Add OpenTherm component (part 2.1: sensor platform) (#7529)

Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
This commit is contained in:
Oleg Tarasov 2024-10-25 05:00:28 +03:00 committed by GitHub
parent 33fdbbe30c
commit 21cb941bbe
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194
12 changed files with 933 additions and 37 deletions

View File

@ -1,9 +1,10 @@
from typing import Any
from esphome import pins
import esphome.codegen as cg
import esphome.config_validation as cv
from esphome import pins
from esphome.const import CONF_ID, PLATFORM_ESP32, PLATFORM_ESP8266
from . import generate
CODEOWNERS = ["@olegtarasov"]
MULTI_CONF = True
@ -15,15 +16,14 @@ CONF_DHW_ENABLE = "dhw_enable"
CONF_COOLING_ENABLE = "cooling_enable"
CONF_OTC_ACTIVE = "otc_active"
CONF_CH2_ACTIVE = "ch2_active"
CONF_SUMMER_MODE_ACTIVE = "summer_mode_active"
CONF_DHW_BLOCK = "dhw_block"
CONF_SYNC_MODE = "sync_mode"
opentherm_ns = cg.esphome_ns.namespace("opentherm")
OpenthermHub = opentherm_ns.class_("OpenthermHub", cg.Component)
CONFIG_SCHEMA = cv.All(
cv.Schema(
{
cv.GenerateID(): cv.declare_id(OpenthermHub),
cv.GenerateID(): cv.declare_id(generate.OpenthermHub),
cv.Required(CONF_IN_PIN): pins.internal_gpio_input_pin_schema,
cv.Required(CONF_OUT_PIN): pins.internal_gpio_output_pin_schema,
cv.Optional(CONF_CH_ENABLE, True): cv.boolean,
@ -31,6 +31,8 @@ CONFIG_SCHEMA = cv.All(
cv.Optional(CONF_COOLING_ENABLE, False): cv.boolean,
cv.Optional(CONF_OTC_ACTIVE, False): cv.boolean,
cv.Optional(CONF_CH2_ACTIVE, False): cv.boolean,
cv.Optional(CONF_SUMMER_MODE_ACTIVE, False): cv.boolean,
cv.Optional(CONF_DHW_BLOCK, False): cv.boolean,
cv.Optional(CONF_SYNC_MODE, False): cv.boolean,
}
).extend(cv.COMPONENT_SCHEMA),
@ -39,8 +41,6 @@ CONFIG_SCHEMA = cv.All(
async def to_code(config: dict[str, Any]) -> None:
# Create the hub, passing the two callbacks defined below
# Since the hub is used in the callbacks, we need to define it first
var = cg.new_Pvariable(config[CONF_ID])
await cg.register_component(var, config)
@ -53,5 +53,7 @@ async def to_code(config: dict[str, Any]) -> None:
non_sensors = {CONF_ID, CONF_IN_PIN, CONF_OUT_PIN}
for key, value in config.items():
if key not in non_sensors:
cg.add(getattr(var, f"set_{key}")(value))
if key in non_sensors:
continue
cg.add(getattr(var, f"set_{key}")(value))

View File

@ -0,0 +1,5 @@
OPENTHERM = "opentherm"
CONF_OPENTHERM_ID = "opentherm_id"
SENSOR = "sensor"

