mirror of
https://github.com/esphome/esphome.git
synced 2024-11-24 12:06:26 +01:00
Clearify channel range
This commit is contained in:
parent
c9bb6e0bc0
commit
6edeb83c18
@ -20,8 +20,8 @@ from esphome.const import (
|
||||
UNIT_WATT,
|
||||
)
|
||||
|
||||
# 10 sensors in range 1-11
|
||||
SENSOR_RANGE = range(1, 12)
|
||||
# 11 sensors in range 1-11
|
||||
CHANNEL_RANGE = range(1, 12)
|
||||
|
||||
DEPENDENCIES = ["spi"]
|
||||
|
||||
@ -35,7 +35,7 @@ VOLTAGE_CB = {
|
||||
device_class=DEVICE_CLASS_VOLTAGE,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
).extend({cv.Optional("voltage_reference", default=1.0): cv.float_})
|
||||
for i in SENSOR_RANGE
|
||||
for i in CHANNEL_RANGE
|
||||
}
|
||||
|
||||
CURRENT_CV = {
|
||||
@ -45,7 +45,7 @@ CURRENT_CV = {
|
||||
device_class=DEVICE_CLASS_CURRENT,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
).extend({cv.Optional("current_reference", default=1.0): cv.float_})
|
||||
for i in SENSOR_RANGE
|
||||
for i in CHANNEL_RANGE
|
||||
}
|
||||
|
||||
ACTIVE_POWER_CV = {
|
||||
@ -55,7 +55,7 @@ ACTIVE_POWER_CV = {
|
||||
device_class=DEVICE_CLASS_POWER,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
).extend({cv.Optional("power_reference", default=1.0): cv.float_})
|
||||
for i in SENSOR_RANGE
|
||||
for i in CHANNEL_RANGE
|
||||
}
|
||||
|
||||
ENERGY_CV = {
|
||||
@ -65,7 +65,7 @@ ENERGY_CV = {
|
||||
device_class=DEVICE_CLASS_ENERGY,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
).extend({cv.Optional("energy_reference", default=1.0): cv.float_})
|
||||
for i in SENSOR_RANGE
|
||||
for i in CHANNEL_RANGE
|
||||
}
|
||||
|
||||
POWER_FACTOR_CV = {
|
||||
@ -75,7 +75,7 @@ POWER_FACTOR_CV = {
|
||||
device_class=DEVICE_CLASS_POWER_FACTOR,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
)
|
||||
for i in SENSOR_RANGE
|
||||
for i in CHANNEL_RANGE
|
||||
}
|
||||
|
||||
CONFIG_SCHEMA = (
|
||||
@ -117,29 +117,35 @@ async def to_code(config):
|
||||
sens = await sensor.new_sensor(temperature_config)
|
||||
cg.add(var.set_temperature_sensor(sens))
|
||||
|
||||
for i in SENSOR_RANGE:
|
||||
if voltage_config := config.get(f"voltage_{i}"):
|
||||
for channel in CHANNEL_RANGE:
|
||||
if voltage_config := config.get(f"voltage_{channel}"):
|
||||
sens = await sensor.new_sensor(voltage_config)
|
||||
cg.add(
|
||||
var.set_voltage_sensor(sens, i, voltage_config.get("voltage_reference"))
|
||||
var.set_voltage_sensor(
|
||||
sens, channel, voltage_config.get("voltage_reference")
|
||||
)
|
||||
if current_config := config.get(f"current_{i}"):
|
||||
)
|
||||
if current_config := config.get(f"current_{channel}"):
|
||||
sens = await sensor.new_sensor(current_config)
|
||||
cg.add(
|
||||
var.set_current_sensor(sens, i, current_config.get("current_reference"))
|
||||
var.set_current_sensor(
|
||||
sens, channel, current_config.get("current_reference")
|
||||
)
|
||||
if active_power_config := config.get(f"active_power_{i}"):
|
||||
)
|
||||
if active_power_config := config.get(f"active_power_{channel}"):
|
||||
sens = await sensor.new_sensor(active_power_config)
|
||||
cg.add(
|
||||
var.set_power_sensor(
|
||||
sens, i, active_power_config.get("power_reference")
|
||||
sens, channel, active_power_config.get("power_reference")
|
||||
)
|
||||
)
|
||||
if energy_config := config.get(f"energy_{i}"):
|
||||
if energy_config := config.get(f"energy_{channel}"):
|
||||
sens = await sensor.new_sensor(energy_config)
|
||||
cg.add(
|
||||
var.set_energy_sensor(sens, i, energy_config.get("energy_reference"))
|
||||
var.set_energy_sensor(
|
||||
sens, channel, energy_config.get("energy_reference")
|
||||
)
|
||||
if power_factor_config := config.get(f"power_factor_{i}"):
|
||||
)
|
||||
if power_factor_config := config.get(f"power_factor_{channel}"):
|
||||
sens = await sensor.new_sensor(power_factor_config)
|
||||
cg.add(var.set_power_factor_sensor(sens, i))
|
||||
cg.add(var.set_power_factor_sensor(sens, channel))
|
||||
|
Loading…
Reference in New Issue
Block a user