esphome-docs/components/sensor/ade7953.rst
2019-10-20 19:23:59 +02:00

120 lines
3.8 KiB
ReStructuredText

ADE7953 Power Sensor
====================
.. seo::
:description: Instructions for setting up ADE7953 power sensors
:image: ade7953.png
.. note::
This page is incomplete and could some work. If you want to contribute, please read the
:doc:`contributing guide </guides/contributing>`. This page is missing:
- A complete configuration example for the Shelly 2.5
- An image for the front page
The ``ade7953`` sensor platform allows you to use ADE7953 single phase energy metering ICs
(`datasheet <https://www.analog.com/media/en/technical-documentation/data-sheets/ADE7953.pdf>`__)
with ESPHome. These are commonly found in **Shelly 2.5** devices.
This sensor can measure voltage and has two channels for reading current and active power (A & B).
The :ref:`I²C Bus <i2c>` is
required to be set up in your configuration for this sensor to work.
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: ade7953
voltage:
name: ADE7953 Voltage
current_a:
name: ADE7953 Current A
current_b:
name: ADE7953 Current B
active_power_a:
name: ADE7953 Active Power A
active_power_b:
name: ADE7953 Active Power B
update_interval: 60s
Configuration variables:
------------------------
- **address** (*Optional*, int): Manually specify the i^2c address of the sensor. Defaults to ``0x38``.
- **voltage** (*Optional*): Use the voltage value of the sensor in volt. All options from
:ref:`Sensor <config-sensor>`.
- **current_a** (*Optional*): Use the current value of the A channel in amperes. All options from
:ref:`Sensor <config-sensor>`.
- **current_b** (*Optional*): Use the current value of the B channel in amperes. All options from
:ref:`Sensor <config-sensor>`.
- **active_power_a** (*Optional*): Use the power value of the A channel in watts. All options from
:ref:`Sensor <config-sensor>`.
- **active_power_b** (*Optional*): Use the power value of the A channel in watts. All options from
:ref:`Sensor <config-sensor>`.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
Use with Shelly 2.5
-------------------
The Shelly 2.5 device contains this sensor for power monitoring. An example config for the Shelly 2.5
is given below.
There are two oddities with the Shelly 2.5:
- First, the A and B channels are mixed up - the chip's A channel is label B on the outside and
vice versa. Probably to make the PCB easier to manufacture.
- Secondly, due to the first point the active_power values are inverted. This is fixed by
using a multiply filter as seen in the config below.
Additionally, the device has an ::doc:`NTC temperature sensor <ntc>`.
.. code-block:: yaml
i2c:
sda: GPIO12
scl: GPIO14
sensor:
- platform: ade7953
voltage:
name: Shelly Voltage
current_a:
name: Shelly Current B
current_b:
name: Shelly Current A
active_power_a:
name: Shelly Active Power B
filters:
- multiply: -1
active_power_b:
name: Shelly Active Power A
filters:
- multiply: -1
update_interval: 60s
# NTC Temperature
- platform: ntc
sensor: temp_resistance_reading
name: "Shelly Temperature"
calibration:
b_constant: 3350
reference_resistance: 10kOhm
reference_temperature: 298.15K
- platform: resistance
id: temp_resistance_reading
sensor: temp_analog_reading
configuration: DOWNSTREAM
resistor: 32kOhm
- platform: adc
id: temp_analog_reading
pin: A0
See Also
--------
- :ref:`sensor-filters`
- :apiref:`ade7953/ade7953.h`
- :ghedit:`Edit`