mirror of
https://github.com/esphome/esphome.git
synced 2024-11-13 10:25:03 +01:00
Haier component update to support more protocol variations (#7040)
Co-authored-by: Pavlo Dudnytskyi <pdudnytskyi@astrata.eu>
This commit is contained in:
parent
dd1e480142
commit
ddaa84683b
@ -38,6 +38,9 @@ PROTOCOL_MAX_TEMPERATURE = 30.0
|
||||
PROTOCOL_TARGET_TEMPERATURE_STEP = 1.0
|
||||
PROTOCOL_CURRENT_TEMPERATURE_STEP = 0.5
|
||||
PROTOCOL_CONTROL_PACKET_SIZE = 10
|
||||
PROTOCOL_MIN_SENSORS_PACKET_SIZE = 18
|
||||
PROTOCOL_DEFAULT_SENSORS_PACKET_SIZE = 22
|
||||
PROTOCOL_STATUS_MESSAGE_HEADER_SIZE = 0
|
||||
|
||||
CODEOWNERS = ["@paveldn"]
|
||||
DEPENDENCIES = ["climate", "uart"]
|
||||
@ -48,6 +51,9 @@ CONF_CONTROL_PACKET_SIZE = "control_packet_size"
|
||||
CONF_HORIZONTAL_AIRFLOW = "horizontal_airflow"
|
||||
CONF_ON_ALARM_START = "on_alarm_start"
|
||||
CONF_ON_ALARM_END = "on_alarm_end"
|
||||
CONF_ON_STATUS_MESSAGE = "on_status_message"
|
||||
CONF_SENSORS_PACKET_SIZE = "sensors_packet_size"
|
||||
CONF_STATUS_MESSAGE_HEADER_SIZE = "status_message_header_size"
|
||||
CONF_VERTICAL_AIRFLOW = "vertical_airflow"
|
||||
CONF_WIFI_SIGNAL = "wifi_signal"
|
||||
|
||||
@ -129,6 +135,11 @@ HaierAlarmEndTrigger = haier_ns.class_(
|
||||
automation.Trigger.template(cg.uint8, cg.const_char_ptr),
|
||||
)
|
||||
|
||||
StatusMessageTrigger = haier_ns.class_(
|
||||
"StatusMessageTrigger",
|
||||
automation.Trigger.template(cg.const_char_ptr, cg.size_t),
|
||||
)
|
||||
|
||||
|
||||
def validate_visual(config):
|
||||
if CONF_VISUAL in config:
|
||||
@ -193,6 +204,11 @@ BASE_CONFIG_SCHEMA = (
|
||||
cv.Optional(
|
||||
CONF_ANSWER_TIMEOUT,
|
||||
): cv.positive_time_period_milliseconds,
|
||||
cv.Optional(CONF_ON_STATUS_MESSAGE): automation.validate_automation(
|
||||
{
|
||||
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(StatusMessageTrigger),
|
||||
}
|
||||
),
|
||||
}
|
||||
)
|
||||
.extend(uart.UART_DEVICE_SCHEMA)
|
||||
@ -228,6 +244,14 @@ CONFIG_SCHEMA = cv.All(
|
||||
cv.Optional(
|
||||
CONF_CONTROL_PACKET_SIZE, default=PROTOCOL_CONTROL_PACKET_SIZE
|
||||
): cv.int_range(min=PROTOCOL_CONTROL_PACKET_SIZE, max=50),
|
||||
cv.Optional(
|
||||
CONF_SENSORS_PACKET_SIZE,
|
||||
default=PROTOCOL_DEFAULT_SENSORS_PACKET_SIZE,
|
||||
): cv.int_range(min=PROTOCOL_MIN_SENSORS_PACKET_SIZE, max=50),
|
||||
cv.Optional(
|
||||
CONF_STATUS_MESSAGE_HEADER_SIZE,
|
||||
default=PROTOCOL_STATUS_MESSAGE_HEADER_SIZE,
|
||||
): cv.int_range(min=PROTOCOL_STATUS_MESSAGE_HEADER_SIZE),
|
||||
cv.Optional(
|
||||
CONF_SUPPORTED_PRESETS,
|
||||
default=["BOOST", "ECO", "SLEEP"], # No AWAY by default
|
||||
@ -468,6 +492,16 @@ async def to_code(config):
|
||||
config[CONF_CONTROL_PACKET_SIZE] - PROTOCOL_CONTROL_PACKET_SIZE
|
||||
)
|
||||
)
|
||||
if CONF_SENSORS_PACKET_SIZE in config:
|
||||
cg.add(
|
||||
var.set_extra_sensors_packet_bytes_size(
|
||||
config[CONF_SENSORS_PACKET_SIZE] - PROTOCOL_MIN_SENSORS_PACKET_SIZE
|
||||
)
|
||||
)
|
||||
if CONF_STATUS_MESSAGE_HEADER_SIZE in config:
|
||||
cg.add(
|
||||
var.set_status_message_header_size(config[CONF_STATUS_MESSAGE_HEADER_SIZE])
|
||||
)
|
||||
for conf in config.get(CONF_ON_ALARM_START, []):
|
||||
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
|
||||
await automation.build_automation(
|
||||
@ -478,5 +512,10 @@ async def to_code(config):
|
||||
await automation.build_automation(
|
||||
trigger, [(cg.uint8, "code"), (cg.const_char_ptr, "message")], conf
|
||||
)
|
||||
for conf in config.get(CONF_ON_STATUS_MESSAGE, []):
|
||||
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
|
||||
await automation.build_automation(
|
||||
trigger, [(cg.const_char_ptr, "data"), (cg.size_t, "data_size")], conf
|
||||
)
|
||||
# https://github.com/paveldn/HaierProtocol
|
||||
cg.add_library("pavlodn/HaierProtocol", "0.9.28")
|
||||
cg.add_library("pavlodn/HaierProtocol", "0.9.31")
|
||||
|
@ -186,6 +186,10 @@ void HaierClimateBase::send_custom_command(const haier_protocol::HaierMessage &m
|
||||
this->action_request_ = PendingAction({ActionRequest::SEND_CUSTOM_COMMAND, message});
|
||||
}
|
||||
|
||||
void HaierClimateBase::add_status_message_callback(std::function<void(const char *, size_t)> &&callback) {
|
||||
this->status_message_callback_.add(std::move(callback));
|
||||
}
|
||||
|
||||
haier_protocol::HandlerError HaierClimateBase::answer_preprocess_(
|
||||
haier_protocol::FrameType request_message_type, haier_protocol::FrameType expected_request_message_type,
|
||||
haier_protocol::FrameType answer_message_type, haier_protocol::FrameType expected_answer_message_type,
|
||||
|
@ -4,6 +4,7 @@
|
||||
#include <set>
|
||||
#include "esphome/components/climate/climate.h"
|
||||
#include "esphome/components/uart/uart.h"
|
||||
#include "esphome/core/automation.h"
|
||||
// HaierProtocol
|
||||
#include <protocol/haier_protocol.h>
|
||||
|
||||
@ -56,6 +57,7 @@ class HaierClimateBase : public esphome::Component,
|
||||
void set_answer_timeout(uint32_t timeout);
|
||||
void set_send_wifi(bool send_wifi);
|
||||
void send_custom_command(const haier_protocol::HaierMessage &message);
|
||||
void add_status_message_callback(std::function<void(const char *, size_t)> &&callback);
|
||||
|
||||
protected:
|
||||
enum class ProtocolPhases {
|
