esphome-docs/components/sensor/hm3301.rst
Evgeny 81cfdec0ce
AQI calculator for HM3301 (#535)
* AQI calculator for HM3301

* Update components/sensor/hm3301.rst

Co-authored-by: Guillermo Ruffino <glm.net@gmail.com>

* Update hm3301.rst

* pm1.0 not required

* format to look consistent with dht11

Co-authored-by: Guillermo Ruffino <glm.net@gmail.com>
2020-06-11 23:17:48 -03:00

88 lines
2.7 KiB
ReStructuredText

The Grove - Laser PM2.5 Sensor (HM3301)
=======================================
.. seo::
:description: Instructions for setting up HM3301 Particulate matter sensor
:image: hm3301.png
The ``HM3301`` sensor platform allows you to use your HM3301 particulate matter sensor
(`more info <http://wiki.seeedstudio.com/Grove-Laser_PM2.5_Sensor-HM3301>`__)
sensors with ESPHome.
The sensor communicate with board by ``I2C`` protocol, and requires 3.3v.
.. code-block:: yaml
# Example configuration entry
i2c:
sensor:
- platform: hm3301
pm_1_0:
name: "PM1.0"
pm_2_5:
name: "PM2.5"
pm_10_0:
name: "PM10.0"
aqi:
name: "AQI"
type: "CAQI"
Configuration variables:
------------------------
- **pm_1_0** (*Optional*): Use the concentration of particulates of size less than 1.0µm in µg per cubic meter.
- **name** (**Required**, string): The name for the temperature sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **pm_2_5** (*Optional*): Use the concentration of particulates of size less than 2.5µm in µg per cubic meter.
- **name** (**Required**, string): The name for the temperature sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **pm_10_0** (*Optional*): Use the concentration of particulates of size less than 10.0µm in µg per cubic meter.
- **name** (**Required**, string): The name for the temperature sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **aqi** (*Optional*): AQI sensor. Requires the ``pm_2_5`` and ``pm_10_0`` sensors defined. See below.
- **type** (**Required**): One of: ``AQI`` or ``CAQI``.
- **name** (**Required**, string): The name for the temperature sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
Air Quality Sensor:
-------------------
There is a sensor which calculates quality of air based on PM 2.5 and PM 10.0 values.
There are two implementations:
- AQI: USA air quality standard
- CAQI: Europe air quality standard
.. code-block:: yaml
sensor:
- platform: hm3301
pm_2_5:
name: "PM2.5"
pm_10_0:
name: "PM10.0"
aqi:
name: "AQI"
type: "CAQI"
See Also
--------
- :doc:`/components/sensor/sds011`
- :ref:`sensor-filters`
- :apiref:`hm3301/hm3301.h`
- :ghedit:`Edit`