esphome/tests/components/current_based/test.esp32.yaml

69 lines
1.7 KiB
YAML

i2c:
- id: i2c_ade7953
scl: 16
sda: 17
sensor:
- platform: ade7953_i2c
irq_pin: 15
voltage:
name: ADE7953 Voltage
id: ade7953_voltage
current_a:
name: ADE7953 Current A
id: ade7953_current_a
current_b:
name: ADE7953 Current B
id: ade7953_current_b
power_factor_a:
name: ADE7953 Power Factor A
power_factor_b:
name: ADE7953 Power Factor B
apparent_power_a:
name: ADE7953 Apparent Power A
apparent_power_b:
name: ADE7953 Apparent Power B
active_power_a:
name: ADE7953 Active Power A
active_power_b:
name: ADE7953 Active Power B
reactive_power_a:
name: ADE7953 Reactive Power A
reactive_power_b:
name: ADE7953 Reactive Power B
update_interval: 1s
switch:
- platform: template
id: template_switch1
optimistic: true
- platform: template
id: template_switch2
optimistic: true
cover:
- platform: current_based
name: Current Based Cover
id: current_based_cover
open_sensor: ade7953_current_a
open_moving_current_threshold: 0.5
open_obstacle_current_threshold: 0.8
open_duration: 12s
open_action:
- switch.turn_on: template_switch1
close_sensor: ade7953_current_b
close_moving_current_threshold: 0.5
close_obstacle_current_threshold: 0.8
close_duration: 10s
close_action:
- switch.turn_on: template_switch2
stop_action:
- switch.turn_off: template_switch1
- switch.turn_off: template_switch2
obstacle_rollback: 30%
start_sensing_delay: 0.8s
malfunction_detection: true
malfunction_action:
then:
- logger.log: Malfunction Detected