esphome-docs/components/sensor/hydreon_rgxx.rst

151 lines
5.3 KiB
ReStructuredText

Hydreon Rain Sensor
===================
.. seo::
:description: Instructions for setting up Hydreon rain sensors
:image: hydreon_rg9.jpg
:keywords: hydreon
The ``hydreon_rgxx`` sensor platform allows you to use rain sensors by Hydreon. Currently supported are the RG-9 and RG-15 sensors (`model comparison <https://rainsensors.com/products/model-comparison/>`_).
These optical rain sensors use a UART connection at 3.3V. The :ref:`UART <uart>` is
required to be set up in your configuration for this sensor to work.
Supported firmware versions:
- RG-15: v1.000
- RG-9: v1.000, v1.100, v1.200
Device FAQ: `<https://rainsensors.com/support/rg-9-rg-15-faq/>`__
.. figure:: images/hydreon_rg9_full.jpg
:align: center
:width: 50.0%
Hydreon RG-9 Rain Sensor. Image by `Hydreon <https://rainsensors.com/>`_.
.. code-block:: yaml
# Example RG-9 entry
uart:
rx_pin: GPIO16
tx_pin: GPIO17
baud_rate: 9600
sensor:
- platform: hydreon_rgxx
model: "RG_9"
id: "hydreon_1"
update_interval: 20s
disable_led: false
moisture:
name: "Rain Level"
temperature:
name: "Device Temperature"
binary_sensor:
- platform: hydreon_rgxx
hydreon_rgxx_id: "hydreon_1"
too_cold:
entity_category: diagnostic
name: "Temperature Status"
lens_bad:
entity_category: diagnostic
name: "Lens Status"
em_sat:
entity_category: diagnostic
name: "Emitter Saturation"
.. code-block:: yaml
# Example RG-15 entry
uart:
rx_pin: GPIO16
tx_pin: GPIO17
baud_rate: 9600
sensor:
- platform: hydreon_rgxx
model: "RG_15"
resolution: high
update_interval: 60s
acc:
name: "rain"
event_acc:
name: "rain event"
total_acc:
name: "rain total"
r_int:
name: "rain intensity"
Configuration variables:
------------------------
- **model** (**Required**, string): Specify which rain sensor you have connected. Must be either ``RG_9`` or ``RG_15``.
- **disable_led** (*Optional*): Disables the on-board LED. Defaults to ``false``. Only on RG-9 firmware version 1.200-onwards.
- **uart_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the :ref:`UART Component <uart>` if you want
to use multiple UART buses.
- **moisture** (*Optional*): Rain intensity level from 0-7 (`more detail <https://rainsensors.com/support/rg-9-rg-15-faq/#RG-9RValue>`__). Only on RG-9.
- **name** (**Required**, string): The name for the sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **temperature** (*Optional*): Device internal temperature in Celsius. Accuracy is ±5°C. Only on RG-9 firmware version 1.100-onwards.
- **name** (**Required**, string): The name for the sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **resolution** (*Optional*, string): Specify rain sensor resolution. Must be either ``low`` or ``high``. Default resolution is ``high``.
Only applies to RG-15.
- **acc** (*Optional*): Amount of rain since last message (see ``update_interval``), in ``mm``. Only on RG-15.
- **name** (**Required**, string): The name for the sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **event_acc** (*Optional*): Amount of rain for this event (i.e. since it last stopped raining), in ``mm``. Only on RG-15.
- **name** (**Required**, string): The name for the sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **total_acc** (*Optional*): Total amount of rain this sensor has ever measured, in ``mm``. Only on RG-15.
- **name** (**Required**, string): The name for the sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **r_int** (*Optional*): Current rain intensity in ``mm/h``. Only on RG-15.
- **name** (**Required**, string): The name for the sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
See Also
--------
- :ref:`sensor-filters`
- :doc:`../binary_sensor/hydreon_rgxx`
- `Hydreon RG-9 <https://rainsensors.com/products/rg-9/>`__
- `Hydreon RG-15 <https://rainsensors.com/products/rg-15/>`__
- `RG-15 V1.000 manual <https://rainsensors.com/wp-content/uploads/sites/3/2020/07/rg-15_instructions_sw_1.000.pdf>`__
- `RG-9 1.000 manual <https://rainsensors.com/wp-content/uploads/sites/3/2021/03/2020.08.25-rg-9_instructions.pdf>`__
- `RG-9 1.100 manual <https://rainsensors.com/wp-content/uploads/sites/3/2021/03/2021.03.11-rg-9_instructions.pdf>`__
- `RG-9 1.200 manual <https://rainsensors.com/wp-content/uploads/sites/3/2022/03/2022.02.17-rev-1.200-rg-9_instructions.pdf>`__
- :ghedit:`Edit`