esphome/tests/test5.yaml
Maurice Makaay c89018a431
Option to ignore CRC for EFuse MAC address (#2399)
* Accept changes as proposed by black.

* Added test and implemented optional correctly.

* Disable PHY RF full calibration (because it calls the breaking MAC retrieval function).

* Disable CONFIG_ESP32_PHY_CALIBRATION_AND_DATA_STORAGE instead of enable, dummy!

* Rename CONF_IGNORE_EFUSE_MAC_CRC to CONF_ESP32_IGNORE_EFUSE_MAC_CRC.

* Removed unused import.

* Fix ordering of constants.

* Moved all MAC address logic to core helpers.

* Use pretty MAC address for the log.

* Use standard MAC formatter function for debug component.

* Fix clang-formatting.

* Fix clang-formatting.

* Brought wording of comments in line with other function-describing comments.

* Processed code review by @OttoWinter

* Add USE_ESP32_IGNORE_EFUSE_MAC_CRC to defines.h

Co-authored-by: Maurice Makaay <mmakaay1@xs4all.net>
2021-09-30 18:08:15 +02:00

175 lines
3.4 KiB
YAML

esphome:
name: test5
build_path: build/test5
project:
name: esphome.test5_project
version: "1.0.0"
esp32:
board: nodemcu-32s
framework:
type: esp-idf
advanced:
ignore_efuse_mac_crc: true
wifi:
networks:
- ssid: 'MySSID'
password: 'password1'
api:
ota:
logger:
uart:
- id: uart1
tx_pin: 1
rx_pin: 3
baud_rate: 9600
- id: uart2
tx_pin: 17
rx_pin: 16
baud_rate: 19200
i2c:
modbus:
uart_id: uart1
flow_control_pin: 5
id: mod_bus1
modbus_controller:
- id: modbus_controller_test
address: 0x2
modbus_id: mod_bus1
binary_sensor:
- platform: gpio
pin: GPIO0
id: io0_button
tlc5947:
data_pin: GPIO12
clock_pin: GPIO14
lat_pin: GPIO15
output:
- platform: gpio
pin: GPIO2
id: built_in_led
- platform: tlc5947
id: output_red
channel: 0
max_power: 0.8
demo:
esp32_ble:
esp32_ble_server:
manufacturer: "ESPHome"
model: "Test5"
esp32_improv:
authorizer: io0_button
authorized_duration: 1min
status_indicator: built_in_led
number:
- platform: template
name: My template number
id: template_number_id
optimistic: true
on_value:
- logger.log:
format: "Number changed to %f"
args: ["x"]
set_action:
- logger.log:
format: "Template Number set to %f"
args: ["x"]
max_value: 100
min_value: 0
step: 5
select:
- platform: template
name: My template select
id: template_select_id
optimistic: true
initial_option: two
restore_value: true
on_value:
- logger.log:
format: "Select changed to %s"
args: ["x.c_str()"]
set_action:
- logger.log:
format: "Template Select set to %s"
args: ["x.c_str()"]
- select.set:
id: template_select_id
option: two
options:
- one
- two
- three
sensor:
- platform: selec_meter
total_active_energy:
name: "SelecEM2M Total Active Energy"
import_active_energy:
name: "SelecEM2M Import Active Energy"
export_active_energy:
name: "SelecEM2M Export Active Energy"
total_reactive_energy:
name: "SelecEM2M Total Reactive Energy"
import_reactive_energy:
name: "SelecEM2M Import Reactive Energy"
export_reactive_energy:
name: "SelecEM2M Export Reactive Energy"
apparent_energy:
name: "SelecEM2M Apparent Energy"
active_power:
name: "SelecEM2M Active Power"
reactive_power:
name: "SelecEM2M Reactive Power"
apparent_power:
name: "SelecEM2M Apparent Power"
voltage:
name: "SelecEM2M Voltage"
current:
name: "SelecEM2M Current"
power_factor:
name: "SelecEM2M Power Factor"
frequency:
name: "SelecEM2M Frequency"
maximum_demand_active_power:
name: "SelecEM2M Maximum Demand Active Power"
disabled_by_default: true
maximum_demand_reactive_power:
name: "SelecEM2M Maximum Demand Reactive Power"
disabled_by_default: true
maximum_demand_apparent_power:
name: "SelecEM2M Maximum Demand Apparent Power"
disabled_by_default: true
- id: battery_voltage
name: "Battery voltage2"
platform: modbus_controller
modbus_controller_id: modbus_controller_test
address: 0x331A
register_type: read
value_type: U_WORD
- platform: t6615
uart_id: uart2
co2:
name: CO2 Sensor