View File

@ -0,0 +1,140 @@
from collections.abc import Awaitable
from typing import Any, Callable
import esphome.codegen as cg
from esphome.const import CONF_ID
from . import const
from .schema import TSchema
opentherm_ns = cg.esphome_ns.namespace("opentherm")
OpenthermHub = opentherm_ns.class_("OpenthermHub", cg.Component)
def define_has_component(component_type: str, keys: list[str]) -> None:
cg.add_define(
f"OPENTHERM_{component_type.upper()}_LIST(F, sep)",
cg.RawExpression(
" sep ".join(map(lambda key: f"F({key}_{component_type.lower()})", keys))
),
)
for key in keys:
cg.add_define(f"OPENTHERM_HAS_{component_type.upper()}_{key}")
def define_message_handler(
component_type: str, keys: list[str], schemas: dict[str, TSchema]
) -> None:
# The macros defined here should be able to generate things like this:
# // Parsing a message and publishing to sensors
# case MessageId::Message:
# // Can have multiple sensors here, for example for a Status message with multiple flags
# this->thing_binary_sensor->publish_state(parse_flag8_lb_0(response));
# this->other_binary_sensor->publish_state(parse_flag8_lb_1(response));
# break;
# // Building a message for a write request
# case MessageId::Message: {
# unsigned int data = 0;
# data = write_flag8_lb_0(some_input_switch->state, data); // Where input_sensor can also be a number/output/switch
# data = write_u8_hb(some_number->state, data);
# return opentherm_->build_request_(MessageType::WriteData, MessageId::Message, data);
# }
messages: dict[str, list[tuple[str, str]]] = {}
for key in keys:
msg = schemas[key].message
if msg not in messages:
messages[msg] = []
messages[msg].append((key, schemas[key].message_data))
cg.add_define(
f"OPENTHERM_{component_type.upper()}_MESSAGE_HANDLERS(MESSAGE, ENTITY, entity_sep, postscript, msg_sep)",
cg.RawExpression(
" msg_sep ".join(
[
f"MESSAGE({msg}) "
+ " entity_sep ".join(
[
f"ENTITY({key}_{component_type.lower()}, {msg_data})"
for key, msg_data in keys
]
)
+ " postscript"
for msg, keys in messages.items()
]
)
),
)
def define_readers(component_type: str, keys: list[str]) -> None:
for key in keys:
cg.add_define(
f"OPENTHERM_READ_{key}",
cg.RawExpression(f"this->{key}_{component_type.lower()}->state"),
)
def add_messages(hub: cg.MockObj, keys: list[str], schemas: dict[str, TSchema]):
messages: set[tuple[str, bool]] = set()
for key in keys:
messages.add((schemas[key].message, schemas[key].keep_updated))
for msg, keep_updated in messages:
msg_expr = cg.RawExpression(f"esphome::opentherm::MessageId::{msg}")
if keep_updated:
cg.add(hub.add_repeating_message(msg_expr))
else:
cg.add(hub.add_initial_message(msg_expr))
def add_property_set(var: cg.MockObj, config_key: str, config: dict[str, Any]) -> None:
if config_key in config:
cg.add(getattr(var, f"set_{config_key}")(config[config_key]))
Create = Callable[[dict[str, Any], str, cg.MockObj], Awaitable[cg.Pvariable]]
def create_only_conf(
create: Callable[[dict[str, Any]], Awaitable[cg.Pvariable]]
) -> Create:
return lambda conf, _key, _hub: create(conf)
async def component_to_code(
component_type: str,
schemas: dict[str, TSchema],
type: cg.MockObjClass,
create: Create,
config: dict[str, Any],
) -> list[str]:
"""Generate the code for each configured component in the schema of a component type.
Parameters:
- component_type: The type of component, e.g. "sensor" or "binary_sensor"
- schema_: The schema for that component type, a list of available components
- type: The type of the component, e.g. sensor.Sensor or OpenthermOutput
- create: A constructor function for the component, which receives the config,
the key and the hub and should asynchronously return the new component
- config: The configuration for this component type
Returns: The list of keys for the created components
"""
cg.add_define(f"OPENTHERM_USE_{component_type.upper()}")
hub = await cg.get_variable(config[const.CONF_OPENTHERM_ID])
keys: list[str] = []
for key, conf in config.items():
if not isinstance(conf, dict):
continue
id = conf[CONF_ID]
if id and id.type == type:
entity = await create(conf, key, hub)
cg.add(getattr(hub, f"set_{key}_{component_type.lower()}")(entity))
keys.append(key)
define_has_component(component_type, keys)
define_message_handler(component_type, keys, schemas)
add_messages(hub, keys, schemas)
return keys

