Z-Stack-firmware/coordinator/Z-Stack_Home_1.2/CHANGELOG.md
2019-06-19 20:09:08 +02:00

53 lines
1.4 KiB
Markdown

# 20190619
- Make source routing firmware identical to 20190315 MAX_STABILITY
# 20190611
- Attempt to improve source routing firmware
# 20190608
- One firmware doesn't seem to be feasible, also add source routing firmware
# 20190608
- Try with source routing disabled and more XDATA
# 20190523
- Re-enable source routing
# 20190515
- CC2530_CC2591 and CC2530_CC2592 only; fix transmit power (yes, again, finally)
# 20190513
- CC2530_CC2591 and CC2530_CC2592 only; fix transmit power (yes, again)
# 20190507
- CC2530_CC2591 and CC2530_CC2592 only; fix transmit power
# 20190425
- Unified firmwares, only one firmware for every device
- Increased direct children to 25 for CC2531 and 21 for CC2530
- Disabled source routing
- Decreased XDATA size
# 20190315
- Restructured repo
- Added `MAX_STABILITY` firmware
# 20190223
- Reduced memory footprint
- Increased number of routes to remember to 40
- Disabled route expiry
# 20190222
- Decreased binding and group table size to 1, allows for more memory allocated to the heap. It's not used by Zigbee2mqtt anyway.
- Reverted size of data buffers to default, a buffer full error is now properly handled by Zigbee2mqtt.
# 20190218
- Fixed `MAXMEMHEAP`
- Forward messages to endpoint 10 and 11 to 1.
# 20190217
- Forward incoming messages from all groups (not only the ones that are in the group list)
# 20190215
- Re-flash firmware without having to repair devices.
- Fixed error 17 when executing many group commands at once.