rgxx
|
|
model: "RG_9"
|
|
id: "hydreon_1"
|
|
update_interval: 1s
|
|
moisture:
|
|
name: "rain"
|
|
expire_after: 30s
|
|
|
|
binary_sensor:
|
|
- platform: hydreon_rgxx
|
|
hydreon_rgxx_id: "hydreon_1"
|
|
too_cold:
|
|
name: "too cold"
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **hydreon_rgxx_id** (*Optional*, :ref:`config-id`): The ID of the Hydreon Rain Sensor display.
|
|
|
|
- **too_cold** (*Optional*): ``true`` if the sensor reports being too cold. Hydreon only mentions this feature for the RG-9.
|
|
|
|
- **name** (**Required**, string): The name for the voltage sensor.
|
|
|
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
|
|
|
- All other options from :ref:`Binary Sensor <config-binary_sensor>`.
|
|
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :doc:`/components/sensor/hydreon_rgxx`
|
|
- :doc:`index`
|
|
- :ghedit:`Edit`
|