View File

@ -7,50 +7,114 @@ namespace esphome {
namespace opentherm {
static const char *const TAG = "opentherm";
namespace message_data {
bool parse_flag8_lb_0(OpenthermData &data) { return read_bit(data.valueLB, 0); }
bool parse_flag8_lb_1(OpenthermData &data) { return read_bit(data.valueLB, 1); }
bool parse_flag8_lb_2(OpenthermData &data) { return read_bit(data.valueLB, 2); }
bool parse_flag8_lb_3(OpenthermData &data) { return read_bit(data.valueLB, 3); }
bool parse_flag8_lb_4(OpenthermData &data) { return read_bit(data.valueLB, 4); }
bool parse_flag8_lb_5(OpenthermData &data) { return read_bit(data.valueLB, 5); }
bool parse_flag8_lb_6(OpenthermData &data) { return read_bit(data.valueLB, 6); }
bool parse_flag8_lb_7(OpenthermData &data) { return read_bit(data.valueLB, 7); }
bool parse_flag8_hb_0(OpenthermData &data) { return read_bit(data.valueHB, 0); }
bool parse_flag8_hb_1(OpenthermData &data) { return read_bit(data.valueHB, 1); }
bool parse_flag8_hb_2(OpenthermData &data) { return read_bit(data.valueHB, 2); }
bool parse_flag8_hb_3(OpenthermData &data) { return read_bit(data.valueHB, 3); }
bool parse_flag8_hb_4(OpenthermData &data) { return read_bit(data.valueHB, 4); }
bool parse_flag8_hb_5(OpenthermData &data) { return read_bit(data.valueHB, 5); }
bool parse_flag8_hb_6(OpenthermData &data) { return read_bit(data.valueHB, 6); }
bool parse_flag8_hb_7(OpenthermData &data) { return read_bit(data.valueHB, 7); }
uint8_t parse_u8_lb(OpenthermData &data) { return data.valueLB; }
uint8_t parse_u8_hb(OpenthermData &data) { return data.valueHB; }
int8_t parse_s8_lb(OpenthermData &data) { return (int8_t) data.valueLB; }
int8_t parse_s8_hb(OpenthermData &data) { return (int8_t) data.valueHB; }
uint16_t parse_u16(OpenthermData &data) { return data.u16(); }
int16_t parse_s16(OpenthermData &data) { return data.s16(); }
float parse_f88(OpenthermData &data) { return data.f88(); }
OpenthermData OpenthermHub::build_request_(MessageId request_id) {
void write_flag8_lb_0(const bool value, OpenthermData &data) { data.valueLB = write_bit(data.valueLB, 0, value); }
void write_flag8_lb_1(const bool value, OpenthermData &data) { data.valueLB = write_bit(data.valueLB, 1, value); }
void write_flag8_lb_2(const bool value, OpenthermData &data) { data.valueLB = write_bit(data.valueLB, 2, value); }
void write_flag8_lb_3(const bool value, OpenthermData &data) { data.valueLB = write_bit(data.valueLB, 3, value); }
void write_flag8_lb_4(const bool value, OpenthermData &data) { data.valueLB = write_bit(data.valueLB, 4, value); }
void write_flag8_lb_5(const bool value, OpenthermData &data) { data.valueLB = write_bit(data.valueLB, 5, value); }
void write_flag8_lb_6(const bool value, OpenthermData &data) { data.valueLB = write_bit(data.valueLB, 6, value); }
void write_flag8_lb_7(const bool value, OpenthermData &data) { data.valueLB = write_bit(data.valueLB, 7, value); }
void write_flag8_hb_0(const bool value, OpenthermData &data) { data.valueHB = write_bit(data.valueHB, 0, value); }
void write_flag8_hb_1(const bool value, OpenthermData &data) { data.valueHB = write_bit(data.valueHB, 1, value); }
void write_flag8_hb_2(const bool value, OpenthermData &data) { data.valueHB = write_bit(data.valueHB, 2, value); }
void write_flag8_hb_3(const bool value, OpenthermData &data) { data.valueHB = write_bit(data.valueHB, 3, value); }
void write_flag8_hb_4(const bool value, OpenthermData &data) { data.valueHB = write_bit(data.valueHB, 4, value); }
void write_flag8_hb_5(const bool value, OpenthermData &data) { data.valueHB = write_bit(data.valueHB, 5, value); }
void write_flag8_hb_6(const bool value, OpenthermData &data) { data.valueHB = write_bit(data.valueHB, 6, value); }
void write_flag8_hb_7(const bool value, OpenthermData &data) { data.valueHB = write_bit(data.valueHB, 7, value); }
void write_u8_lb(const uint8_t value, OpenthermData &data) { data.valueLB = value; }
void write_u8_hb(const uint8_t value, OpenthermData &data) { data.valueHB = value; }
void write_s8_lb(const int8_t value, OpenthermData &data) { data.valueLB = (uint8_t) value; }
void write_s8_hb(const int8_t value, OpenthermData &data) { data.valueHB = (uint8_t) value; }
void write_u16(const uint16_t value, OpenthermData &data) { data.u16(value); }
void write_s16(const int16_t value, OpenthermData &data) { data.s16(value); }
