Pulse Counter Sensor
|
||
====================
|
||
|
||
.. seo::
|
||
:description: Instructions for setting up pulse counter sensors.
|
||
:image: pulse.svg
|
||
|
||
The pulse counter sensor allows you to count the number of pulses and the frequency of a signal
|
||
on any pin.
|
||
|
||
On the ESP32, this sensor is even highly accurate because it's using the hardware `pulse counter
|
||
peripheral <https://docs.espressif.com/projects/esp-idf/en/latest/api-reference/peripherals/pcnt.html>`__
|
||
on the ESP32. However, due to the use of the pulse counter peripheral, a maximum of 8 channels can be used!
|
||
|
||
.. figure:: images/pulse-counter.png
|
||
:align: center
|
||
:width: 80.0%
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Example configuration entry
|
||
sensor:
|
||
- platform: pulse_counter
|
||
pin: 12
|
||
name: "Pulse Counter"
|
||
|
||
Configuration variables:
|
||
------------------------
|
||
|
||
- **pin** (**Required**, :ref:`config-pin`): The pin to count pulses on.
|
||
- **name** (**Required**, string): The name of the sensor.
|
||
- **count_mode** (*Optional*): Configure how the counter should behave
|
||
on a detected rising edge/falling edge.
|
||
|
||
- **rising_edge** (*Optional*): What to do when a rising edge is
|
||
detected. One of ``DISABLE``, ``INCREMENT`` and ``DECREMENT``.
|
||
Defaults to ``INCREMENT``.
|
||
- **falling_edge** (*Optional*): What to do when a falling edge is
|
||
detected. One of ``DISABLE``, ``INCREMENT`` and ``DECREMENT``.
|
||
Defaults to ``DISABLE``.
|
||
|
||
|
||
- **use_pcnt** (*Optional*, boolean): Use hardware ``PCNT`` pulse counter. Only supported on ESP32. Defaults to ``true``.
|
||
|
||
- **internal_filter** (*Optional*, :ref:`config-time`): If a pulse shorter than this
|
||
time is detected, it’s discarded and no pulse is counted. Defaults to ``13us``. On the ESP32, when using the hardware pulse counter
|
||
this value can not be higher than ``13us``, for the ESP8266 or with ``use_pcnt: false`` you can use larger intervals too.
|
||
If you enable this, set up the ``count_mode`` to increase on the falling edge, not leading edge. For S0 pulse meters that are used to meter power consumption 50-100 ms is a reasonable value.
|
||
|
||
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
||
|
||
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
|
||
|
||
- **total** (*Optional*): Report the total number of pulses.
|
||
|
||
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
||
.. note::
|
||
|
||
See :doc:`integration sensor </components/sensor/integration>` for summing up pulse counter
|
||
values over time.
|
||
|
||
Converting units
|
||
----------------
|
||
|
||
The sensor defaults to measuring its values using a unit of measurement
|
||
of “pulses/min”. You can change this by using :ref:`sensor-filters`.
|
||
For example, if you’re using the pulse counter with a photodiode to
|
||
count the light pulses on a power meter, you can do the following:
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Example configuration entry
|
||
sensor:
|
||
- platform: pulse_counter
|
||
pin: 12
|
||
unit_of_measurement: 'kW'
|
||
name: 'Power Meter House'
|
||
filters:
|
||
- multiply: 0.06 # (60s/1000 pulses per kWh)
|
||
|
||
|
||
Counting total pulses
|
||
---------------------
|
||
|
||
When the total sensor is configured, the pulse_counter also reports the total
|
||
number of pulses measured. When used on a power meter, this can be used to
|
||
measure the total consumed energy in kWh.
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Example configuration entry
|
||
sensor:
|
||
- platform: pulse_counter
|
||
pin: 12
|
||
unit_of_measurement: 'kW'
|
||
name: 'Power Meter House'
|
||
filters:
|
||
- multiply: 0.06 # (60s/1000 pulses per kWh)
|
||
|
||
total:
|
||
unit_of_measurement: 'kWh'
|
||
name: 'Energy Meter House'
|
||
filters:
|
||
- multiply: 0.001 # (1/1000 pulses per kWh)
|
||
|
||
(Re)Setting the total pulse count
|
||
---------------------------------
|
||
|
||
Using this action, you are able to reset/set the total pulse count. This can be useful
|
||
if you would like the ``total`` sensor to match what you see on your meter you are
|
||
trying to match.
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Set pulse counter total from home assistant using this service call:
|
||
api:
|
||
services:
|
||
- service: set_pulse_total
|
||
variables:
|
||
new_pulse_total: int
|
||
then:
|
||
- pulse_counter.set_total_pulses:
|
||
id: pulse_counter_id
|
||
value: !lambda 'return new_pulse_total;'
|
||
|
||
.. note::
|
||
|
||
This value is the raw count of pulses, and not the value you see after the filters
|
||
are applied.
|
||
|
||
Wiring
|
||
------
|
||
|
||
If you want to count pulses from a simple reed switch, the simplest way is to make
|
||
use of the internal pull-up/pull-down resistors.
|
||
|
||
You can wire the switch between a GPIO pin and GND; in this case set the pin to input, pullup and inverted:
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Reed switch between GPIO and GND
|
||
sensor:
|
||
- platform: pulse_counter
|
||
pin:
|
||
number: 12
|
||
inverted: true
|
||
mode:
|
||
input: true
|
||
pullup: true
|
||
name: "Pulse Counter"
|
||
|
||
If you wire it between a GPIO pin and +3.3V, set the pin to input, pulldown:
|
||
|
||
.. code-block:: yaml
|
||
|
||
# Reed switch between GPIO and +3.3V
|
||
sensor:
|
||
- platform: pulse_counter
|
||
pin:
|
||
number: 12
|
||
mode:
|
||
input: true
|
||
pulldown: true
|
||
name: "Pulse Counter"
|
||
|
||
The safest way is to use GPIO + GND, as this avoids the possibility of short
|
||
circuiting the wire by mistake.
|
||
|
||
See Also
|
||
--------
|
||
|
||
- :ref:`sensor-filters`
|
||
- :doc:`/components/sensor/pulse_meter`
|
||
- :doc:`rotary_encoder`
|
||
- `esp-idf Pulse Counter API <https://docs.espressif.com/projects/esp-idf/en/latest/api-reference/peripherals/pcnt.html>`__.
|
||
- :apiref:`pulse_counter/pulse_counter_sensor.h`
|
||