esphome/esphome/components/pmwcs3/sensor.py

141 lines
4.0 KiB
Python
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

import esphome.codegen as cg
from esphome import automation
import esphome.config_validation as cv
from esphome.components import i2c, sensor
from esphome.const import (
CONF_ID,
CONF_ADDRESS,
CONF_TEMPERATURE,
CONF_EC,
STATE_CLASS_MEASUREMENT,
ICON_THERMOMETER,
)
CODEOWNERS = ["@SeByDocKy"]
DEPENDENCIES = ["i2c"]
CONF_E25 = "e25"
CONF_VWC = "vwc"
ICON_EPSILON = "mdi:epsilon"
ICON_SIGMA = "mdi:sigma-lower"
ICON_ALPHA = "mdi:alpha-h-circle-outline"
pmwcs3_ns = cg.esphome_ns.namespace("pmwcs3")
PMWCS3Component = pmwcs3_ns.class_(
"PMWCS3Component", cg.PollingComponent, i2c.I2CDevice
)
# Actions
PMWCS3AirCalibrationAction = pmwcs3_ns.class_(
"PMWCS3AirCalibrationAction", automation.Action
)
PMWCS3WaterCalibrationAction = pmwcs3_ns.class_(
"PMWCS3WaterCalibrationAction", automation.Action
)
PMWCS3NewI2cAddressAction = pmwcs3_ns.class_(
"PMWCS3NewI2cAddressAction", automation.Action
)
CONFIG_SCHEMA = (
cv.Schema(
{
cv.GenerateID(): cv.declare_id(PMWCS3Component),
cv.Optional(CONF_E25): sensor.sensor_schema(
icon=ICON_EPSILON,
accuracy_decimals=3,
unit_of_measurement="dS/m",
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_EC): sensor.sensor_schema(
icon=ICON_SIGMA,
accuracy_decimals=2,
unit_of_measurement="mS/m",
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
icon=ICON_THERMOMETER,
accuracy_decimals=3,
unit_of_measurement="°C",
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_VWC): sensor.sensor_schema(
icon=ICON_ALPHA,
accuracy_decimals=3,
unit_of_measurement="cm3cm3",
state_class=STATE_CLASS_MEASUREMENT,
),
}
)
.extend(cv.polling_component_schema("60s"))
.extend(i2c.i2c_device_schema(0x63))
)
async def to_code(config):
var = cg.new_Pvariable(config[CONF_ID])
await cg.register_component(var, config)
await i2c.register_i2c_device(var, config)
if CONF_E25 in config:
sens = await sensor.new_sensor(config[CONF_E25])
cg.add(var.set_e25_sensor(sens))
if CONF_EC in config:
sens = await sensor.new_sensor(config[CONF_EC])
cg.add(var.set_ec_sensor(sens))
if CONF_TEMPERATURE in config:
sens = await sensor.new_sensor(config[CONF_TEMPERATURE])
cg.add(var.set_temperature_sensor(sens))
if CONF_VWC in config:
sens = await sensor.new_sensor(config[CONF_VWC])
cg.add(var.set_vwc_sensor(sens))
# Actions
PMWCS3_CALIBRATION_SCHEMA = cv.Schema(
{
cv.GenerateID(): cv.use_id(PMWCS3Component),
}
)
@automation.register_action(
"pmwcs3.air_calibration",
PMWCS3AirCalibrationAction,
PMWCS3_CALIBRATION_SCHEMA,
)
@automation.register_action(
"pmwcs3.water_calibration",
PMWCS3WaterCalibrationAction,
PMWCS3_CALIBRATION_SCHEMA,
)
async def pmwcs3_calibration_to_code(config, action_id, template_arg, args):
parent = await cg.get_variable(config[CONF_ID])
var = cg.new_Pvariable(action_id, template_arg, parent)
return var
PMWCS3_NEW_I2C_ADDRESS_SCHEMA = cv.maybe_simple_value(
{
cv.GenerateID(): cv.use_id(PMWCS3Component),
cv.Required(CONF_ADDRESS): cv.templatable(cv.i2c_address),
},
key=CONF_ADDRESS,
)
@automation.register_action(
"pmwcs3.new_i2c_address",
PMWCS3NewI2cAddressAction,
PMWCS3_NEW_I2C_ADDRESS_SCHEMA,
)
async def pmwcs3newi2caddress_to_code(config, action_id, template_arg, args):
parent = await cg.get_variable(config[CONF_ID])
var = cg.new_Pvariable(action_id, template_arg, parent)
address = await cg.templatable(config[CONF_ADDRESS], args, int)
cg.add(var.set_new_address(address))
return var