INA226 DC current and power sensor
==================================
.. seo::
:description: Instructions for setting up INA226 DC current and power sensors
:image: ina226.jpg
:keywords: ina226
The ``ina226`` sensor platform allows you to use your INA226 DC Current and Power Sensor
(`datasheet <http://www.ti.com/lit/ds/symlink/ina226.pdf>`__, `eBay`_) sensors with ESPHome.
The :ref:`I²C Bus <i2c>` is required to be set up in your configuration for this sensor to work.
.. figure:: images/ina226-full.jpg
:align: center
:width: 50.0%
INA226 DC Current and Power Sensor.
.. _eBay: https://www.ebay.com/sch/i.html?_nkw=INA226
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: ina226
address: 0x40
shunt_resistance: 0.1 ohm
max_current: 3.2A
# adc time used for both, Bus Voltage and Shunt Voltage
adc_time: 140us
adc_averaging: 128
update_interval: 60s
current:
name: "INA226 Current"
power:
name: "INA226 Power"
bus_voltage:
name: "INA226 Bus Voltage"
shunt_voltage:
name: "INA226 Shunt Voltage"
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: ina226
address: 0x40
adc_time:
voltage: 140us
current: 332us
Configuration variables:
------------------------
- **address** (*Optional*, integer): Manually specify the I²C address of the sensor. Defaults to ``0x40``.
- **shunt_resistance** (*Optional*, float): The value of the shunt resistor on the board for current calculation.
Defaults to ``0.1 ohm``.
- **max_current** (*Optional*, float): The maximum current you are expecting. ESPHome will use this to
configure the sensor optimally. Defaults to ``3.2A``.
- **adc_time** (*Optional*, :ref:`config-time` or both of the following nested options): The time in microseconds to perform a single ADC conversion.
Defaults to ``1100us``. Valid values are ``140us``, ``204us``, ``332us``, ``588us``, ``1100us``, ``2116us``,
``4156us``, ``8244us``.
- **voltage** (**Required**, :ref:`config-time`) ADC conversion time for Bus Voltage
- **current** (**Required**, :ref:`config-time`) ADC conversion time for Shunt Voltage (Current measurement)
- **adc_averaging** (*Optional*, integer): Selects ADC sample averaging count. Defaults to ``4``. Valid values are
``1``, ``4``, ``16``, ``64``, ``128``, ``256``, ``512``, ``1024``.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
Sensors
-------
The component offers four sensors. You can configure all or any subset of them. Each configured sensor
is reported separately on each update_interval. The ``name`` option is required for each sensor configured.
All other options from :ref:`Sensor <config-sensor>`.
- **current** (*Optional*): Calculated current output, Amperes.
- **power** (*Optional*): Calculated power output, Watts.
- **bus_voltage** (*Optional*): Bus voltage output (voltage of the high side contact), Volts.
- **shunt_voltage** (*Optional*): Shunt voltage (voltage across the shunt resistor) value of the sensor, Volts.
See Also
--------
- :ref:`sensor-filters`
- :doc:`ina219`
- :doc:`ina3221`
- :apiref:`ina226/ina226.h`
- `INA226 Arduino Library <https://github.com/SV-Zanshin/INA226>`__