esphome/esphomeyaml/components/sensor/sht3xd.py

39 lines
1.5 KiB
Python

import voluptuous as vol
import esphomeyaml.config_validation as cv
from esphomeyaml.components import sensor
from esphomeyaml.const import CONF_ACCURACY, CONF_ADDRESS, CONF_HUMIDITY, CONF_MAKE_ID, CONF_NAME, \
CONF_TEMPERATURE, CONF_UPDATE_INTERVAL
from esphomeyaml.helpers import App, Application, variable
DEPENDENCIES = ['i2c']
MakeSHT3XDSensor = Application.MakeSHT3XDSensor
PLATFORM_SCHEMA = sensor.PLATFORM_SCHEMA.extend({
cv.GenerateID(CONF_MAKE_ID): cv.declare_variable_id(MakeSHT3XDSensor),
vol.Required(CONF_TEMPERATURE): sensor.SENSOR_SCHEMA,
vol.Required(CONF_HUMIDITY): sensor.SENSOR_SCHEMA,
vol.Optional(CONF_ADDRESS, default=0x44): cv.i2c_address,
vol.Optional(CONF_UPDATE_INTERVAL): cv.positive_time_period_milliseconds,
vol.Optional(CONF_ACCURACY): cv.invalid("The accuracy option has been removed and now "
"defaults to HIGH."),
})
def to_code(config):
rhs = App.make_sht3xd_sensor(config[CONF_TEMPERATURE][CONF_NAME],
config[CONF_HUMIDITY][CONF_NAME],
config[CONF_ADDRESS],
config.get(CONF_UPDATE_INTERVAL))
sht3xd = variable(config[CONF_MAKE_ID], rhs)
sensor.setup_sensor(sht3xd.Psht3xd.Pget_temperature_sensor(), sht3xd.Pmqtt_temperature,
config[CONF_TEMPERATURE])
sensor.setup_sensor(sht3xd.Psht3xd.Pget_humidity_sensor(), sht3xd.Pmqtt_humidity,
config[CONF_HUMIDITY])
BUILD_FLAGS = '-DUSE_SHT3XD'