||||
@ -140,11 +142,19 @@ class HaierClimateBase : public esphome::Component,
|
||||
esphome::climate::ClimateTraits traits_;
|
||||
HvacSettings current_hvac_settings_;
|
||||
HvacSettings next_hvac_settings_;
|
||||
std::unique_ptr<uint8_t[]> last_status_message_;
|
||||
std::unique_ptr<uint8_t[]> last_status_message_{nullptr};
|
||||
std::chrono::steady_clock::time_point last_request_timestamp_; // For interval between messages
|
||||
std::chrono::steady_clock::time_point last_valid_status_timestamp_; // For protocol timeout
|
||||
std::chrono::steady_clock::time_point last_status_request_; // To request AC status
|
||||
std::chrono::steady_clock::time_point last_signal_request_; // To send WiFI signal level
|
||||
CallbackManager<void(const char *, size_t)> status_message_callback_{};
|
||||
};
|
||||
|
||||
class StatusMessageTrigger : public Trigger<const char *, size_t> {
|
||||
public:
|
||||
explicit StatusMessageTrigger(HaierClimateBase *parent) {
|
||||
parent->add_status_message_callback([this](const char *data, size_t data_size) { this->trigger(data, data_size); });
|
||||
}
|
||||
};
|
||||
|
||||
} // namespace haier
|
||||
|
@ -18,12 +18,13 @@ constexpr int PROTOCOL_OUTDOOR_TEMPERATURE_OFFSET = -64;
|
||||
constexpr uint8_t CONTROL_MESSAGE_RETRIES = 5;
|
||||
constexpr std::chrono::milliseconds CONTROL_MESSAGE_RETRIES_INTERVAL = std::chrono::milliseconds(500);
|
||||
constexpr size_t ALARM_STATUS_REQUEST_INTERVAL_MS = 600000;
|
||||
const uint8_t ONE_BUF[] = {0x00, 0x01};
|
||||
const uint8_t ZERO_BUF[] = {0x00, 0x00};
|
||||
|
||||
HonClimate::HonClimate()
|
||||
: cleaning_status_(CleaningState::NO_CLEANING), got_valid_outdoor_temp_(false), active_alarms_{0x00, 0x00, 0x00,
|
||||
0x00, 0x00, 0x00,
|
||||
0x00, 0x00} {
|
||||
last_status_message_ = std::unique_ptr<uint8_t[]>(new uint8_t[sizeof(hon_protocol::HaierPacketControl)]);
|
||||
this->fan_mode_speed_ = (uint8_t) hon_protocol::FanMode::FAN_MID;
|
||||
this->other_modes_fan_speed_ = (uint8_t) hon_protocol::FanMode::FAN_AUTO;
|
||||
}
|
||||
@ -169,11 +170,18 @@ haier_protocol::HandlerError HonClimate::status_handler_(haier_protocol::FrameTy
|
||||
this->action_request_.reset();
|
||||
this->force_send_control_ = false;
|
||||
} else {
|
||||
if (data_size >= sizeof(hon_protocol::HaierPacketControl) + 2) {
|
||||
memcpy(this->last_status_message_.get(), data + 2, sizeof(hon_protocol::HaierPacketControl));
|
||||
if (!this->last_status_message_) {
|
||||
this->real_control_packet_size_ = sizeof(hon_protocol::HaierPacketControl) + this->extra_control_packet_bytes_;
|
||||
this->real_sensors_packet_size_ = sizeof(hon_protocol::HaierPacketSensors) + this->extra_sensors_packet_bytes_;
|
||||
this->last_status_message_.reset();
|
||||
this->last_status_message_ = std::unique_ptr<uint8_t[]>(new uint8_t[this->real_control_packet_size_]);
|
||||
};
|
||||
if (data_size >= this->real_control_packet_size_ + 2) {
|
||||
memcpy(this->last_status_message_.get(), data + 2 + this->status_message_header_size_,
|
||||
this->real_control_packet_size_);
|
||||
this->status_message_callback_.call((const char *) data, data_size);
|
||||
} else {
|
||||
ESP_LOGW(TAG, "Status packet too small: %d (should be >= %d)", data_size,
|
||||
sizeof(hon_protocol::HaierPacketControl));
|
||||
ESP_LOGW(TAG, "Status packet too small: %d (should be >= %d)", data_size, this->real_control_packet_size_);
|
||||
}
|
||||
switch (this->protocol_phase_) {
|
||||
case ProtocolPhases::SENDING_FIRST_STATUS_REQUEST:
|
||||
@ -479,8 +487,8 @@ void HonClimate::initialization() {
|
||||
}
|
||||
|
||||
haier_protocol::HaierMessage HonClimate::get_control_message() {
|
||||
uint8_t control_out_buffer[sizeof(hon_protocol::HaierPacketControl)];
|
||||
memcpy(control_out_buffer, this->last_status_message_.get(), sizeof(hon_protocol::HaierPacketControl));
|
||||
uint8_t control_out_buffer[haier_protocol::MAX_FRAME_SIZE];
|
||||
memcpy(control_out_buffer, this->last_status_message_.get(), this->real_control_packet_size_);
|
||||
hon_protocol::HaierPacketControl *out_data = (hon_protocol::HaierPacketControl *) control_out_buffer;
|
||||
control_out_buffer[4] = 0; // This byte should be cleared before setting values
|
||||
bool has_hvac_settings = false;
|
||||
@ -636,7 +644,7 @@ haier_protocol::HaierMessage HonClimate::get_control_message() {
|
||||
out_data->health_mode = this->health_mode_ ? 1 : 0;
|
||||
return haier_protocol::HaierMessage(haier_protocol::FrameType::CONTROL,
|
||||
(uint16_t) hon_protocol::SubcommandsControl::SET_GROUP_PARAMETERS,
|
||||
control_out_buffer, sizeof(hon_protocol::HaierPacketControl));
|
||||
control_out_buffer, this->real_control_packet_size_);
|
||||
}
|
||||
|
||||
void HonClimate::process_alarm_message_(const uint8_t *packet, uint8_t size, bool check_new) {
|
||||
@ -758,15 +766,17 @@ void HonClimate::update_sub_text_sensor_(SubTextSensorType type, const std::stri
|
||||
#endif // USE_TEXT_SENSOR
|
||||
|
||||
haier_protocol::HandlerError HonClimate::process_status_message_(const uint8_t *packet_buffer, uint8_t size) {
|
||||
size_t expected_size = 2 + sizeof(hon_protocol::HaierPacketControl) + sizeof(hon_protocol::HaierPacketSensors) +
|
||||
this->extra_control_packet_bytes_;
|
||||
if (size < expected_size)