void write_f88(const float value, OpenthermData &data) { data.f88(value); }
} // namespace message_data
OpenthermData OpenthermHub::build_request_(MessageId request_id) const {
OpenthermData data;
data.type = 0;
data.id = 0;
data.valueHB = 0;
data.valueLB = 0;
// First, handle the status request. This requires special logic, because we
// wouldn't want to inadvertently disable domestic hot water, for example.
// It is also included in the macro-generated code below, but that will
// never be executed, because we short-circuit it here.
// We need this special logic for STATUS message because we have two options for specifying boiler modes:
// with static config values in the hub, or with separate switches.
if (request_id == MessageId::STATUS) {
bool const ch_enabled = this->ch_enable;
bool dhw_enabled = this->dhw_enable;
bool cooling_enabled = this->cooling_enable;
bool otc_enabled = this->otc_active;
bool ch2_enabled = this->ch2_active;
// NOLINTBEGIN
bool const ch_enabled = this->ch_enable && OPENTHERM_READ_ch_enable && OPENTHERM_READ_t_set > 0.0;
bool const dhw_enabled = this->dhw_enable && OPENTHERM_READ_dhw_enable;
bool const cooling_enabled =
this->cooling_enable && OPENTHERM_READ_cooling_enable && OPENTHERM_READ_cooling_control > 0.0;
bool const otc_enabled = this->otc_active && OPENTHERM_READ_otc_active;
bool const ch2_enabled = this->ch2_active && OPENTHERM_READ_ch2_active && OPENTHERM_READ_t_set_ch2 > 0.0;
bool const summer_mode_is_active = this->summer_mode_active && OPENTHERM_READ_summer_mode_active;
bool const dhw_blocked = this->dhw_block && OPENTHERM_READ_dhw_block;
// NOLINTEND
data.type = MessageType::READ_DATA;
data.id = MessageId::STATUS;
data.valueHB = ch_enabled | (dhw_enabled << 1) | (cooling_enabled << 2) | (otc_enabled << 3) | (ch2_enabled << 4);
data.valueHB = ch_enabled | (dhw_enabled << 1) | (cooling_enabled << 2) | (otc_enabled << 3) | (ch2_enabled << 4) |
(summer_mode_is_active << 5) | (dhw_blocked << 6);
return data;
}
// Disable incomplete switch statement warnings, because the cases in each
// switch are generated based on the configured sensors and inputs.
#pragma GCC diagnostic push
#pragma GCC diagnostic ignored "-Wswitch"
// TODO: This is a placeholder for an auto-generated switch statement which builds request structure based on
// which sensors are enabled in config.
switch (request_id) { OPENTHERM_SENSOR_MESSAGE_HANDLERS(OPENTHERM_MESSAGE_READ_MESSAGE, OPENTHERM_IGNORE, , , ) }
#pragma GCC diagnostic pop
return data;
}
return OpenthermData();
// And if we get here, a message was requested which somehow wasn't handled.
// This shouldn't happen due to the way the defines are configured, so we
// log an error and just return a 0 message.
ESP_LOGE(TAG, "Tried to create a request with unknown id %d. This should never happen, so please open an issue.",
request_id);
return {};
}
OpenthermHub::OpenthermHub() : Component() {}
OpenthermHub::OpenthermHub() : Component(), in_pin_{}, out_pin_{} {}
void OpenthermHub::process_response(OpenthermData &data) {
ESP_LOGD(TAG, "Received OpenTherm response with id %d (%s)", data.id,
this->opentherm_->message_id_to_str((MessageId) data.id));
ESP_LOGD(TAG, "%s", this->opentherm_->debug_data(data).c_str());
switch (data.id) {
OPENTHERM_SENSOR_MESSAGE_HANDLERS(OPENTHERM_MESSAGE_RESPONSE_MESSAGE, OPENTHERM_MESSAGE_RESPONSE_ENTITY, ,
OPENTHERM_MESSAGE_RESPONSE_POSTSCRIPT, )
}
}
void OpenthermHub::setup() {
@ -254,15 +318,17 @@ void OpenthermHub::handle_timeout_error_() {
this->stop_opentherm_();
}
#define ID(x) x
#define SHOW2(x) #x
#define SHOW(x) SHOW2(x)
void OpenthermHub::dump_config() {
ESP_LOGCONFIG(TAG, "OpenTherm:");
LOG_PIN(" In: ", this->in_pin_);
LOG_PIN(" Out: ", this->out_pin_);
ESP_LOGCONFIG(TAG, " Sync mode: %d", this->sync_mode_);
ESP_LOGCONFIG(TAG, " Sensors: %s", SHOW(OPENTHERM_SENSOR_LIST(ID, )));
ESP_LOGCONFIG(TAG, " Binary sensors: %s", SHOW(OPENTHERM_BINARY_SENSOR_LIST(ID, )));
ESP_LOGCONFIG(TAG, " Switches: %s", SHOW(OPENTHERM_SWITCH_LIST(ID, )));
ESP_LOGCONFIG(TAG, " Input sensors: %s", SHOW(OPENTHERM_INPUT_SENSOR_LIST(ID, )));
ESP_LOGCONFIG(TAG, " Outputs: %s", SHOW(OPENTHERM_OUTPUT_LIST(ID, )));
ESP_LOGCONFIG(TAG, " Numbers: %s", SHOW(OPENTHERM_NUMBER_LIST(ID, )));
ESP_LOGCONFIG(TAG, " Initial requests:");
for (auto type : this->initial_messages_) {
ESP_LOGCONFIG(TAG, " - %d", type);

