mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-12-26 17:27:47 +01:00
144 lines
5.9 KiB
ReStructuredText
144 lines
5.9 KiB
ReStructuredText
Modbus Controller Select
|
|
========================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up Modbus Controller Select(s) with ESPHome.
|
|
|
|
The ``modbus_controller`` Select platform allows you to create a Select from modbus
|
|
registers.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
select:
|
|
- platform: modbus_controller
|
|
name: "Modbus Select Register 1000"
|
|
address: 1000
|
|
value_type: U_WORD
|
|
optionsmap:
|
|
"Zero": 0
|
|
"One": 1
|
|
"Two": 2
|
|
"Three": 3
|
|
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
- **name** (**Required**, string): The name of the Select.
|
|
- **address**: (**Required**, int): The start address of the first or only register
|
|
of the Select.
|
|
- **optionsmap**: (**Required**, Map[str, int]): Provide a mapping from options (str) of
|
|
this Select to values (int) of the modbus register and vice versa. All options and
|
|
all values have to be unique.
|
|
- **value_type**: (*Optional*): The datatype of the modbus data. Defaults to ``U_WORD``.
|
|
- ``U_WORD`` (unsigned 16 bit integer from 1 register = 16bit)
|
|
- ``S_WORD`` (signed 16 bit integer from 1 register = 16bit)
|
|
- ``U_DWORD`` (unsigned 32 bit integer from 2 registers = 32bit)
|
|
- ``S_DWORD`` (signed 32 bit integer from 2 registers = 32bit)
|
|
- ``U_DWORD_R`` (unsigned 32 bit integer from 2 registers low word first)
|
|
- ``S_DWORD_R`` (signed 32 bit integer from 2 registers low word first)
|
|
- ``U_QWORD`` (unsigned 64 bit integer from 4 registers = 64bit)
|
|
- ``S_QWORD`` (unsigned 64 bit integer from 4 registers = 64bit)
|
|
- ``U_QWORD_R`` (unsigned 64 bit integer from 4 registers low word first)
|
|
- ``U_QWORD_R`` (signed 64 bit integer from 4 registers low word first)
|
|
- **register_count**: (*Optional*): The number of registers which are used for this Select. Only
|
|
required for uncommon response encodings or to
|
|
:ref:`optimize modbus communications<modbus_register_count>`. Overrides the defaults determined
|
|
by ``value_type``.
|
|
- **skip_updates**: (*Optional*, int): By default all sensors of of a modbus_controller are
|
|
updated together. For data points that don't change very frequently updates can be skipped. A
|
|
value of 5 would only update this sensor range in every 5th update cycle. Defaults to ``0``.
|
|
Note: The modbus_controller merges several registers into groups which are updated together. For
|
|
each group the smallest update cycle is used.
|
|
- **force_new_range**: (*Optional*, boolean): If possible sensors with sequential addresses are
|
|
grouped together and requested in one range. Setting this to ``true`` enforces the start of a new
|
|
range at that address.
|
|
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
|
|
- **lambda** (*Optional*, :ref:`lambda <config-lambda>`): Lambda to be evaluated every update interval
|
|
to get the current option of the select.
|
|
- **write_lambda** (*Optional*, :ref:`lambda <config-lambda>`): Lambda to be evaluated on every update
|
|
of the Sensor, before the new value is written to the modbus registers.
|
|
- **use_write_multiple**: (*Optional*, boolean): By default the modbus command ``Preset Single Registers``
|
|
(function code 6) is used for setting the holding register if only 1 register is set. If your device only supports *Preset Multiple Registers* (function code 16) set this option to ``true``. Defaults
|
|
to ``false``.
|
|
- All other options from :ref:`Select <config-select>`.
|
|
|
|
|
|
Parameters passed into ``lambda``
|
|
---------------------------------
|
|
|
|
- **x** (``int64_t``): The parsed integer value of the modbus data.
|
|
- **data** (``const std::vector<uint8_t>&``): vector containing the complete raw modbus response bytes for this
|
|
sensor. Note: because the response contains data for all registers in the same range you have to
|
|
use ``data[item->offset]`` to get the first response byte for your sensor.
|
|
- **item** (``ModbusSelect*const``): The sensor object itself.
|
|
|
|
Possible return values for the lambda:
|
|
|
|
- ``return <std::string>;`` The new option for this Select.
|
|
- ``return {};`` Use default mapping (see ``optionsmap``).
|
|
|
|
.. code-block:: yaml
|
|
|
|
# example
|
|
lambda: |-
|
|
ESP_LOGD("Reg1000", "Received value %lld", x);
|
|
ESP_LOGD("Reg1000", "Parsed from bytes 0x%x;0x%x", data[item->offset], data[item->offset + 1]);
|
|
if (x > 3) {
|
|
return std::string("Three");
|
|
}
|
|
|
|
|
|
Parameters passed into ``write_lambda``
|
|
---------------------------------------
|
|
|
|
- **x** (``const std::string&``): The option value to set for this Select.
|
|
- **value** (``int64_t``): The mapping value of ``x`` using ``optionsmap``.
|
|
- **payload** (``std::vector<uint16_t>& payload``): Empty vector for the payload. The lamdba can add
|
|
16 bit raw modbus register words which are send to the modbus device.
|
|
- **item** (``ModbusSelect*const``): The sensor object itself.
|
|
|
|
Possible return values for the lambda:
|
|
|
|
- ``return <int64_t>;`` the value which should be written to the configured modbus registers. If there were data written to ``payload`` this value is ignored.
|
|
- ``return {};`` Skip updating the register.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# example
|
|
write_lambda: |-
|
|
ESP_LOGD("Reg1000", "Set option to %s (%lld)", x.c_str(), value);
|
|
|
|
// re-use default option value from optionsmap
|
|
if (value == 0) {
|
|
return value;
|
|
}
|
|
|
|
// return own option value
|
|
if (x == "One") {
|
|
return 2;
|
|
}
|
|
|
|
// write payload
|
|
if (x == "Two") {
|
|
payload.push_back(0x0001);
|
|
return 0; // any value will do
|
|
}
|
|
|
|
// ignore update
|
|
return {};
|
|
|
|
|
|
See Also
|
|
--------
|
|
- :doc:`/components/modbus_controller`
|
|
- :doc:`/components/sensor/modbus_controller`
|
|
- :doc:`/components/binary_sensor/modbus_controller`
|
|
- :doc:`/components/switch/modbus_controller`
|
|
- :doc:`/components/text_sensor/modbus_controller`
|
|
- :doc:`/components/output/modbus_controller`
|
|
- :ref:`automation`
|
|
- https://www.modbustools.com/modbus.html
|
|
- :ghedit:`Edit`
|