Tuya Number
===========
.. seo::
:description: Instructions for setting up a Tuya device integer or enum datapoint..
:image: upload.svg
The ``tuya`` number platform allows you to create a number that controls
a tuya serial component. This platform requires :doc:`/components/tuya` to be configured.
When :doc:`/components/tuya` has been properly configured, it will output a list of
valid data points to the log after start-up.
.. code-block:: text
[21:37:14][C][tuya:028]: Tuya:
[21:37:14][C][tuya:045]: Datapoint 101: enum (value: 4)
[21:37:14][C][tuya:045]: Datapoint 102: enum (value: 1)
[21:37:14][C][tuya:041]: Datapoint 103: int value (value: 5)
[21:37:14][C][tuya:039]: Datapoint 104: switch (value: OFF)
[21:37:14][C][tuya:041]: Datapoint 105: int value (value: 229)
[21:37:14][C][tuya:041]: Datapoint 106: int value (value: 37)
[21:37:14][C][tuya:041]: Datapoint 107: int value (value: 10)
[21:37:14][C][tuya:041]: Datapoint 108: int value (value: 35)
[21:37:14][C][tuya:041]: Datapoint 109: int value (value: 30)
[21:37:14][C][tuya:041]: Datapoint 110: int value (value: 80)
[21:37:14][C][tuya:039]: Datapoint 112: switch (value: OFF)
[21:37:14][C][tuya:039]: Datapoint 113: switch (value: OFF)
[21:37:14][C][tuya:039]: Datapoint 114: switch (value: OFF)
[21:37:14][C][tuya:045]: Datapoint 115: enum (value: 4)
[21:37:14][C][tuya:045]: Datapoint 116: enum (value: 2)
[21:37:14][C][tuya:055]: Product: '{"p":"ymf4oruxqx0xlogp","v":"1.0.3","m":0}'
The example output above from a Tuya Siren with temperature and humidity sensors. The
``tuya`` number platform can be used to control all of the integer and enum datapoints.
On this device, datapoint 116 represents the volume control, with valid values being
0=High, 1=Medium, 2=Low.
Based on this, you can create a number as follows:
.. code-block:: yaml
- platform: "tuya"
name: "Volume"
number_datapoint: 116
min_value: 0
max_value: 2
step: 1
The value for ``multiply`` is used as the scaling factor for the Number. All numbers in Tuya are integers, so a scaling factor is sometimes needed to convert the Tuya reported value into floating point.
For instance, assume we have a pH sensor that reads from 0.00 to 15.00 with a scaling of 0.01. By setting ``multiply`` to 100, on the Tuya side (not visible to the user) the number will be reported as an integer from 0 to 1500. The following configuration could be used:
.. code-block:: yaml
- platform: "tuya"
name: "pH Sensor"
number_datapoint: 106
min_value: 0.00
max_value: 15.00
multiply: 100
Configuration variables:
------------------------
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
- **name** (**Required**, string): The name of the switch.
- **number_datapoint** (**Required**, int): The datapoint id number of the number.
- **min_value** (**Required**, float): The minimum value this number can be.
- **max_value** (**Required**, float): The maximum value this number can be.
- **step** (*Optional*, float): The granularity with which the number can be set. Defaults to 1.
- **multiply** (*Optional*, float): multiply the new value with this factor before sending the requests.
- All other options from :ref:`Number <config-number>`.