|
||||
size_t expected_size =
|
||||
2 + this->status_message_header_size_ + this->real_control_packet_size_ + this->real_sensors_packet_size_;
|
||||
if (size < expected_size) {
|
||||
ESP_LOGW(TAG, "Unexpected message size %d (expexted >= %d)", size, expected_size);
|
||||
return haier_protocol::HandlerError::WRONG_MESSAGE_STRUCTURE;
|
||||
}
|
||||
uint16_t subtype = (((uint16_t) packet_buffer[0]) << 8) + packet_buffer[1];
|
||||
if ((subtype == 0x7D01) && (size >= expected_size + 4 + sizeof(hon_protocol::HaierPacketBigData))) {
|
||||
if ((subtype == 0x7D01) && (size >= expected_size + sizeof(hon_protocol::HaierPacketBigData))) {
|
||||
// Got BigData packet
|
||||
const hon_protocol::HaierPacketBigData *bd_packet =
|
||||
(const hon_protocol::HaierPacketBigData *) (&packet_buffer[expected_size + 4]);
|
||||
(const hon_protocol::HaierPacketBigData *) (&packet_buffer[expected_size]);
|
||||
#ifdef USE_SENSOR
|
||||
this->update_sub_sensor_(SubSensorType::INDOOR_COIL_TEMPERATURE, bd_packet->indoor_coil_temperature / 2.0 - 20);
|
||||
this->update_sub_sensor_(SubSensorType::OUTDOOR_COIL_TEMPERATURE, bd_packet->outdoor_coil_temperature - 64);
|
||||
@ -795,9 +805,9 @@ haier_protocol::HandlerError HonClimate::process_status_message_(const uint8_t *
|
||||
hon_protocol::HaierPacketControl control;
|
||||
hon_protocol::HaierPacketSensors sensors;
|
||||
} packet;
|
||||
memcpy(&packet.control, packet_buffer + 2, sizeof(hon_protocol::HaierPacketControl));
|
||||
memcpy(&packet.sensors,
|
||||
packet_buffer + 2 + sizeof(hon_protocol::HaierPacketControl) + this->extra_control_packet_bytes_,
|
||||
memcpy(&packet.control, packet_buffer + 2 + this->status_message_header_size_,
|
||||
sizeof(hon_protocol::HaierPacketControl));
|
||||
memcpy(&packet.sensors, packet_buffer + 2 + this->status_message_header_size_ + this->real_control_packet_size_,
|
||||
sizeof(hon_protocol::HaierPacketSensors));
|
||||
if (packet.sensors.error_status != 0) {
|
||||
ESP_LOGW(TAG, "HVAC error, code=0x%02X", packet.sensors.error_status);
|
||||
@ -996,8 +1006,6 @@ haier_protocol::HandlerError HonClimate::process_status_message_(const uint8_t *
|
||||
}
|
||||
|
||||
void HonClimate::fill_control_messages_queue_() {
|
||||
static uint8_t one_buf[] = {0x00, 0x01};
|
||||
static uint8_t zero_buf[] = {0x00, 0x00};
|
||||
if (!this->current_hvac_settings_.valid && !this->force_send_control_)
|
||||
return;
|
||||
this->clear_control_messages_queue_();
|
||||
@ -1009,7 +1017,7 @@ void HonClimate::fill_control_messages_queue_() {
|
||||
haier_protocol::HaierMessage(haier_protocol::FrameType::CONTROL,
|
||||
(uint16_t) hon_protocol::SubcommandsControl::SET_SINGLE_PARAMETER +
|
||||
(uint8_t) hon_protocol::DataParameters::BEEPER_STATUS,
|
||||
this->beeper_status_ ? zero_buf : one_buf, 2));
|
||||
this->beeper_status_ ? ZERO_BUF : ONE_BUF, 2));
|
||||
}
|
||||
// Health mode
|
||||
{
|
||||
@ -1017,7 +1025,7 @@ void HonClimate::fill_control_messages_queue_() {
|
||||
haier_protocol::HaierMessage(haier_protocol::FrameType::CONTROL,
|
||||
(uint16_t) hon_protocol::SubcommandsControl::SET_SINGLE_PARAMETER +
|
||||
(uint8_t) hon_protocol::DataParameters::HEALTH_MODE,
|
||||
this->health_mode_ ? one_buf : zero_buf, 2));
|
||||
this->health_mode_ ? ONE_BUF : ZERO_BUF, 2));
|
||||
}
|
||||
// Climate mode
|
||||
bool new_power = this->mode != CLIMATE_MODE_OFF;
|
||||
@ -1092,7 +1100,7 @@ void HonClimate::fill_control_messages_queue_() {
|
||||
haier_protocol::HaierMessage(haier_protocol::FrameType::CONTROL,
|
||||
(uint16_t) hon_protocol::SubcommandsControl::SET_SINGLE_PARAMETER +
|
||||
(uint8_t) hon_protocol::DataParameters::AC_POWER,
|
||||
new_power ? one_buf : zero_buf, 2));
|
||||
new_power ? ONE_BUF : ZERO_BUF, 2));
|
||||
}
|
||||
// CLimate preset
|
||||
{
|
||||
@ -1165,6 +1173,35 @@ void HonClimate::fill_control_messages_queue_() {
|
||||
(uint8_t) hon_protocol::DataParameters::SET_POINT,
|
||||
buffer, 2));
|
||||
}
|
||||
// Vertical swing mode
|
||||
if (climate_control.swing_mode.has_value()) {
|
||||
uint8_t vertical_swing_buf[] = {0x00, (uint8_t) hon_protocol::VerticalSwingMode::AUTO};
|
||||
uint8_t horizontal_swing_buf[] = {0x00, (uint8_t) hon_protocol::HorizontalSwingMode::AUTO};
|
||||
switch (climate_control.swing_mode.value()) {
|
||||
case CLIMATE_SWING_OFF:
|
||||
horizontal_swing_buf[1] = (uint8_t) this->settings_.last_horizontal_swing;
|
||||
vertical_swing_buf[1] = (uint8_t) this->settings_.last_vertiacal_swing;
|
||||
break;
|
||||
case CLIMATE_SWING_VERTICAL:
|
||||
horizontal_swing_buf[1] = (uint8_t) this->settings_.last_horizontal_swing;
|
||||
break;
|
||||
case CLIMATE_SWING_HORIZONTAL:
|
||||
vertical_swing_buf[1] = (uint8_t) this->settings_.last_vertiacal_swing;
|
||||
break;
|
||||
case CLIMATE_SWING_BOTH:
|
||||
break;
|
||||
}
|
||||
this->control_messages_queue_.push(
|
||||
haier_protocol::HaierMessage(haier_protocol::FrameType::CONTROL,
|
||||
(uint16_t) hon_protocol::SubcommandsControl::SET_SINGLE_PARAMETER +
|
||||
(uint8_t) hon_protocol::DataParameters::HORIZONTAL_SWING_MODE,
|
||||
horizontal_swing_buf, 2));
|
||||
this->control_messages_queue_.push(
|
||||
haier_protocol::HaierMessage(haier_protocol::FrameType::CONTROL,
|
||||
