Honeywell ABP Pressure Sensors
|
|
==============================
|
|
|
|
.. seo::
|
|
:description: Instructions for setting up Honeywell ABP Pressure sensors
|
|
:image: honeywellabp.jpg
|
|
:keywords: Honeywell ABP
|
|
|
|
The ``honeywellabp`` sensor platform allows you to use your Honeywell ABP
|
|
(`website <https://sps.honeywell.com/us/en/products/sensing-and-iot/sensors/pressure-sensors/board-mount-pressure-sensors/basic-abp-series>`__,
|
|
`datasheet <https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/basic-abp-series/documents/sps-siot-basic-board-mount-pressure-abp-series-datasheet-32305128-ciid-155789.pdf?download=false>`__,
|
|
`Mouser <https://www.mouser.ca/new/honeywell/honeywell-abp-pressure-sensors/>`_) pressure and temperature sensors with ESPHome. The :ref:`SPI <spi>` is
|
|
required to be set up in your configuration for this sensor to work
|
|
|
|
.. figure:: images/honeywellabp.jpg
|
|
:align: center
|
|
:width: 50.0%
|
|
|
|
Honeywell ABP Pressure and Temperature Sensor.
|
|
|
|
.. code-block:: yaml
|
|
|
|
# Example configuration entry
|
|
sensor:
|
|
- platform: honeywellabp
|
|
pressure:
|
|
name: "Honeywell pressure"
|
|
unit_of_measurement: "psi"
|
|
min_pressure: 0
|
|
max_pressure: 15
|
|
temperature:
|
|
name: "Honeywell temperature"
|
|
cs_pin: GPIO5 #D5
|
|
|
|
Configuration variables:
|
|
------------------------
|
|
|
|
The values for ``min_pressure`` and ``max_pressure`` can be found in the device datasheet for the specific device. These are used to calculate
|
|
the pressure reading published by the sensor. Some sensors measure pressure in ``bar`` or ``kPa``; set ``min_pressure`` and ``max_pressure`` to
|
|
the measurement range and ``unit_of_measurement`` to the appropriate unit for your device.
|
|
|
|
- **pressure** (*Optional*): The information for the pressure sensor.
|
|
|
|
- **name** (**Required**, string): The name for the pressure sensor.
|
|
- **min_pressure** (**Required**, int or float): Minumim pressure for the pressure sensor, default unit ``psi``.
|
|
- **max_pressure** (**Required**, int or float): Maximum pressure for the pressure sensor, default unit ``psi``.
|
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
Some sensors do not have temperature sensing ability, see datasheet. In some cases the sensor may return a valid temperature even though the
|
|
datasheet indicates that the sensor does not measure temperature.
|
|
|
|
- **temperature** (*Optional*): The information for the temperature sensor.
|
|
|
|
- **name** (**Required**, string): The name for the temperature sensor.
|
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
|
- All other options from :ref:`Sensor <config-sensor>`.
|
|
|
|
|
|
- **cs_pin** (**Required**, :ref:`SPI <spi>`): Chip select pin.
|
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
|
|
sensor. Defaults to ``60s``.
|
|
|
|
See Also
|
|
--------
|
|
|
|
- :ref:`sensor-filters`
|
|
- :apiref:`honeywellabp/honeywellabp.h`
|
|