esphome-docs/components/sensor/havells_solar.rst
2023-04-24 09:45:44 +12:00

185 lines
7.4 KiB
ReStructuredText

Havells Solar
=============
.. seo::
:description: Instructions for setting up Havells inverter reading on modbus.
:image: havellsgti5000d_s.jpg
:keywords: Havells Enviro, Havells GTI
The ``Havells Inverter`` sensor platform allows you to use Havells inverter data reading on modbus
(`website <https://www.havells.com/en/consumer/solar/solar-on-grid-inverter-and-solutions/solar-on-grid-inverter.html>`__)
with ESPHome.
.. figure:: images/havellsgti5000d.jpg
:align: center
:width: 50.0%
Havells On Grid Solar Inverter.
The communication with this integration is done over a :ref:`UART bus <uart>` using :ref:`Modbus <modbus>`.
You must therefore have a ``uart:`` entry in your configuration with both the TX and RX pins set
to some pins on your board and the baud rate set to 9600.
.. code-block:: yaml
# Example configuration entry
uart:
- id: modbus_uart
baud_rate: 9600
tx_pin: GPIO1
rx_pin: GPIO3
modbus:
uart_id: modbus_uart
flow_control_pin: GPIO4
sensor:
- platform: havells_solar
update_interval: 60s
phase_a:
voltage:
name: "HAVELLS Phase A Voltage"
current:
name: "HAVELLS Phase A Current"
phase_b:
voltage:
name: "HAVELLS Voltage Phase B"
current:
name: "HAVELLS Current Phase B"
phase_c:
voltage:
name: "HAVELLS Voltage Phase C"
current:
name: "HAVELLS Current Phase C"
pv1:
voltage:
name: "HAVELLS PV1 Voltage"
current:
name: "HAVELLS PV1 Current"
active_power:
name: "HAVELLS PV1 Active Power"
voltage_sampled_by_secondary_cpu:
name: "HAVELLS PV1 Voltage Sampled By Slave CPU"
insulation_of_p_to_ground:
name: "HAVELLS PV1 Insulation Of +VE To Ground"
pv2:
voltage:
name: "HAVELLS PV2 Voltage"
current:
name: "HAVELLS PV2 Current"
active_power:
name: "HAVELLS PV2 Active Power"
voltage_sampled_by_secondary_cpu:
name: "HAVELLS PV2 Voltage Sampled By Slave CPU"
insulation_of_p_to_ground:
name: "HAVELLS PV2 Insulation Of +VE To Ground"
active_power:
name: "HAVELLS Active Power"
reactive_power:
name: "HAVELLS Reactive Power"
frequency:
name: "HAVELLS Frequency"
energy_production_day:
name: "HAVELLS Today's Generation"
total_energy_production:
name: "HAVELLS Total Energy Production"
total_generation_time:
name: "HAVELLS Total Generation Time"
today_generation_time:
name: "HAVELLS Today Generation Time"
inverter_module_temp:
name: "HAVELLS Inverter Module Temp"
inverter_inner_temp:
name: "HAVELLS Inverter Inner Temp"
inverter_bus_voltage:
name: "HAVELLS Inverter BUS Voltage"
insulation_of_pv_n_to_ground:
name: "HAVELLS Insulation Of PV- To Ground"
gfci_value:
name: "HAVELLS GFCI Value"
dci_of_r:
name: "HAVELLS DCI Of R"
dci_of_s:
name: "HAVELLS DCI Of S"
dci_of_t:
name: "HAVELLS DCI Of T"
Configuration variables:
------------------------
- **phase_a** (*Optional*): The group of exposed sensors for Phase A/1.
- **current** (*Optional*): Use the current value of the sensor in amperes. All options from
:ref:`Sensor <config-sensor>`.
- **voltage** (*Optional*): Use the voltage value of the sensor in volts.
All options from :ref:`Sensor <config-sensor>`.
- **phase_b** (*Optional*): The group of exposed sensors for Phase B/2 on applicable inverters.
- All options from **phase_a**
- **phase_c** (*Optional*): The group of exposed sensors for Phase C/3 on applicable inverters.
- All options from **phase_a**
- **pv1** (*Optional*): The group of exposed sensors for Photo Voltaic 1.
- **current** (*Optional*): Use the current value of the sensor in amperes. All options from
:ref:`Sensor <config-sensor>`.
- **voltage** (*Optional*): Use the voltage value of the sensor in volts.
All options from :ref:`Sensor <config-sensor>`.
- **active_power** (*Optional*): Use the (active) power value of the sensor in watts. All options
from :ref:`Sensor <config-sensor>`.
- **voltage_sampled_by_secondary_cpu** (*Optional*): Use the photo voltiac's voltage sampled by
slave CPU value of the sensor in volts. All options from :ref:`Sensor <config-sensor>`.
- **insulation_of_p_to_ground** (*Optional*): Use the insulation of photo voltiac's +ve terminal to
ground value of the sensor in kilo ohms. All options from :ref:`Sensor <config-sensor>`.
- **pv2** (*Optional*): The group of exposed sensors for Photo Voltaic 2.
- All options from **pv1**
- **active_power** (*Optional*): Use the (active) power value of the sensor in watts. All options
from :ref:`Sensor <config-sensor>`.
- **reactive_power** (*Optional*): Use the reactive power value of the sensor in VAR. All
options from :ref:`Sensor <config-sensor>`.
- **frequency** (*Optional*): Use the frequency value of the sensor in hertz.
All options from :ref:`Sensor <config-sensor>`.
- **energy_production_day** (*Optional*): Use the export active energy value for same day of the
sensor in kilo watt hours. All options from :ref:`Sensor <config-sensor>`.
- **total_energy_production** (*Optional*): Use the total exported energy value of the sensor in
kilo watt hours. All options from :ref:`Sensor <config-sensor>`.
- **total_generation_time** (*Optional*): Use the total generation time value of the sensor in
hours. All options from :ref:`Sensor <config-sensor>`.
- **today_generation_time** (*Optional*): Use the day generation time value for same day of the
sensor in minutes. All options from :ref:`Sensor <config-sensor>`.
- **inverter_module_temp** (*Optional*): Use the inverter module temperature value of the sensor in
degree celsius. All options from :ref:`Sensor <config-sensor>`.
- **inverter_inner_temp** (*Optional*): Use the inverter inner temperature value of the sensor in
degree celsius. All options from :ref:`Sensor <config-sensor>`.
- **inverter_bus_voltage** (*Optional*): Use the inverter bus voltage value of the sensor in volts.
All options from :ref:`Sensor <config-sensor>`.
- **insulation_of_pv_n_to_ground** (*Optional*): Use the insulation of photo voltiacs's
-ve terminal to ground value of the sensor in kilo ohms. All options from :ref:`Sensor <config-sensor>`.
- **gfci_value** (*Optional*): Use the GFCI value of the sensor.
All options from :ref:`Sensor <config-sensor>`.
- **dci_of_r** (*Optional*): Use the DCI of R value of the sensor.
All options from :ref:`Sensor <config-sensor>`.
- **dci_of_s** (*Optional*): Use the DCI of S value of the sensor.
All options from :ref:`Sensor <config-sensor>`.
- **dci_of_t** (*Optional*): Use the DCI of T value of the sensor.
All options from :ref:`Sensor <config-sensor>`.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
sensor. Defaults to ``60s``.
- **address** (*Optional*, int): The address of the sensor if multiple sensors are attached to
the same UART bus. You will need to set the address of each device manually. Defaults to ``1``.
See Also
--------
- :ref:`sensor-filters`
- :ghedit:`Edit`