View File

@ -7,11 +7,17 @@
#include "opentherm.h"
#ifdef OPENTHERM_USE_SENSOR
#include "esphome/components/sensor/sensor.h"
#endif
#include <memory>
#include <unordered_map>
#include <unordered_set>
#include <functional>
#include "opentherm_macros.h"
namespace esphome {
namespace opentherm {
@ -23,6 +29,8 @@ class OpenthermHub : public Component {
// The OpenTherm interface
std::unique_ptr<OpenTherm> opentherm_;
OPENTHERM_SENSOR_LIST(OPENTHERM_DECLARE_SENSOR, )
// The set of initial messages to send on starting communication with the boiler
std::unordered_set<MessageId> initial_messages_;
// and the repeating messages which are sent repeatedly to update various sensors
@ -44,7 +52,7 @@ class OpenthermHub : public Component {
bool sync_mode_ = false;
// Create OpenTherm messages based on the message id
OpenthermData build_request_(MessageId request_id);
OpenthermData build_request_(MessageId request_id) const;
void handle_protocol_write_error_();
void handle_protocol_read_error_();
void handle_timeout_error_();
@ -78,6 +86,8 @@ class OpenthermHub : public Component {
void set_in_pin(InternalGPIOPin *in_pin) { this->in_pin_ = in_pin; }
void set_out_pin(InternalGPIOPin *out_pin) { this->out_pin_ = out_pin; }
OPENTHERM_SENSOR_LIST(OPENTHERM_SET_SENSOR, )
// Add a request to the set of initial requests
void add_initial_message(MessageId message_id) { this->initial_messages_.insert(message_id); }
// Add a request to the set of repeating requests. Note that a large number of repeating
@ -86,9 +96,10 @@ class OpenthermHub : public Component {
// will be processed.
void add_repeating_message(MessageId message_id) { this->repeating_messages_.insert(message_id); }
// There are five status variables, which can either be set as a simple variable,
// There are seven status variables, which can either be set as a simple variable,
// or using a switch. ch_enable and dhw_enable default to true, the others to false.
bool ch_enable = true, dhw_enable = true, cooling_enable = false, otc_active = false, ch2_active = false;
bool ch_enable = true, dhw_enable = true, cooling_enable = false, otc_active = false, ch2_active = false,
summer_mode_active = false, dhw_block = false;
// Setters for the status variables
void set_ch_enable(bool value) { this->ch_enable = value; }
@ -96,6 +107,8 @@ class OpenthermHub : public Component {
void set_cooling_enable(bool value) { this->cooling_enable = value; }
void set_otc_active(bool value) { this->otc_active = value; }
void set_ch2_active(bool value) { this->ch2_active = value; }
void set_summer_mode_active(bool value) { this->summer_mode_active = value; }
void set_dhw_block(bool value) { this->dhw_block = value; }
void set_sync_mode(bool sync_mode) { this->sync_mode_ = sync_mode; }
float get_setup_priority() const override { return setup_priority::HARDWARE; }

