Honeywell ABP Pressure Sensors
==============================
.. seo::
:description: Instructions for setting up Honeywell ABP Pressure sensors
:image: honeywellabp.jpg
:keywords: Honeywell ABP
The ``honeywellabp`` sensor platform allows you to use your Honeywell ABP
(`website <https://sps.honeywell.com/us/en/products/sensing-and-iot/sensors/pressure-sensors/board-mount-pressure-sensors/basic-abp-series>`__,
`datasheet <https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/basic-abp-series/documents/sps-siot-basic-board-mount-pressure-abp-series-datasheet-32305128-ciid-155789.pdf?download=false>`__,
`Mouser <https://www.mouser.ca/new/honeywell/honeywell-abp-pressure-sensors/>`_) pressure and temperature sensors with ESPHome. The :ref:`SPI <spi>` is
required to be set up in your configuration for this sensor to work
.. figure:: images/honeywellabp.jpg
:align: center
:width: 50.0%
Honeywell ABP Pressure and Temperature Sensor.
.. code-block:: yaml
# Example configuration entry
sensor:
2022-03-06 23:47:05 +01:00
- platform: honeywellabp
pressure:
name: "Honeywell pressure"
unit_of_measurement: "psi"
min_pressure: 0
max_pressure: 15
temperature:
name: "Honeywell temperature"
cs_pin: GPIO5 #D5
Configuration variables:
------------------------
The values for ``min_pressure`` and ``max_pressure`` can be found in the device datasheet for the specific device. These are used to calculate
the pressure reading published by the sensor. Some sensors measure pressure in ``bar`` or ``kPa``; set ``min_pressure`` and ``max_pressure`` to
the measurement range and ``unit_of_measurement`` to the appropriate unit for your device.
- **pressure** (*Optional*): The information for the pressure sensor.
- **name** (**Required**, string): The name for the pressure sensor.
2022-04-26 00:56:19 +02:00
- **min_pressure** (**Required**, int or float): Minimum pressure for the pressure sensor, default unit ``psi``.
- **max_pressure** (**Required**, int or float): Maximum pressure for the pressure sensor, default unit ``psi``.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
Some sensors do not have temperature sensing ability, see datasheet. In some cases the sensor may return a valid temperature even though the
datasheet indicates that the sensor does not measure temperature.
- **temperature** (*Optional*): The information for the temperature sensor.
- **name** (**Required**, string): The name for the temperature sensor.
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **cs_pin** (**Required**, :ref:`SPI <spi>`): Chip select pin.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
sensor. Defaults to ``60s``.
See Also
--------
- :ref:`sensor-filters`
- :apiref:`honeywellabp/honeywellabp.h`
- :ghedit:`Edit`