(uint16_t) hon_protocol::SubcommandsControl::SET_SINGLE_PARAMETER +
|
||||
(uint8_t) hon_protocol::DataParameters::VERTICAL_SWING_MODE,
|
||||
vertical_swing_buf, 2));
|
||||
}
|
||||
// Fan mode
|
||||
if (climate_control.fan_mode.has_value()) {
|
||||
switch (climate_control.fan_mode.value()) {
|
||||
@ -1202,40 +1239,56 @@ void HonClimate::clear_control_messages_queue_() {
|
||||
|
||||
bool HonClimate::prepare_pending_action() {
|
||||
switch (this->action_request_.value().action) {
|
||||
case ActionRequest::START_SELF_CLEAN: {
|
||||
uint8_t control_out_buffer[sizeof(hon_protocol::HaierPacketControl)];
|
||||
memcpy(control_out_buffer, this->last_status_message_.get(), sizeof(hon_protocol::HaierPacketControl));
|
||||
hon_protocol::HaierPacketControl *out_data = (hon_protocol::HaierPacketControl *) control_out_buffer;
|
||||
out_data->self_cleaning_status = 1;
|
||||
out_data->steri_clean = 0;
|
||||
out_data->set_point = 0x06;
|
||||
out_data->vertical_swing_mode = (uint8_t) hon_protocol::VerticalSwingMode::CENTER;
|
||||
out_data->horizontal_swing_mode = (uint8_t) hon_protocol::HorizontalSwingMode::CENTER;
|
||||
out_data->ac_power = 1;
|
||||
out_data->ac_mode = (uint8_t) hon_protocol::ConditioningMode::DRY;
|
||||
out_data->light_status = 0;
|
||||
this->action_request_.value().message = haier_protocol::HaierMessage(
|
||||
haier_protocol::FrameType::CONTROL, (uint16_t) hon_protocol::SubcommandsControl::SET_GROUP_PARAMETERS,
|
||||
control_out_buffer, sizeof(hon_protocol::HaierPacketControl));
|
||||
}
|
||||
return true;
|
||||
case ActionRequest::START_STERI_CLEAN: {
|
||||
uint8_t control_out_buffer[sizeof(hon_protocol::HaierPacketControl)];
|
||||
memcpy(control_out_buffer, this->last_status_message_.get(), sizeof(hon_protocol::HaierPacketControl));
|
||||
hon_protocol::HaierPacketControl *out_data = (hon_protocol::HaierPacketControl *) control_out_buffer;
|
||||
out_data->self_cleaning_status = 0;
|
||||
out_data->steri_clean = 1;
|
||||
out_data->set_point = 0x06;
|
||||
out_data->vertical_swing_mode = (uint8_t) hon_protocol::VerticalSwingMode::CENTER;
|
||||
out_data->horizontal_swing_mode = (uint8_t) hon_protocol::HorizontalSwingMode::CENTER;
|
||||
out_data->ac_power = 1;
|
||||
out_data->ac_mode = (uint8_t) hon_protocol::ConditioningMode::DRY;
|
||||
out_data->light_status = 0;
|
||||
this->action_request_.value().message = haier_protocol::HaierMessage(
|
||||
haier_protocol::FrameType::CONTROL, (uint16_t) hon_protocol::SubcommandsControl::SET_GROUP_PARAMETERS,
|
||||
control_out_buffer, sizeof(hon_protocol::HaierPacketControl));
|
||||
}
|
||||
return true;
|
||||
case ActionRequest::START_SELF_CLEAN:
|
||||
if (this->control_method_ == HonControlMethod::SET_GROUP_PARAMETERS) {
|
||||
uint8_t control_out_buffer[haier_protocol::MAX_FRAME_SIZE];
|
||||
memcpy(control_out_buffer, this->last_status_message_.get(), this->real_control_packet_size_);
|
||||
hon_protocol::HaierPacketControl *out_data = (hon_protocol::HaierPacketControl *) control_out_buffer;
|
||||
out_data->self_cleaning_status = 1;
|
||||
out_data->steri_clean = 0;
|
||||
out_data->set_point = 0x06;
|
||||
out_data->vertical_swing_mode = (uint8_t) hon_protocol::VerticalSwingMode::CENTER;
|
||||
out_data->horizontal_swing_mode = (uint8_t) hon_protocol::HorizontalSwingMode::CENTER;
|
||||
out_data->ac_power = 1;
|
||||
out_data->ac_mode = (uint8_t) hon_protocol::ConditioningMode::DRY;
|
||||
out_data->light_status = 0;
|
||||
this->action_request_.value().message = haier_protocol::HaierMessage(
|
||||
haier_protocol::FrameType::CONTROL, (uint16_t) hon_protocol::SubcommandsControl::SET_GROUP_PARAMETERS,
|
||||
control_out_buffer, this->real_control_packet_size_);
|
||||
return true;
|
||||
} else if (this->control_method_ == HonControlMethod::SET_SINGLE_PARAMETER) {
|
||||
this->action_request_.value().message =
|
||||
haier_protocol::HaierMessage(haier_protocol::FrameType::CONTROL,
|
||||
(uint16_t) hon_protocol::SubcommandsControl::SET_SINGLE_PARAMETER +
|
||||
(uint8_t) hon_protocol::DataParameters::SELF_CLEANING,
|
||||
ONE_BUF, 2);
|
||||
return true;
|
||||
} else {
|
||||
this->action_request_.reset();
|
||||
return false;
|
||||
}
|
||||
case ActionRequest::START_STERI_CLEAN:
|
||||
if (this->control_method_ == HonControlMethod::SET_GROUP_PARAMETERS) {
|
||||
uint8_t control_out_buffer[haier_protocol::MAX_FRAME_SIZE];
|
||||
memcpy(control_out_buffer, this->last_status_message_.get(), this->real_control_packet_size_);
|
||||
hon_protocol::HaierPacketControl *out_data = (hon_protocol::HaierPacketControl *) control_out_buffer;
|
||||
out_data->self_cleaning_status = 0;
|
||||
out_data->steri_clean = 1;
|
||||
out_data->set_point = 0x06;
|
||||
out_data->vertical_swing_mode = (uint8_t) hon_protocol::VerticalSwingMode::CENTER;
|
||||
out_data->horizontal_swing_mode = (uint8_t) hon_protocol::HorizontalSwingMode::CENTER;
|
||||
out_data->ac_power = 1;
|
||||
out_data->ac_mode = (uint8_t) hon_protocol::ConditioningMode::DRY;
|
||||
out_data->light_status = 0;
|
||||
this->action_request_.value().message = haier_protocol::HaierMessage(
|
||||
haier_protocol::FrameType::CONTROL, (uint16_t) hon_protocol::SubcommandsControl::SET_GROUP_PARAMETERS,
|
||||
control_out_buffer, this->real_control_packet_size_);
|
||||