View File

@ -283,6 +283,9 @@ bool OpenTherm::init_esp32_timer_() {
.clk_src = TIMER_SRC_CLK_DEFAULT,
#endif
.divider = 80,
#if defined(SOC_TIMER_GROUP_SUPPORT_XTAL) && ESP_IDF_VERSION_MAJOR < 5
.clk_src = TIMER_SRC_CLK_APB
#endif
};
esp_err_t result;

View File

@ -20,7 +20,6 @@
namespace esphome {
namespace opentherm {
// TODO: Account for immutable semantics change in hub.cpp when doing later installments of OpenTherm PR
template<class T> constexpr T read_bit(T value, uint8_t bit) { return (value >> bit) & 0x01; }
template<class T> constexpr T set_bit(T value, uint8_t bit) { return value |= (1UL << bit); }
@ -28,7 +27,7 @@ template<class T> constexpr T set_bit(T value, uint8_t bit) { return value |= (1
template<class T> constexpr T clear_bit(T value, uint8_t bit) { return value &= ~(1UL << bit); }
template<class T> constexpr T write_bit(T value, uint8_t bit, uint8_t bit_value) {
return bit_value ? setBit(value, bit) : clearBit(value, bit);
return bit_value ? set_bit(value, bit) : clear_bit(value, bit);
}
enum OperationMode {

View File

@ -0,0 +1,91 @@
#pragma once
namespace esphome {
namespace opentherm {
// ===== hub.h macros =====
// *_LIST macros will be generated in defines.h if at least one sensor from each platform is used.
// These lists will look like this:
// #define OPENTHERM_BINARY_SENSOR_LIST(F, sep) F(sensor_1) sep F(sensor_2)
// These lists will be used in hub.h to define sensor fields (passing macros like OPENTHERM_DECLARE_SENSOR as F)
// and setters (passing macros like OPENTHERM_SET_SENSOR as F) (see below)
// In order for things not to break, we define empty lists here in case some platforms are not used in config.
#ifndef OPENTHERM_SENSOR_LIST
#define OPENTHERM_SENSOR_LIST(F, sep)
#endif
// Use macros to create fields for every entity specified in the ESPHome configuration
#define OPENTHERM_DECLARE_SENSOR(entity) sensor::Sensor *entity;
// Setter macros
#define OPENTHERM_SET_SENSOR(entity) \
void set_##entity(sensor::Sensor *sensor) { this->entity = sensor; }
// ===== hub.cpp macros =====
// *_MESSAGE_HANDLERS are generated in defines.h and look like this:
// OPENTHERM_NUMBER_MESSAGE_HANDLERS(MESSAGE, ENTITY, entity_sep, postscript, msg_sep) MESSAGE(COOLING_CONTROL)
// ENTITY(cooling_control_number, f88) postscript msg_sep They contain placeholders for message part and entities parts,
// since one message can contain multiple entities. MESSAGE part is substituted with OPENTHERM_MESSAGE_WRITE_MESSAGE,
// OPENTHERM_MESSAGE_READ_MESSAGE or OPENTHERM_MESSAGE_RESPONSE_MESSAGE. ENTITY part is substituted with
// OPENTHERM_MESSAGE_WRITE_ENTITY or OPENTHERM_MESSAGE_RESPONSE_ENTITY. OPENTHERM_IGNORE is used for sensor read
// requests since no data needs to be sent or processed, just the data id.
// In order for things not to break, we define empty lists here in case some platforms are not used in config.
#ifndef OPENTHERM_SENSOR_MESSAGE_HANDLERS
#define OPENTHERM_SENSOR_MESSAGE_HANDLERS(MESSAGE, ENTITY, entity_sep, postscript, msg_sep)
#endif
// Read data request builder
#define OPENTHERM_MESSAGE_READ_MESSAGE(msg) \
case MessageId::msg: \
data.type = MessageType::READ_DATA; \
data.id = request_id; \
return data;
// Data processing builders
#define OPENTHERM_MESSAGE_RESPONSE_MESSAGE(msg) case MessageId::msg:
#define OPENTHERM_MESSAGE_RESPONSE_ENTITY(key, msg_data) this->key->publish_state(message_data::parse_##msg_data(data));
#define OPENTHERM_MESSAGE_RESPONSE_POSTSCRIPT break;
#define OPENTHERM_IGNORE(x, y)
// Default macros for STATUS entities
#ifndef OPENTHERM_READ_ch_enable
#define OPENTHERM_READ_ch_enable true
#endif
#ifndef OPENTHERM_READ_dhw_enable
#define OPENTHERM_READ_dhw_enable true
#endif
#ifndef OPENTHERM_READ_t_set
#define OPENTHERM_READ_t_set 0.0
#endif
#ifndef OPENTHERM_READ_cooling_enable
#define OPENTHERM_READ_cooling_enable false
#endif
#ifndef OPENTHERM_READ_cooling_control
#define OPENTHERM_READ_cooling_control 0.0
#endif
#ifndef OPENTHERM_READ_otc_active
#define OPENTHERM_READ_otc_active false
#endif
#ifndef OPENTHERM_READ_ch2_active
#define OPENTHERM_READ_ch2_active false
#endif
#ifndef OPENTHERM_READ_t_set_ch2
#define OPENTHERM_READ_t_set_ch2 0.0
#endif
#ifndef OPENTHERM_READ_summer_mode_active
#define OPENTHERM_READ_summer_mode_active false
#endif
#ifndef OPENTHERM_READ_dhw_block
#define OPENTHERM_READ_dhw_block false
#endif
// These macros utilize the structure of *_LIST macros in order
#define ID(x) x
#define SHOW_INNER(x) #x
#define SHOW(x) SHOW_INNER(x)
} // namespace opentherm
} // namespace esphome

