SUN_GTIL2 Grid Tie Inverter
|
|
===========================
|
|
|
|
.. seo::
|
|
:description: Instructions for reading data from a SUN-1000G2 grid tie inverter using ESPHome
|
|
:keywords: sun-1000g2, sun-2000g2, sun1000, sun2000, sun-1000gtil2, sun-2000gtil2
|
|
|
|
The ``sun_gtil2`` component allows you to get voltage, power and temperature readings from your ``SUN-1000G2``
|
|
or ``SUN-2000G2`` grid tie inverter. This is done by reading the UART data transmitted from the inverter's
|
|
controller board to the display board.
|
|
|
|
.. note::
|
|
|
|
You need to open your inverter to apply this modification. Use at your own risk! If you want to connect your
|
|
inverter via the (more limited) external RS232 interface you should use the
|
|
:doc:`Modbus </components/modbus_controller>` component instead.
|
|
|
|
.. figure:: images/sun_gtil2_controller_board.png
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
Pinout of the inverter's controller board
|
|
|
|
.. figure:: images/sun_gtil2_display_board.png
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
Pinout of the inverter's display board
|
|
|
|
.. figure:: images/sun_gtil2_schematic.png
|
|
:align: center
|
|
:width: 75.0%
|
|
|
|
Simplified connection diagram
|
|
|
|
As the data is read from the inverter using UART, you need to have an :ref:`UART bus <uart>` in your
|
|
configuration with the ``rx_pin`` connected to the TX pin of the inverter's controller board. Additionally, you
|
|
need to set the ``baud_rate`` to 9600.
|
|
|
|
|
|
|
|
The inverter will report new measurements approximately every 1.3 seconds.
|
|
|
|
Component/Hub
|
|
-------------
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sun_gtil2:
|
|
uart_id: control_to_display
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- **id** (**Required**, :ref:`config-id`): The id to use for this component.
|
|
- **uart_id** (*Optional*): The UART Bus ID for receiving messages sent from the inverter's controller to the display.
|
|
|
|
Sensor
|
|
------
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: sun_gtil2
|
|
temperature:
|
|
id: gtil_temperature
|
|
name: "Heatsink Temperature"
|
|
filters:
|
|
- throttle_average: 30s
|
|
dc_voltage:
|
|
id: gtil_dc_voltage
|
|
name: "DC Voltage"
|
|
filters:
|
|
- throttle_average: 30s
|
|
ac_voltage:
|
|
id: gtil_ac_voltage
|
|
name: "AC Voltage"
|
|
filters:
|
|
- throttle_average: 30s
|
|
ac_power:
|
|
id: gtil_ac_power
|
|
name: "AC Power"
|
|
dc_power:
|
|
id: gtil_dc_power
|
|
name: "DC Power"
|
|
limiter_power:
|
|
id: gtil_limiter_power
|
|
internal: True
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- **sun_gtil2_id** (*Optional*): Manually specify the ID of the sun_gtil2 instance if there are multiple.
|
|
|
|
- **temperature** (*Optional*): The temperature of your inverter's heatsink.
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **dc_voltage** (*Optional*): The voltage of your DC source. (battery or solar panels)
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **ac_voltage** (*Optional*): The grid voltage measured by the inverter.
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **dc_power** (*Optional*): The inverter's input power.
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **ac_power** (*Optional*): The inverter's output power.
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
- **limiter_power** (*Optional*): The power measured by the inverter's "Internal" limiter.
|
|
All options from :ref:`Sensor <config-sensor>`.
|
|
|
|
Text Sensor
|
|
-----------
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
text_sensor:
|
|
- platform: sun_gtil2
|
|
state:
|
|
id: gtil_state
|
|
name: "State"
|
|
serial_number:
|
|
id: gtil_serial_number
|
|
internal: True
|
|
|
|
Configuration variables:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- **sun_gtil2_id** (*Optional*): Manually specify the ID of the sun_gtil2 instance if there are multiple.
|
|
|
|
- **state** (*Optional*): The inverter's state.
|
|
All options from :ref:`Text Sensor <config-text_sensor>`.
|
|
|
|
- **serial_number** (*Optional*): The inverter's serial number.
|
|
All options from :ref:`Text Sensor <config-text_sensor>`.
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :ref:`sensor-filters`
|
|
- :ghedit:`Edit`
|