return true;
|
||||
} else {
|
||||
// No Steri clean support (yet?) in SET_SINGLE_PARAMETER
|
||||
this->action_request_.reset();
|
||||
return false;
|
||||
}
|
||||
default:
|
||||
return HaierClimateBase::prepare_pending_action();
|
||||
}
|
||||
@ -1251,6 +1304,7 @@ void HonClimate::process_protocol_reset() {
|
||||
#endif // USE_SENSOR
|
||||
this->got_valid_outdoor_temp_ = false;
|
||||
this->hvac_hardware_info_.reset();
|
||||
this->last_status_message_.reset(nullptr);
|
||||
}
|
||||
|
||||
bool HonClimate::should_get_big_data_() {
|
||||
|
@ -104,6 +104,8 @@ class HonClimate : public HaierClimateBase {
|
||||
void start_self_cleaning();
|
||||
void start_steri_cleaning();
|
||||
void set_extra_control_packet_bytes_size(size_t size) { this->extra_control_packet_bytes_ = size; };
|
||||
void set_extra_sensors_packet_bytes_size(size_t size) { this->extra_sensors_packet_bytes_ = size; };
|
||||
void set_status_message_header_size(size_t size) { this->status_message_header_size_ = size; };
|
||||
void set_control_method(HonControlMethod method) { this->control_method_ = method; };
|
||||
void add_alarm_start_callback(std::function<void(uint8_t, const char *)> &&callback);
|
||||
void add_alarm_end_callback(std::function<void(uint8_t, const char *)> &&callback);
|
||||
@ -158,7 +160,11 @@ class HonClimate : public HaierClimateBase {
|
||||
esphome::optional<hon_protocol::HorizontalSwingMode> pending_horizontal_direction_{};
|
||||
esphome::optional<HardwareInfo> hvac_hardware_info_{};
|
||||
uint8_t active_alarms_[8];
|
||||
int extra_control_packet_bytes_;
|
||||
int extra_control_packet_bytes_{0};
|
||||
int extra_sensors_packet_bytes_{4};
|
||||
int status_message_header_size_{0};
|
||||
int real_control_packet_size_{sizeof(hon_protocol::HaierPacketControl)};
|
||||
int real_sensors_packet_size_{sizeof(hon_protocol::HaierPacketSensors) + 4};
|
||||
HonControlMethod control_method_;
|
||||
std::queue<haier_protocol::HaierMessage> control_messages_queue_;
|
||||
CallbackManager<void(uint8_t, const char *)> alarm_start_callback_{};
|
||||
|
@ -41,15 +41,20 @@ enum class ConditioningMode : uint8_t {
|
||||
enum class DataParameters : uint8_t {
|
||||
AC_POWER = 0x01,
|
||||
SET_POINT = 0x02,
|
||||
VERTICAL_SWING_MODE = 0x03,
|
||||
AC_MODE = 0x04,
|
||||
FAN_MODE = 0x05,
|
||||
USE_FAHRENHEIT = 0x07,
|
||||
DISPLAY_STATUS = 0x09,
|
||||
TEN_DEGREE = 0x0A,
|
||||
HEALTH_MODE = 0x0B,
|
||||
HORIZONTAL_SWING_MODE = 0x0C,
|
||||
SELF_CLEANING = 0x0D,
|
||||
BEEPER_STATUS = 0x16,
|
||||
LOCK_REMOTE = 0x17,
|
||||
QUIET_MODE = 0x19,
|
||||
FAST_MODE = 0x1A,
|
||||
SLEEP_MODE = 0x1B,
|
||||
};
|
||||
|
||||
enum class SpecialMode : uint8_t { NONE = 0x00, ELDERLY = 0x01, CHILDREN = 0x02, PREGNANT = 0x03 };
|
||||
|
@ -37,6 +37,7 @@ haier_protocol::HandlerError Smartair2Climate::status_handler_(haier_protocol::F
|
||||
} else {
|
||||
if (data_size >= sizeof(smartair2_protocol::HaierPacketControl) + 2) {
|
||||
memcpy(this->last_status_message_.get(), data + 2, sizeof(smartair2_protocol::HaierPacketControl));
|
||||
this->status_message_callback_.call((const char *) data, data_size);
|
||||
} else {
|
||||
ESP_LOGW(TAG, "Status packet too small: %d (should be >= %d)", data_size,
|
||||
sizeof(smartair2_protocol::HaierPacketControl));
|
||||
|
@ -39,7 +39,7 @@ lib_deps =
|
||||
bblanchon/ArduinoJson@6.18.5 ; json
|
||||
wjtje/qr-code-generator-library@1.7.0 ; qr_code
|
||||
functionpointer/arduino-MLX90393@1.0.0 ; mlx90393
|
||||
pavlodn/HaierProtocol@0.9.28 ; haier
|
||||
pavlodn/HaierProtocol@0.9.31 ; haier
|
||||
; This is using the repository until a new release is published to PlatformIO
|
||||
https://github.com/Sensirion/arduino-gas-index-algorithm.git#3.2.1 ; Sensirion Gas Index Algorithm Arduino Library
|
||||
build_flags =
|
||||
|
114
tests/components/haier/common.yaml
Normal file
114
tests/components/haier/common.yaml
Normal file
@ -0,0 +1,114 @@
|
||||
wifi:
|
||||
ssid: MySSID
|
||||
password: password1
|
||||
|
||||
uart:
|
||||
- id: uart_haier
|
||||
tx_pin: ${tx_pin}
|
||||
rx_pin: ${rx_pin}
|
||||
baud_rate: 9600
|
||||
|
||||
climate:
|
||||
- platform: haier
|
||||
id: haier_ac
|
||||
uart_id: uart_haier
|
||||
protocol: hOn
|
||||
name: Haier AC
|
||||
wifi_signal: true
|
||||
answer_timeout: 200ms
|
||||
beeper: true
|
||||
visual:
|
||||
min_temperature: 16 °C
|
||||
max_temperature: 30 °C
|
||||
temperature_step:
|
||||
target_temperature: 1
|
||||
current_temperature: 0.5
|
||||
supported_modes:
|
||||
- 'OFF'
|
||||
- HEAT_COOL
|
||||
- COOL
|
||||
- HEAT
|
||||
- DRY
|
||||
- FAN_ONLY
|
||||
supported_swing_modes:
|
||||
- 'OFF'
|
||||
- VERTICAL
|
||||
- HORIZONTAL
|
||||
- BOTH
|
||||
supported_presets:
|
||||
- AWAY
|
||||
- BOOST
|
||||
- ECO
|
||||
- SLEEP
|
||||
on_alarm_start:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm activated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
on_alarm_end:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm deactivated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
|
||||
sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
outdoor_temperature:
|
||||
name: Haier outdoor temperature
|
||||
humidity:
|
||||
name: Haier Indoor Humidity
|
||||
compressor_current:
|
||||
