esphome-docs/components/sensor/total_daily_energy.rst
Jesse Hills 9892a0fce9
[sensor] Tidy up name/id (#4150)
* [sensor] Tidy up name/id

* Add missing line

* Add missing line to sen5x
2024-08-13 21:33:05 -05:00

84 lines
2.6 KiB
ReStructuredText

Total Daily Energy Sensor
=========================
.. seo::
:description: Instructions for setting up sensors that track the total daily energy usage per day and accumulate the power usage.
:image: sigma.svg
The ``total_daily_energy`` sensor is a helper sensor that can use the power value of
other sensors like the :doc:`HLW8012 <hlw8012>`, :doc:`CSE7766 <cse7766>`, :doc:`ATM90E32 <atm90e32>`, etc and integrate
it over time.
So this component allows you to convert readings in ``W`` or ``kW`` to readings of the total
daily energy usage in ``Wh`` or ``kWh``.
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: total_daily_energy
name: 'Total Daily Energy'
power_id: my_power
unit_of_measurement: 'kWh'
state_class: total_increasing
device_class: energy
accuracy_decimals: 3
filters:
# Multiplication factor from W to kW is 0.001
- multiply: 0.001
# The power sensor to convert, can be any power sensor
- platform: hlw8012
# ...
power:
id: my_power
# Enable time component to reset energy at midnight
time:
- platform: homeassistant
id: homeassistant_time
Configuration variables:
------------------------
- **power_id** (**Required**, :ref:`config-id`): The ID of the power sensor
to integrate over time.
- **restore** (*Optional*, boolean): Whether to store the intermediate result on the device so
that the value can be restored upon power cycle or reboot.
Defaults to ``true``.
- **method** (*Optional*, string): The method to use for calculating the total daily energy. One of
``trapezoid``, ``left`` or ``right``. Defaults to ``right``.
- All other options from :ref:`Sensor <config-sensor>`.
Converting from W to kW
-----------------------
Some sensors such as the :doc:`HLW8012 <hlw8012>` expose their power sensor with a unit of measurement of
``W``. To have your readings in ``kW``, use a filter:
.. code-block:: yaml
sensor:
# The power sensor to convert, can be any power sensor
- platform: hlw8012
# ...
power:
id: my_power
filters:
# Multiplication factor from W to kW is 0.001
- multiply: 0.001
unit_of_measurement: kW
See Also
--------
- :ref:`sensor-filters`
- :doc:`hlw8012`
- :doc:`cse7766`
- :doc:`/components/sensor/pulse_counter`
- :doc:`/components/sensor/pulse_meter`
- :doc:`/components/time/homeassistant`
- :doc:`/cookbook/power_meter`
- :apiref:`total_daily_energy/total_daily_energy.h`
- :ghedit:`Edit`