mbusd/CHANGELOG.md
Victor Antonovich 4e5c7e3781 mbusd 0.5.1
2022-08-18 20:35:49 +03:00

2.8 KiB

Changelog

0.5.1 - 2022-08-18

  • Add 'reply on broadcast' feature (#75).
  • Fix for "Resource temporarily unavailable" error in tty read() (#78).
  • Add simple Dockerfile for running mbusd containerized (#79).
  • Add support for more complex serial port device names (#81).
  • Do not segfault when closing last connection (#83).
  • Fix crash due to missing logw() argument (#84).

0.5.0 - 2020-11-28

Added

  • Command-line and config options to set an TCP socket address (#53).
  • IPv6 support (#53).
  • Support for RTU broadcast messages (#61).
  • More baudrates (#62).

Fixed

  • Added online network requirements to the systemd service file (#58).
  • Take into account tty parity bit in the timing calculations (#59).
  • Show an error when trying to use unsupported baudrate (#63).

0.4.0 - 2019-07-08

Added

  • Modbus RTU Exception Forwarding (#29).
  • Handle incorrect Modbus/TCP data length header field (#31).
  • tty reconnect with an exponential backoff.

Fixed

  • Modbus: read only a single frame at a time (#43).
  • Readable socket never gets read, conn_loop degrades into busy loop (#52).

0.3.0 - 2017-12-11

Added

  • Support for reading configuration from file (-c).
  • Systemd support (thanks to Luuk Loeffen luukloeffen@hotmail.com).
  • Sysfs gpio RS-485 directional control (-y, -Y, thanks to James Jarvis jj@aprsworld.com).

Changed

0.2.3 - 2016-04-25

Fixed

  • tty mode setup on platforms with cfmakeraw available (fixes #7).

Changed

  • RTU response wait time raised to 500 ms.
  • Allow 8 bit only character size in tty mode string.

0.2.2 - 2015-12-18

Fixed

  • Function code 6 response reading error #3.

0.2.1 - 2015-06-08

Added

  • Serial port mode configuration option (-m).

0.2.0 - 2015-02-24

Added

  • RTS RS-485 transmit/receive control (thanks to Andrew Denysenko nitr0@seti.kr.ua).
  • RTU response receiving by length (thanks to Andrew Denysenko nitr0@seti.kr.ua).

Changed

  • Standard error codes for receive error (04) and timeout (0x0B).

0.1.3 - 2013-11-18

Fixed

  • Serial interface initialization under Linux.
  • x86_64 build.

Changed

  • Default RTU client response wait timeout increased to 50 ms.

Added

  • Eclipse CDT project files.

0.1.2 - 2003-09-26

Fixed

  • Compilation under CYGWIN.

0.1.1 - 2003-09-13

Initial release