pylontech: fix voltage_low and voltage_high wrong unit (#6060)

Co-authored-by: だから <82636574+Dackara@users.noreply.github.com>
This commit is contained in:
functionpointer 2024-01-09 00:30:37 +01:00 committed by GitHub
parent 696bfe6a87
commit 9bdb9dc1a3
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 6 additions and 6 deletions

View File

@ -59,14 +59,14 @@ TYPES: dict[str, cv.Schema] = {
device_class=DEVICE_CLASS_TEMPERATURE,
),
CONF_VOLTAGE_LOW: sensor.sensor_schema(
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=1,
device_class=DEVICE_CLASS_TEMPERATURE,
unit_of_measurement=UNIT_VOLT,
accuracy_decimals=3,
device_class=DEVICE_CLASS_VOLTAGE,
),
CONF_VOLTAGE_HIGH: sensor.sensor_schema(
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=1,
device_class=DEVICE_CLASS_TEMPERATURE,
unit_of_measurement=UNIT_VOLT,
accuracy_decimals=3,
device_class=DEVICE_CLASS_VOLTAGE,
),
CONF_COULOMB: sensor.sensor_schema(
unit_of_measurement=UNIT_PERCENT,