name: Haier Compressor Current
|
||||
compressor_frequency:
|
||||
name: Haier Compressor Frequency
|
||||
expansion_valve_open_degree:
|
||||
name: Haier Expansion Valve Open Degree
|
||||
indoor_coil_temperature:
|
||||
name: Haier Indoor Coil Temperature
|
||||
outdoor_coil_temperature:
|
||||
name: Haier Outdoor Coil Temperature
|
||||
outdoor_defrost_temperature:
|
||||
name: Haier Outdoor Defrost Temperature
|
||||
outdoor_in_air_temperature:
|
||||
name: Haier Outdoor In Air Temperature
|
||||
outdoor_out_air_temperature:
|
||||
name: Haier Outdoor Out Air Temperature
|
||||
power:
|
||||
name: Haier Power
|
||||
|
||||
binary_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
compressor_status:
|
||||
name: Haier Outdoor Compressor Status
|
||||
defrost_status:
|
||||
name: Haier Defrost Status
|
||||
four_way_valve_status:
|
||||
name: Haier Four Way Valve Status
|
||||
indoor_electric_heating_status:
|
||||
name: Haier Indoor Electric Heating Status
|
||||
indoor_fan_status:
|
||||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
@ -1,113 +1,5 @@
|
||||
wifi:
|
||||
ssid: MySSID
|
||||
password: password1
|
||||
substitutions:
|
||||
tx_pin: GPIO17
|
||||
rx_pin: GPIO16
|
||||
|
||||
uart:
|
||||
- id: uart_haier
|
||||
tx_pin: 17
|
||||
rx_pin: 16
|
||||
baud_rate: 9600
|
||||
|
||||
climate:
|
||||
- platform: haier
|
||||
id: haier_ac
|
||||
protocol: hOn
|
||||
name: Haier AC
|
||||
wifi_signal: true
|
||||
answer_timeout: 200ms
|
||||
beeper: true
|
||||
visual:
|
||||
min_temperature: 16 °C
|
||||
max_temperature: 30 °C
|
||||
temperature_step:
|
||||
target_temperature: 1
|
||||
current_temperature: 0.5
|
||||
supported_modes:
|
||||
- 'OFF'
|
||||
- HEAT_COOL
|
||||
- COOL
|
||||
- HEAT
|
||||
- DRY
|
||||
- FAN_ONLY
|
||||
supported_swing_modes:
|
||||
- 'OFF'
|
||||
- VERTICAL
|
||||
- HORIZONTAL
|
||||
- BOTH
|
||||
supported_presets:
|
||||
- AWAY
|
||||
- BOOST
|
||||
- ECO
|
||||
- SLEEP
|
||||
on_alarm_start:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm activated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
on_alarm_end:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm deactivated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
|
||||
sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
outdoor_temperature:
|
||||
name: Haier outdoor temperature
|
||||
humidity:
|
||||
name: Haier Indoor Humidity
|
||||
compressor_current:
|
||||
name: Haier Compressor Current
|
||||
compressor_frequency:
|
||||
name: Haier Compressor Frequency
|
||||
expansion_valve_open_degree:
|
||||
name: Haier Expansion Valve Open Degree
|
||||
indoor_coil_temperature:
|
||||
name: Haier Indoor Coil Temperature
|
||||
outdoor_coil_temperature:
|
||||
name: Haier Outdoor Coil Temperature
|
||||
outdoor_defrost_temperature:
|
||||
name: Haier Outdoor Defrost Temperature
|
||||
outdoor_in_air_temperature:
|
||||
name: Haier Outdoor In Air Temperature
|
||||
outdoor_out_air_temperature:
|
||||
name: Haier Outdoor Out Air Temperature
|
||||
power:
|
||||
name: Haier Power
|
||||
|
||||
binary_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
compressor_status:
|
||||
name: Haier Outdoor Compressor Status
|
||||
defrost_status:
|
||||
name: Haier Defrost Status
|
||||
four_way_valve_status:
|
||||
name: Haier Four Way Valve Status
|
||||
indoor_electric_heating_status:
|
||||
name: Haier Indoor Electric Heating Status
|
||||
indoor_fan_status:
|
||||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
<<: !include common.yaml
|
||||
|
@ -1,109 +1,5 @@
|
||||
wifi:
|
||||
ssid: MySSID
|
||||
password: password1
|
||||
substitutions:
|
||||
tx_pin: GPIO4
|
||||
rx_pin: GPIO5
|
||||
|
||||
uart:
|
||||
- id: uart_haier
|
||||
tx_pin: 4
|
||||
rx_pin: 5
|
||||
baud_rate: 9600
|
||||
|
||||
climate:
|
||||
- platform: haier
|
||||
id: haier_ac
|
||||
protocol: hOn
|
||||
name: Haier AC
|
||||
wifi_signal: true
|
||||
answer_timeout: 200ms
|
||||
beeper: true
|
||||
visual:
|
||||
min_temperature: 16 °C
|
||||
max_temperature: 30 °C
|
||||
temperature_step:
|
||||
target_temperature: 1
|
||||
current_temperature: 0.5
|
||||
supported_modes:
|
||||
- 'OFF'
|
||||
- HEAT_COOL
|
||||
- COOL
|
||||
- HEAT
|
||||
- DRY
|
||||
- FAN_ONLY
|
||||
supported_swing_modes:
|
||||
- 'OFF'
|
||||
- VERTICAL
|
||||
- HORIZONTAL
|
||||
- BOTH
|
||||
supported_presets:
|
||||
- AWAY
|
||||
- BOOST
|
||||
- ECO
|
||||
- SLEEP
|
||||
on_alarm_start:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm activated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
on_alarm_end:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm deactivated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
|
||||
sensor:
|
||||
- platform: haier
|
||||
outdoor_temperature:
|
||||
name: Haier outdoor temperature
|
||||
humidity:
|
||||
name: Haier Indoor Humidity
|
||||
compressor_current:
|
||||
name: Haier Compressor Current
|
||||
compressor_frequency:
|
||||
name: Haier Compressor Frequency
|
||||
expansion_valve_open_degree:
|
||||
name: Haier Expansion Valve Open Degree
|
||||
indoor_coil_temperature:
|
||||
name: Haier Indoor Coil Temperature
|
||||
outdoor_coil_temperature:
|
||||
name: Haier Outdoor Coil Temperature
|
||||
outdoor_defrost_temperature:
|
||||