View File

@ -0,0 +1,438 @@
# This file contains a schema for all supported sensors, binary sensors and
# inputs of the OpenTherm component.
from dataclasses import dataclass
from typing import Optional, TypeVar
from esphome.const import (
UNIT_CELSIUS,
UNIT_EMPTY,
UNIT_KILOWATT,
UNIT_MICROAMP,
UNIT_PERCENT,
UNIT_REVOLUTIONS_PER_MINUTE,
DEVICE_CLASS_CURRENT,
DEVICE_CLASS_EMPTY,
DEVICE_CLASS_PRESSURE,
DEVICE_CLASS_TEMPERATURE,
STATE_CLASS_MEASUREMENT,
STATE_CLASS_NONE,
STATE_CLASS_TOTAL_INCREASING,
)
@dataclass
class EntitySchema:
description: str
"""Description of the item, based on the OpenTherm spec"""
message: str
"""OpenTherm message id used to read or write the value"""
keep_updated: bool
"""Whether the value should be read or write repeatedly (True) or only during
the initialization phase (False)
"""
message_data: str
"""Instructions on how to interpret the data in the message
- flag8_[hb|lb]_[0-7]: data is a byte of single bit flags,
this flag is set in the high (hb) or low byte (lb),
at position 0 to 7
- u8_[hb|lb]: data is an unsigned 8-bit integer,
in the high (hb) or low byte (lb)
- s8_[hb|lb]: data is an signed 8-bit integer,
in the high (hb) or low byte (lb)
- f88: data is a signed fixed point value with
1 sign bit, 7 integer bits, 8 fractional bits
- u16: data is an unsigned 16-bit integer
- s16: data is a signed 16-bit integer
"""
TSchema = TypeVar("TSchema", bound=EntitySchema)
@dataclass
class SensorSchema(EntitySchema):
accuracy_decimals: int
state_class: str
unit_of_measurement: Optional[str] = None
icon: Optional[str] = None
device_class: Optional[str] = None
disabled_by_default: bool = False
SENSORS: dict[str, SensorSchema] = {
"rel_mod_level": SensorSchema(
description="Relative modulation level",
unit_of_measurement=UNIT_PERCENT,
accuracy_decimals=2,
icon="mdi:percent",
state_class=STATE_CLASS_MEASUREMENT,
message="MODULATION_LEVEL",
keep_updated=True,
message_data="f88",
),
"ch_pressure": SensorSchema(
description="Water pressure in CH circuit",
unit_of_measurement="bar",
accuracy_decimals=2,
device_class=DEVICE_CLASS_PRESSURE,
state_class=STATE_CLASS_MEASUREMENT,
message="CH_WATER_PRESSURE",
keep_updated=True,
message_data="f88",
),
"dhw_flow_rate": SensorSchema(
description="Water flow rate in DHW circuit",
unit_of_measurement="l/min",
accuracy_decimals=2,
icon="mdi:waves-arrow-right",
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_FLOW_RATE",
keep_updated=True,
message_data="f88",
),
"t_boiler": SensorSchema(
description="Boiler water temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="FEED_TEMP",
keep_updated=True,
message_data="f88",
),
"t_dhw": SensorSchema(
description="DHW temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_TEMP",
keep_updated=True,
message_data="f88",
),
"t_outside": SensorSchema(
description="Outside temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="OUTSIDE_TEMP",
keep_updated=True,
message_data="f88",
),
"t_ret": SensorSchema(
description="Return water temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="RETURN_WATER_TEMP",
keep_updated=True,
message_data="f88",
),
"t_storage": SensorSchema(
description="Solar storage temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="SOLAR_STORE_TEMP",
keep_updated=True,
message_data="f88",
),
"t_collector": SensorSchema(
description="Solar collector temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="SOLAR_COLLECT_TEMP",
keep_updated=True,
message_data="s16",
),
"t_flow_ch2": SensorSchema(
description="Flow water temperature CH2 circuit",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="FEED_TEMP_CH2",
keep_updated=True,
message_data="f88",
),
"t_dhw2": SensorSchema(
description="Domestic hot water temperature 2",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW2_TEMP",
keep_updated=True,
message_data="f88",
),
"t_exhaust": SensorSchema(
description="Boiler exhaust temperature",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="EXHAUST_TEMP",
keep_updated=True,
message_data="s16",
),
"fan_speed": SensorSchema(
description="Boiler fan speed",
unit_of_measurement=UNIT_REVOLUTIONS_PER_MINUTE,
accuracy_decimals=0,
device_class=DEVICE_CLASS_EMPTY,
state_class=STATE_CLASS_MEASUREMENT,
message="FAN_SPEED",
keep_updated=True,
message_data="u16",
),
"flame_current": SensorSchema(
description="Boiler flame current",
unit_of_measurement=UNIT_MICROAMP,
accuracy_decimals=0,
device_class=DEVICE_CLASS_CURRENT,
state_class=STATE_CLASS_MEASUREMENT,
message="FLAME_CURRENT",
keep_updated=True,
message_data="f88",
),
"burner_starts": SensorSchema(
description="Number of starts burner",
accuracy_decimals=0,
icon="mdi:gas-burner",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="BURNER_STARTS",
keep_updated=True,
message_data="u16",
),
"ch_pump_starts": SensorSchema(
description="Number of starts CH pump",
accuracy_decimals=0,
icon="mdi:pump",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="CH_PUMP_STARTS",
keep_updated=True,
message_data="u16",
),
"dhw_pump_valve_starts": SensorSchema(
description="Number of starts DHW pump/valve",
accuracy_decimals=0,
icon="mdi:water-pump",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_PUMP_STARTS",
keep_updated=True,
message_data="u16",
),
"dhw_burner_starts": SensorSchema(
description="Number of starts burner during DHW mode",
accuracy_decimals=0,
icon="mdi:gas-burner",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_BURNER_STARTS",
keep_updated=True,
message_data="u16",
),
"burner_operation_hours": SensorSchema(
description="Number of hours that burner is in operation",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="BURNER_HOURS",
keep_updated=True,
message_data="u16",
),
"ch_pump_operation_hours": SensorSchema(
description="Number of hours that CH pump has been running",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="CH_PUMP_HOURS",
keep_updated=True,
message_data="u16",
),
"dhw_pump_valve_operation_hours": SensorSchema(
description="Number of hours that DHW pump has been running or DHW valve has been opened",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_PUMP_HOURS",
keep_updated=True,
message_data="u16",
),
"dhw_burner_operation_hours": SensorSchema(
description="Number of hours that burner is in operation during DHW mode",
accuracy_decimals=0,
icon="mdi:clock-outline",
state_class=STATE_CLASS_TOTAL_INCREASING,
message="DHW_BURNER_HOURS",
keep_updated=True,
message_data="u16",
),
"t_dhw_set_ub": SensorSchema(
description="Upper bound for adjustment of DHW setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_BOUNDS",
keep_updated=False,
message_data="s8_hb",
),
"t_dhw_set_lb": SensorSchema(
description="Lower bound for adjustment of DHW setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_BOUNDS",
keep_updated=False,
message_data="s8_lb",
),
"max_t_set_ub": SensorSchema(
description="Upper bound for adjustment of max CH setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="CH_BOUNDS",
keep_updated=False,
message_data="s8_hb",
),
"max_t_set_lb": SensorSchema(
description="Lower bound for adjustment of max CH setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=0,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="CH_BOUNDS",
keep_updated=False,
message_data="s8_lb",
),
"t_dhw_set": SensorSchema(
description="Domestic hot water temperature setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="DHW_SETPOINT",
keep_updated=True,
message_data="f88",
),
"max_t_set": SensorSchema(
description="Maximum allowable CH water setpoint",
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
message="MAX_CH_SETPOINT",
keep_updated=True,
message_data="f88",
),
"oem_fault_code": SensorSchema(
description="OEM fault code",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
message="FAULT_FLAGS",
keep_updated=True,
message_data="u8_lb",
),
"oem_diagnostic_code": SensorSchema(
description="OEM diagnostic code",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
message="OEM_DIAGNOSTIC",
keep_updated=True,
message_data="u16",
),
"max_capacity": SensorSchema(
description="Maximum boiler capacity (KW)",
unit_of_measurement=UNIT_KILOWATT,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
disabled_by_default=True,
message="MAX_BOILER_CAPACITY",
keep_updated=False,
message_data="u8_hb",
),
"min_mod_level": SensorSchema(
description="Minimum modulation level",
unit_of_measurement=UNIT_PERCENT,
accuracy_decimals=0,
icon="mdi:percent",
disabled_by_default=True,
state_class=STATE_CLASS_MEASUREMENT,
message="MAX_BOILER_CAPACITY",
keep_updated=False,
message_data="u8_lb",
),
"opentherm_version_device": SensorSchema(
description="Version of OpenTherm implemented by device",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="OT_VERSION_DEVICE",
keep_updated=False,
message_data="f88",
),
"device_type": SensorSchema(
description="Device product type",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="VERSION_DEVICE",
keep_updated=False,
message_data="u8_hb",
),
"device_version": SensorSchema(
description="Device product version",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="VERSION_DEVICE",
keep_updated=False,
message_data="u8_lb",
),
"device_id": SensorSchema(
description="Device ID code",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="DEVICE_CONFIG",
keep_updated=False,
message_data="u8_lb",
),
"otc_hc_ratio_ub": SensorSchema(
description="OTC heat curve ratio upper bound",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="OTC_CURVE_BOUNDS",
keep_updated=False,
message_data="u8_hb",
),
"otc_hc_ratio_lb": SensorSchema(
description="OTC heat curve ratio lower bound",
unit_of_measurement=UNIT_EMPTY,
accuracy_decimals=0,
state_class=STATE_CLASS_NONE,
disabled_by_default=True,
message="OTC_CURVE_BOUNDS",
keep_updated=False,
message_data="u8_lb",
),
}

