Tuya Number: description of the new restore_value key for hidden datapoints (#4191)
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
This commit is contained in:
parent
24bfb50ca2
commit
f1b0f2e58f
@ -67,6 +67,9 @@ The above configurations will work fine as long as Tuya device publishes the dat
|
||||
However this is not always the case. To be able to use such "hidden" datapoints as Number, you need to specify additional ``datapoint_hidden`` configuration block.
|
||||
This block allows to specify the missing datapoint type and, optionally, the value that should be written to the datapoint at initialization.
|
||||
|
||||
TuyaMCU restores the state of all its datapoints after reboot, but with the hidden datapoints there is no way to know what their values are.
|
||||
Therefore there is also an option to store them on the ESPHome side and they will be set at initialization. To use this feature, set the ``restore_value`` yaml key to True.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
- platform: "tuya"
|
||||
@ -77,6 +80,7 @@ This block allows to specify the missing datapoint type and, optionally, the val
|
||||
datapoint_hidden:
|
||||
datapoint_type: int
|
||||
initial_value: 85
|
||||
restore_value: yes
|
||||
|
||||
Configuration variables:
|
||||
------------------------
|
||||
@ -90,6 +94,7 @@ Configuration variables:
|
||||
|
||||
- **datapoint_type** (**Required**, string): The datapoint type, one of *int*, *uint*, *enum*.
|
||||
- **initial_value** (*Optional*, float): The value to be written at initialization. Must be between ``min_value`` and ``max_value``.
|
||||
- **restore_value** (*Optional*, boolean): Saves and loads the state to RTC/Flash. Defaults to ``false``.
|
||||
|
||||
- All other options from :ref:`Number <config-number>`.
|
||||
|
||||
|