name: Haier Outdoor Defrost Temperature
|
||||
outdoor_in_air_temperature:
|
||||
name: Haier Outdoor In Air Temperature
|
||||
outdoor_out_air_temperature:
|
||||
name: Haier Outdoor Out Air Temperature
|
||||
power:
|
||||
name: Haier Power
|
||||
|
||||
binary_sensor:
|
||||
- platform: haier
|
||||
compressor_status:
|
||||
name: Haier Outdoor Compressor Status
|
||||
defrost_status:
|
||||
name: Haier Defrost Status
|
||||
four_way_valve_status:
|
||||
name: Haier Four Way Valve Status
|
||||
indoor_electric_heating_status:
|
||||
name: Haier Indoor Electric Heating Status
|
||||
indoor_fan_status:
|
||||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
<<: !include common.yaml
|
||||
|
@ -1,109 +1,5 @@
|
||||
wifi:
|
||||
ssid: MySSID
|
||||
password: password1
|
||||
substitutions:
|
||||
tx_pin: GPIO4
|
||||
rx_pin: GPIO5
|
||||
|
||||
uart:
|
||||
- id: uart_haier
|
||||
tx_pin: 4
|
||||
rx_pin: 5
|
||||
baud_rate: 9600
|
||||
|
||||
climate:
|
||||
- platform: haier
|
||||
id: haier_ac
|
||||
protocol: hOn
|
||||
name: Haier AC
|
||||
wifi_signal: true
|
||||
answer_timeout: 200ms
|
||||
beeper: true
|
||||
visual:
|
||||
min_temperature: 16 °C
|
||||
max_temperature: 30 °C
|
||||
temperature_step:
|
||||
target_temperature: 1
|
||||
current_temperature: 0.5
|
||||
supported_modes:
|
||||
- 'OFF'
|
||||
- HEAT_COOL
|
||||
- COOL
|
||||
- HEAT
|
||||
- DRY
|
||||
- FAN_ONLY
|
||||
supported_swing_modes:
|
||||
- 'OFF'
|
||||
- VERTICAL
|
||||
- HORIZONTAL
|
||||
- BOTH
|
||||
supported_presets:
|
||||
- AWAY
|
||||
- BOOST
|
||||
- ECO
|
||||
- SLEEP
|
||||
on_alarm_start:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm activated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
on_alarm_end:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm deactivated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
|
||||
sensor:
|
||||
- platform: haier
|
||||
outdoor_temperature:
|
||||
name: Haier outdoor temperature
|
||||
humidity:
|
||||
name: Haier Indoor Humidity
|
||||
compressor_current:
|
||||
name: Haier Compressor Current
|
||||
compressor_frequency:
|
||||
name: Haier Compressor Frequency
|
||||
expansion_valve_open_degree:
|
||||
name: Haier Expansion Valve Open Degree
|
||||
indoor_coil_temperature:
|
||||
name: Haier Indoor Coil Temperature
|
||||
outdoor_coil_temperature:
|
||||
name: Haier Outdoor Coil Temperature
|
||||
outdoor_defrost_temperature:
|
||||
name: Haier Outdoor Defrost Temperature
|
||||
outdoor_in_air_temperature:
|
||||
name: Haier Outdoor In Air Temperature
|
||||
outdoor_out_air_temperature:
|
||||
name: Haier Outdoor Out Air Temperature
|
||||
power:
|
||||
name: Haier Power
|
||||
|
||||
binary_sensor:
|
||||
- platform: haier
|
||||
compressor_status:
|
||||
name: Haier Outdoor Compressor Status
|
||||
defrost_status:
|
||||
name: Haier Defrost Status
|
||||
four_way_valve_status:
|
||||
name: Haier Four Way Valve Status
|
||||
indoor_electric_heating_status:
|
||||
name: Haier Indoor Electric Heating Status
|
||||
indoor_fan_status:
|
||||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
<<: !include common.yaml
|
||||
|
@ -1,109 +1,5 @@
|
||||
wifi:
|
||||
ssid: MySSID
|
||||
password: password1
|
||||
substitutions:
|
||||
tx_pin: GPIO17
|
||||
rx_pin: GPIO16
|
||||
|
||||
uart:
|
||||
- id: uart_haier
|
||||
tx_pin: 17
|
||||
rx_pin: 16
|
||||
baud_rate: 9600
|
||||
|
||||
climate:
|
||||
- platform: haier
|
||||
id: haier_ac
|
||||
protocol: hOn
|
||||
name: Haier AC
|
||||
wifi_signal: true
|
||||
answer_timeout: 200ms
|
||||
beeper: true
|
||||
visual:
|
||||
min_temperature: 16 °C
|
||||
max_temperature: 30 °C
|
||||
temperature_step:
|
||||
target_temperature: 1
|
||||
current_temperature: 0.5
|
||||
supported_modes:
|
||||
- 'OFF'
|
||||
- HEAT_COOL
|
||||
- COOL
|
||||
- HEAT
|
||||
- DRY
|
||||
- FAN_ONLY
|
||||
supported_swing_modes:
|
||||
- 'OFF'
|
||||
- VERTICAL
|
||||
- HORIZONTAL
|
||||
- BOTH
|
||||
supported_presets:
|
||||
- AWAY
|
||||
- BOOST
|
||||
- ECO
|
||||
- SLEEP
|
||||
on_alarm_start:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm activated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
on_alarm_end:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm deactivated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
|
||||
sensor:
|
||||
- platform: haier
|
||||
outdoor_temperature:
|
||||
name: Haier outdoor temperature
|
||||
humidity:
|
||||
name: Haier Indoor Humidity
|
||||
compressor_current:
|
||||
name: Haier Compressor Current
|
||||
compressor_frequency:
|
||||
name: Haier Compressor Frequency
|
||||
expansion_valve_open_degree:
|
||||
name: Haier Expansion Valve Open Degree
|
||||
indoor_coil_temperature:
|
||||
name: Haier Indoor Coil Temperature
|
||||
outdoor_coil_temperature:
|
||||
name: Haier Outdoor Coil Temperature
|
||||
outdoor_defrost_temperature:
|
||||
name: Haier Outdoor Defrost Temperature
|
||||
outdoor_in_air_temperature:
|
||||
name: Haier Outdoor In Air Temperature
|
||||
outdoor_out_air_temperature:
|
||||
name: Haier Outdoor Out Air Temperature
|
||||
power:
|
||||
name: Haier Power
|
||||
|
||||
binary_sensor:
|
||||
- platform: haier
|
||||
compressor_status:
|
||||
name: Haier Outdoor Compressor Status
|
||||
defrost_status:
|
||||
name: Haier Defrost Status
|
||||
four_way_valve_status:
|
||||
name: Haier Four Way Valve Status
|
||||
indoor_electric_heating_status:
|
||||
name: Haier Indoor Electric Heating Status
|
||||
indoor_fan_status:
|
||||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
<<: !include common.yaml
|
||||
|
@ -1,109 +1,5 @@
|
||||
wifi:
|
||||
ssid: MySSID
|
||||
password: password1
|
||||
substitutions:
|
||||
tx_pin: GPIO4
|
||||
rx_pin: GPIO5
|
||||
|
||||
uart:
|
||||
- id: uart_haier
|
||||
tx_pin: 4
|
||||
rx_pin: 5
|
||||
baud_rate: 9600
|
||||
|
||||
climate:
|
||||
- platform: haier
|
||||
id: haier_ac
|
||||
protocol: hOn
|
||||
name: Haier AC
|
||||
wifi_signal: true
|
||||
answer_timeout: 200ms
|
||||
beeper: true
|
||||
visual:
|
||||
min_temperature: 16 °C
|
||||
max_temperature: 30 °C
|
||||
temperature_step:
|
||||
target_temperature: 1
|
||||
current_temperature: 0.5
|
||||
supported_modes:
|
||||
- 'OFF'
|
||||
- HEAT_COOL
|
||||
- COOL
|
||||
- HEAT
|
||||
- DRY
|
||||
- FAN_ONLY
|
||||
supported_swing_modes:
|
||||
- 'OFF'
|
||||
- VERTICAL
|
||||
- HORIZONTAL
|
||||
- BOTH
|
||||
supported_presets:
|
||||
- AWAY
|
||||
- BOOST
|
||||
- ECO
|
||||
- SLEEP
|
||||
on_alarm_start:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm activated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
on_alarm_end:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm deactivated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
|
||||
sensor:
|
||||
- platform: haier
|
||||
outdoor_temperature:
|
||||
name: Haier outdoor temperature
|
||||
humidity:
|
||||
name: Haier Indoor Humidity
|
||||
compressor_current:
|
||||
name: Haier Compressor Current
|
||||
compressor_frequency:
|
||||
name: Haier Compressor Frequency
|
||||
expansion_valve_open_degree:
|
||||
name: Haier Expansion Valve Open Degree
|
||||
indoor_coil_temperature:
|
||||
name: Haier Indoor Coil Temperature
|
||||
outdoor_coil_temperature:
|
||||
name: Haier Outdoor Coil Temperature
|
||||
outdoor_defrost_temperature:
|
||||
name: Haier Outdoor Defrost Temperature
|
||||
outdoor_in_air_temperature:
|
||||
name: Haier Outdoor In Air Temperature
|
||||
outdoor_out_air_temperature:
|
||||
name: Haier Outdoor Out Air Temperature
|
||||
power:
|
||||
name: Haier Power
|
||||
|
||||
binary_sensor:
|
||||
- platform: haier
|
||||
compressor_status:
|
||||
name: Haier Outdoor Compressor Status
|
||||
defrost_status:
|
||||
name: Haier Defrost Status
|
||||
four_way_valve_status:
|
||||
name: Haier Four Way Valve Status
|
||||
indoor_electric_heating_status:
|
||||
name: Haier Indoor Electric Heating Status
|
||||
indoor_fan_status:
|
||||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
<<: !include common.yaml
|
||||
|
@ -1,109 +1,5 @@
|
||||
wifi:
|
||||
ssid: MySSID
|
||||
password: password1
|
||||
substitutions:
|
||||
tx_pin: GPIO4
|
||||
rx_pin: GPIO5
|
||||
|
||||
uart:
|
||||
- id: uart_haier
|
||||
tx_pin: 4
|
||||
rx_pin: 5
|
||||
baud_rate: 9600
|
||||
|
||||
climate:
|
||||
- platform: haier
|
||||
id: haier_ac
|
||||
protocol: hOn
|
||||
name: Haier AC
|
||||
wifi_signal: true
|
||||
answer_timeout: 200ms
|
||||
beeper: true
|
||||
visual:
|
||||
min_temperature: 16 °C
|
||||
max_temperature: 30 °C
|
||||
temperature_step:
|
||||
target_temperature: 1
|
||||
current_temperature: 0.5
|
||||
supported_modes:
|
||||
- 'OFF'
|
||||
- HEAT_COOL
|
||||
- COOL
|
||||
- HEAT
|
||||
- DRY
|
||||
- FAN_ONLY
|
||||
supported_swing_modes:
|
||||
- 'OFF'
|
||||
- VERTICAL
|
||||
- HORIZONTAL
|
||||
- BOTH
|
||||
supported_presets:
|
||||
- AWAY
|
||||
- BOOST
|
||||
- ECO
|
||||
- SLEEP
|
||||
on_alarm_start:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm activated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
on_alarm_end:
|
||||
then:
|
||||
- logger.log:
|
||||
level: DEBUG
|
||||
format: "Alarm deactivated. Code: %d. Message: \"%s\""
|
||||
args: [code, message]
|
||||
|
||||
sensor:
|
||||
- platform: haier
|
||||
outdoor_temperature:
|
||||
name: Haier outdoor temperature
|
||||
humidity:
|
||||
name: Haier Indoor Humidity
|
||||
compressor_current:
|
||||
name: Haier Compressor Current
|
||||
compressor_frequency:
|
||||
name: Haier Compressor Frequency
|
||||
expansion_valve_open_degree:
|
||||
name: Haier Expansion Valve Open Degree
|
||||
indoor_coil_temperature:
|
||||
name: Haier Indoor Coil Temperature
|
||||
outdoor_coil_temperature:
|
||||
name: Haier Outdoor Coil Temperature
|
||||
outdoor_defrost_temperature:
|
||||
name: Haier Outdoor Defrost Temperature
|
||||
outdoor_in_air_temperature:
|
||||
name: Haier Outdoor In Air Temperature
|
||||
outdoor_out_air_temperature:
|
||||
name: Haier Outdoor Out Air Temperature
|
||||
power:
|
||||
name: Haier Power
|
||||
|
||||
binary_sensor:
|
||||
- platform: haier
|
||||
compressor_status:
|
||||
name: Haier Outdoor Compressor Status
|
||||
defrost_status:
|
||||
name: Haier Defrost Status
|
||||
four_way_valve_status:
|
||||
name: Haier Four Way Valve Status
|
||||
indoor_electric_heating_status:
|
||||
name: Haier Indoor Electric Heating Status
|
||||
indoor_fan_status:
|
||||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
<<: !include common.yaml
|
||||
|
Loading…
Reference in New Issue
Block a user