View File

@ -0,0 +1,35 @@
from typing import Any
import esphome.config_validation as cv
from esphome.components import sensor
from .. import const, schema, validate, generate
DEPENDENCIES = [const.OPENTHERM]
COMPONENT_TYPE = const.SENSOR
def get_entity_validation_schema(entity: schema.SensorSchema) -> cv.Schema:
return sensor.sensor_schema(
unit_of_measurement=entity.unit_of_measurement
or sensor._UNDEF, # pylint: disable=protected-access
accuracy_decimals=entity.accuracy_decimals,
device_class=entity.device_class
or sensor._UNDEF, # pylint: disable=protected-access
icon=entity.icon or sensor._UNDEF, # pylint: disable=protected-access
state_class=entity.state_class,
)
CONFIG_SCHEMA = validate.create_component_schema(
schema.SENSORS, get_entity_validation_schema
)
async def to_code(config: dict[str, Any]) -> None:
await generate.component_to_code(
COMPONENT_TYPE,
schema.SENSORS,
sensor.Sensor,
generate.create_only_conf(sensor.new_sensor),
config,
)

View File

@ -0,0 +1,31 @@
from typing import Callable
from voluptuous import Schema
import esphome.config_validation as cv
from . import const, schema, generate
from .schema import TSchema
def create_entities_schema(
entities: dict[str, schema.EntitySchema],
get_entity_validation_schema: Callable[[TSchema], cv.Schema],
) -> Schema:
entity_schema = {}
for key, entity in entities.items():
entity_schema[cv.Optional(key)] = get_entity_validation_schema(entity)
return cv.Schema(entity_schema)
def create_component_schema(
entities: dict[str, schema.EntitySchema],
get_entity_validation_schema: Callable[[TSchema], cv.Schema],
) -> Schema:
return (
cv.Schema(
{cv.GenerateID(const.CONF_OPENTHERM_ID): cv.use_id(generate.OpenthermHub)}
)
.extend(create_entities_schema(entities, get_entity_validation_schema))
.extend(cv.COMPONENT_SCHEMA)
)

View File

@ -1,3 +1,76 @@
api:
wifi:
ap:
ssid: "Thermostat"
password: "MySecretThemostat"
opentherm:
in_pin: 1
out_pin: 2
in_pin: 4
out_pin: 5
ch_enable: true
dhw_enable: false
cooling_enable: false
otc_active: false
ch2_active: true
summer_mode_active: true
dhw_block: true
sync_mode: true
sensor:
- platform: opentherm
rel_mod_level:
name: "Boiler Relative modulation level"
ch_pressure:
name: "Boiler Water pressure in CH circuit"
dhw_flow_rate:
name: "Boiler Water flow rate in DHW circuit"
t_boiler:
name: "Boiler water temperature"
t_dhw:
name: "Boiler DHW temperature"
t_outside:
name: "Boiler Outside temperature"
t_ret:
name: "Boiler Return water temperature"
t_storage:
name: "Boiler Solar storage temperature"
t_collector:
name: "Boiler Solar collector temperature"
t_flow_ch2:
name: "Boiler Flow water temperature CH2 circuit"
t_dhw2:
name: "Boiler Domestic hot water temperature 2"
t_exhaust:
name: "Boiler Exhaust temperature"
burner_starts:
name: "Boiler Number of starts burner"
ch_pump_starts:
name: "Boiler Number of starts CH pump"
dhw_pump_valve_starts:
name: "Boiler Number of starts DHW pump/valve"
dhw_burner_starts:
name: "Boiler Number of starts burner during DHW mode"
burner_operation_hours:
name: "Boiler Number of hours that burner is in operation (i.e. flame on)"
ch_pump_operation_hours:
name: "Boiler Number of hours that CH pump has been running"
dhw_pump_valve_operation_hours:
name: "Boiler Number of hours that DHW pump has been running or DHW valve has been opened"
dhw_burner_operation_hours:
name: "Boiler Number of hours that burner is in operation during DHW mode"
t_dhw_set_ub:
name: "Boiler Upper bound for adjustement of DHW setpoint"
t_dhw_set_lb:
name: "Boiler Lower bound for adjustement of DHW setpoint"
max_t_set_ub:
name: "Boiler Upper bound for adjustement of max CH setpoint"
max_t_set_lb:
name: "Boiler Lower bound for adjustement of max CH setpoint"
t_dhw_set:
name: "Boiler Domestic hot water temperature setpoint"
max_t_set:
name: "Boiler Maximum allowable CH water setpoint"
otc_hc_ratio_ub:
name: "OTC heat curve ratio upper bound"
otc_hc_ratio_lb:
name: "OTC heat curve ratio lower bound"